Trouble shooting

Normal
Performance
inspection

Noise is heard

Phenomenon

Cause or check points

The system 

immediately.

Smells are

generated.

Mist or steam are 

Multiple

check

Poor cooling

When unit is stopped, it won't restart 

elapsed to protect the system.
When the electric plug is pulled out 
and reinserted, the protection circuit 

During unit operation or at stop, 
a swishing or gurgling noise may 

(This noise is generated by

refrigerant flowing in the system.)

During unit operation, a cracking

noise may be heard.This noise is

temperature changes.

Should there be a big noise from

 filter may be too dirty.

This is because the system 
circulates smells from the interior

During COOL or DRY operation, 

This is due to the sudden cooling

Is power plug inserted?
Is there a power failure?
Is fuse blownout?

Is the air filter dirty?

Are there any obstacles before 

Is temperature set correctly?
Are there some doors or 

Is there any direct sunlight
through the window during the 

Are there too much heat sources
or too many people in the room 

In dry mode, fan 
speed can’t be 
changed.

In DRY mode, when room temperature

2

o

C,unit will run

regardless of FAN setting.

during cooling operation?

cooling operation?(Use curtain)

 windows left open?

 inlet and outlet?

Normally it should be cleaned 
every 15 days.

intermittently at LOW speed 

becomes lower than temp.

indoor unit may blow out mist.

of indoor air.

air such as the smell of furniture,

paint, cigarettes.

air flow in unit operation, air 

generated by the casing expanding

or shrinking because of

be heard.At first 2-3 minutes after

unit start, this noise is more noticeable. 

will work for 3 minutes to protect the

air conditioner.

immediately until 3 minutes have

 Cautions

3. If the fuse of indoor unit on PC board is

it with the type of T. 3.15A/ 250V

outdoor

  broken,change it with the type of T.25A/250V

     Do not obstruct or cover the ventilation

conditoner.Do not put fingers

inlet/outlet and swing louver.

     Do not allow children to play with the air conditioner

case should children be allowed to sit on the outdoor unit.

The refrigerating circuit is leak-proo f.

1.Applicable ambient temperature range:

 Specifications

The machine is adaptive in following situation

11 .The power plug and connecting cable

acquired the local 

2. If the power supply cord is damaged, it must be replaced 

manufacturer

qualified

   person.

4. The wiring method should be in line with

   the local wiring

5. After installation, the power plug should

   be easily reached.

6. The waste battery should be disposed

   properly.

7. The appliance is not intended for use

 persons

    without supervision.

8. Young children should be supervised

with

    the appliance.

9. Please employ the proper power plug,

cord.

12.In order to protect the units,please turn

30 seconds

     later, cutting off the power.

10. A breaker should be incorporated into
      should be

      contacts should be not less than

      3mm.

Cooling

Indoor

Maximum:D.B/W.B

Maximum:D.B/W.B

D.B

Maximum:D.B

D.B

Minimum:D.B/W.B

Maximum:D.B/W.B

Minimum:D.B/W.B

Outdoor

Indoor

Outdoor

Heating

32

o

C/23

o

C

24

o

C/18

o

C

o

C/-8

o

C

43

o

C/26

o

C

18

o

C

27

o

C

21

o

C/15

o

C

Outdoor

Maximum:D.B/W.B

Minimum:D.B

24

o

C/18

o

C

-15

o

C

(INVERTER)

0

o

C

7

-

13.Please don't insert any sensor on 3-way 

     stop valve pipe

Minimum:

Minimum:

grille of the air 

or any other things into the 

.In no

   or its service agent or a similar 

   broken,please

. If the fuse of 

standard.

by young children or

    to ensure that they

    which fit into the 

      fixed wiring. The 

      all-pole switch and the distance 

must have

     off the A/C first, 

 fitting. 

Before asking for service, check the following 
first.

blown out.

does not restart

by the 

change

unit is

infirm

do not play

    power supply 

      breaker 

      between

      its two 

attestation.

and at least 

X

0.415

0.317

HSU-09HRA103/R2

HSU-12HRA103/R2

Summary of Contents for HSU-12HR03

Page 1: ...ONDITIONER OPERATION MANUAL Keep this operation manual for future reference Contents 2 3 6 7 1 CAUTIONS PARTS AND FUNCTIONS OPERATION MAINTENANCE TROUBLE SHOOTING HSU 09HR03 R2 DB HSU 12HR03 R2 DB HSU...

Page 2: ...other buttons be disabled Press it once again lock will be cancelled 29 LOCK HEAT 17 Signal sending display 2 LIGHT button Control the lightening and the indoor 2 11 12 13 14 15 16 17 18 19 20 21 22 2...

Page 3: ...when the room normal operation your finger from the switch the cooling Continue to press the test operation switch for more than 5 seconds After you hear the Pi sound twice release Test operation swi...

Page 4: ...igher than temp setting so that room temperature won t be too low for your sleep 1 hours after SLEEP mode starts temp will become 2 lower than temp setting After another 1 hours temp decrease by 2 fut...

Page 5: ...pplied with the product The filled out label must be adhered in the proximity of the product charging port e g onto the inside of the stop value cover A contains fluorinated greenhouse gases covered b...

Page 6: ...ated in the right side of the indoor unit using vacuum cleaner or flaping them lightly otherwise its performance will be affected the cool and dry conditions For Smart Use of The Air Conditioner Repla...

Page 7: ...NT PROHIBITION PROHIBITION PROHIBITION PROHIBITION Do not start or stop the operation by disconnecting Do not channel the air flow directly at people especially at infants or the aged Do not try to re...

Page 8: ...he type of T 3 15A 250V outdoor broken change it with the type of T 25A 250V Do not obstruct or cover the ventilation conditoner Do not put fingers inlet outlet and swing louver Do not allow children...

Reviews: