background image

Operation

Set clock correctly before starting TIMER operation.
1.After unit starts, select your desired operation mode.
2.Press TIMER button to change TIMER mode. Every
time the button is pressed, display changes as follows:
Remote controller:

BLANK

TIMER ON

TIMER OFF

TIMER ON-OFF

Then select your desired TIMER mode (TIMER ON or
TIMER OFF or TIMER ON-OFF). "        "or "       "will flash.
3.Press TIME+ /TIME- button to set time.
It can be adjusted within 24 hours.
4.After setting correct time,  press SET button to confirm
"        "or"       " on the remote controller stops flashing.
5.Cancel TIMER mode
Just press TIMER button several times until TIMER mode 
disappears.
Hints:
After replacing batteries or a power failure happens, time
setting should be reset.
Remote controller possesses memory function,when use
TIMER mode next time,  just press SET button after mode
selecting if time setting is the same as previous one.
According to the Time setting sequence of TIMER ON or
TIMER OFF, either Start-Stop or Stop-Start can be 
achieved.

 Timer On/Off  On-Off Operation 

CE

All the products are in conformity with the following 
European provision:
- Low Voltage Directive 73/23/EEC
- Low Voltage Directive 2006/95/EC
-Electomagnetic CompatibilitY 89/336/EEC
-Electomagnetic CompatibilitY 2004/108/EC 

ROHS

The products are fulfilled with the requirements in the 
directive 2002/95/EEC of the European parliament and of
council on the Restriction of the use of Certain Hazardous
Substances in Electrical and Electronic Equipment (EU 
RoHS Directive)

WEEE

DISPOSAL REQUIREMENTS:

Your air conditioning product is marked with this
symbol.This means that electrical and electronic
products shall not be mixed with unsorted 
household waste. Do not try to dismantle the 
system yourself : the dismantling of the air

EUROPEAN REGULATIONS
CONFORMITY FOR THE MODELS

1

1+2=

kg

R410A

2

kg

2=

1=

B

C

D

F

E

kg

A

This product contains fluorinated greenhouse gases covered by 
the Kyoto Protocol. Do not vent into the atmosphere.
Refrigerant type:R410A
GWP* value:1975
GWP=global warming potential
Please fill in with indelible ink,
• 1      the factory refrigerant charge of the product
• 2      the additional refrigerant amount charged in the field and
• 1+2  the total refrigerant charge
on the refrigerant charge label supplied with the product.
The filled out label must be adhered in the proximity of the product
charging port (e.g. onto the inside of the stop value cover).
A  contains fluorinated greenhouse gases covered by the Kyoto 
Protocol
B  factory refrigerant charge of the product: see unit name plate
C   additional refrigerant amount charged in the field
D   total refrigerant charge
E   outdoor unit
F   refrigerant cylinder and manifold for charging 

IMPORTANT INFORMATION REGA-
RDING THE REFRIGERANT USED

In accordance with the directive 

2002/96/CE

of the European

parliament, herewith we inform the consumer about the dis-
posal requirements of the electrical and electronic products.

conditioning system,treatment of the refrigerant, of oil and of
other part must be done by a qualified installer in 

accordance

with relevant local and national legislation. Air conditioners 
must be treated at a specialized treatment facility for reuse, 
recycling and recovery. By ensuring this product is disposed 
of correctly, you will help to prevent potential negative cons-
equences for the environment and humen health. Please 
contact the installer or local authority for more information. 
Battery must be removed from the remote controller and dis-
posed of separately in accordance with relevant local and 
nationl legislation.

Contains fluorinated greenhouse gases
covered by the Kyoto Protocol

5

 Healthy airflow Operation

1.Press ON/OFF to starting

Setting the comfort work conditions.

2.The setting of healthy airflow function

1).Press the button of healthy airflow,        appears on the
display. Horizontal airflow sending. Avoid the airflow

blows direct to the body.

2).Press the button of healthy airflow again,      appears on

the display. Downward airflow sending. Avoid the airflow 

Note:

1.After setting the healthy airflow function, the position 

 grill is fixed.

4.In cooling and dry, using the air conditioner for a long 

time under the high air humidity, condensate water may
occur at the grille .

3.The cancel of the healthy airflow function

Press the button of healthy airflow again,  the unit goes on 

working under the condition before the setting of healthy

airflow function.

Notice: Do not direct the flap by hand. Otherwise, the
grille will run incorrectly. If the grille is not run correctly, stop
for a minute and then start, adjusting by remote 
controller.

blows direct to the body.

2.In heating, it is better to select the
3.In cooling, it is better to select the 

mode.

mode.

Summary of Contents for HSU-12HR03

Page 1: ...ONDITIONER OPERATION MANUAL Keep this operation manual for future reference Contents 2 3 6 7 1 CAUTIONS PARTS AND FUNCTIONS OPERATION MAINTENANCE TROUBLE SHOOTING HSU 09HR03 R2 DB HSU 12HR03 R2 DB HSU...

Page 2: ...other buttons be disabled Press it once again lock will be cancelled 29 LOCK HEAT 17 Signal sending display 2 LIGHT button Control the lightening and the indoor 2 11 12 13 14 15 16 17 18 19 20 21 22 2...

Page 3: ...when the room normal operation your finger from the switch the cooling Continue to press the test operation switch for more than 5 seconds After you hear the Pi sound twice release Test operation swi...

Page 4: ...igher than temp setting so that room temperature won t be too low for your sleep 1 hours after SLEEP mode starts temp will become 2 lower than temp setting After another 1 hours temp decrease by 2 fut...

Page 5: ...pplied with the product The filled out label must be adhered in the proximity of the product charging port e g onto the inside of the stop value cover A contains fluorinated greenhouse gases covered b...

Page 6: ...ated in the right side of the indoor unit using vacuum cleaner or flaping them lightly otherwise its performance will be affected the cool and dry conditions For Smart Use of The Air Conditioner Repla...

Page 7: ...NT PROHIBITION PROHIBITION PROHIBITION PROHIBITION Do not start or stop the operation by disconnecting Do not channel the air flow directly at people especially at infants or the aged Do not try to re...

Page 8: ...he type of T 3 15A 250V outdoor broken change it with the type of T 25A 250V Do not obstruct or cover the ventilation conditoner Do not put fingers inlet outlet and swing louver Do not allow children...