background image

Before disposing an old air conditioner that
goes out of use, please make sure it's inop-
erative and safe. Unplug the air conditioner
in order to avoid the risk of child entrapment.

It must be noticed that air conditioner system
 contains refrigerants, which require speciali-
zed waste disposal. The valuable materials
contained in an air conditioner can be recycled
.Contact your local waste disposal center for
proper disposal of an old air conditioner and
contact your local authority or your dealer if
you have any question. Please ensure that
the pipework of your air conditioner does not
get damagedprior to being picked up by the
relevant waste disposal center, and contribute
to environmental awareness by insisting on an
appropriate, anti-pollution method of disposal.

Cautions

Disposal of the old air conditioner

All the packaging materials employed in the
package of your new air conditioner may be
disposed without any danger to the
environment.

The cardboard box may be broken or cut into
smaller pieces and given to a waste paper
disposal service. The wrapping bag made of
polyethylene and the polyethylene foam pads

contain no fluorochloric hydrocarbon.

All these valuable materials may be taken to
a waste collecting center and used again after
adequate recycling.

Consult your local authorities for the name
and address of the waste  materials collecting
centers and waste paper disposal services
nearest to your house.

Disposal of the packaging of your
new air conditioner

Before starting the air conditioner, read the
information given in the User's Guide caref-
ully. The User's Guide contains very impor-
tant observations relating to the assembly,
operation and maintenance of the air
conditioner.

The manufacturer does not accept respon-
sibility for any damages that may arise due
to non-observation of the following
instruction.

    Damaged air conditioners are not to be
put into operation. In case of doubt, consult
your supplier.

   Use of the air conditioner is to be carried
out in strict compliance with the relative
instructions set forth in the User's Guide.

   Installation shall be done by professional
people, don't install unit by yourself.

    For the purpose of the safety,the air con-
ditioner must be properly grounded in acco-
rdance with specifications.

    Always  remember  to unplug the air
conditioner before openning inlet grill. Never
unplug your air conditioner by pulling on
the power cord. Always grip plug firmly and
pull straight out from the outlet.

    All electrical repairs must be carried out
by qualified electricians. Inadequate repairs
may result in a major source of danger for
the user of the air conditioner.

Safety Instructions and Warnings

     Do not damage any parts of the air
conditioner that carry refrigerant by piercing
or performating the air conditioner's tubes
with sharp or pointed items, crushing or
twisting any tubes, or scraping the coatings
off the surfaces. If the refrigerant spurts
out and gets into eyes, it may result in
serious eye injuries.

1

Summary of Contents for HSU-09RC03/R2(DB)

Page 1: ...Please read this operation manual before using the air conditioner HSU 09RC03 R2 DB HSU 12RC03 R2 DB HSU 18RC03 R2 DB HSU 22RC03 R2 DB SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL...

Page 2: ...disposal services nearest to your house Disposal of the packaging of your new air conditioner Before starting the air conditioner read the information given in the User s Guide caref ully The User s G...

Page 3: ...cord is damaged it must be replaced by the manufacturer or its service agent or a similar qualified person 4 The wiring method should be in line with the local wiring standard 5 After installation the...

Page 4: ...ease call Sales Service Shop for the Installation Do not attempt to install the air conditioner by yourself because improper works may cause electric shock fire water leakage lnstallation in a inadequ...

Page 5: ...ially at infants or the aged Do not try to repair or reconstruct by yourself Do not use for the purpose of storage of food art work precise equipment breeding or cultivation CAUTION Take fresh air occ...

Page 6: ...etgrille AirPurifyingFilter inside Anion generator inside Vertical louver Use remote controller to adjust up and down air flow Don t adjust it manually Horizontal louver Air filter inside Outlet Power...

Page 7: ...on and extinguished 31 CODE Used to select CODE A or B with a press A or B will be displayed on LCD Please select A without special explanation 1 HEALTH button Used to set healthy operation 2 HOUR but...

Page 8: ...y obstacle as well Don t throw or knock the remoter controller When electronic started type fluorescent lamp or change over type fluorescent lamp or wireless telephone is installed in the room the rec...

Page 9: ...rk the health lamp lights up but the anion generator does not release anion Operation Health Operation Remote controller 1 Unit start Then set up the comfortable working state Link with electronic pow...

Page 10: ...pt Timer Sleep Power Soft and Health airflow 2 Select operation mode Press FAN button For each press fan speed changes as follows Press MODE button For each press operation mode changes as follows Rem...

Page 11: ...ler Remote controller Then Select COOL operation Press TEMP button Every time the button is pressed temp setting increase 1 C if kept depressed it will increase rapidly Every time the button is presse...

Page 12: ...ncrease 1 C if kept depressed it will increase rapidly Every time the button is pressed temp setting increase 1 C if kept depressed it will decrease rapidly Select a desired temperature 4 Fan speed se...

Page 13: ...fan speed changes as follows Press MODE button For each press operation mode changes as follows Remote controller Remote controller Then Select FAN operation 3 Fan speed selection 4 Unit stop About F...

Page 14: ...TEMP button Every time the button is pressed temp setting increase 1 C if kept depressed it will increase rapidly Every time the button is pressed temp setting increase 1 C if kept depressed it will...

Page 15: ...ent operation modes remote controller COOL DRY FAN remote controller remote controller The vertical flap will swing according to the above positions HEAT AUTO Horizontal louvers Pos 1 Pos 2 Pos 3 Pos...

Page 16: ...creases 2O C Decreases 2O C 1 hr Sleep Operation 2 3 In HEAT mode 1 hours after SLEEP mode starts temp will become 2 O C lower than temp setting After another 1 hours temp decrease by 2 O C further Af...

Page 17: ...as follows Remote controller BLANK TIMER ON TIMER OFF TIMER ON OFF Then select your desired TIMER mode TIMER ON or TIMER OFF or will flash 3 Time setting Press HOUR button Every time the button is pr...

Page 18: ...HOUR button Every time the button is pressed time setting increases 1 min if kept depressed it will increase rapidl Every time the button is pressed time setting decreases 1 min if kept depressed it...

Page 19: ...SOFT button twice POWER SOFT disappears In SOFT operation mode fan speed automatically takes LOW changes as follows Stop the display at SOFT BLANK POWER Press POWER SOFT button Every time the button i...

Page 20: ...flow blows direct to the body Note 1 After setting the health airflow function the position of in and outlet grills is fixed 2 In heating it is better to select the mode 3 In cooling it is better to s...

Page 21: ...operation the system automatically selects the operation modes cooling or heating according to the room temperature Test operation Test operation switch is the same as emergency switch Use this switch...

Page 22: ...eration prevent the penetration of direct sunlight with curtain or blind Close doors and windows during operation If the unit is not to be used for a long time turn off the power supply main switch OF...

Page 23: ...at the filter is completely fixed behind the stopper If the right and left filters are not attached correctly that may cause defects Remote Controller Do not use the following for cleaning Do not use...

Page 24: ...g intermediary accessories with machine will be used based on real situation The bacteria killing medium air purifying filter is available for a long time and needn t to be changed But it must be noti...

Page 25: ...for 2 3 hours Put off the power supply cord Take out the batteries from the wireless remote controller Cleaning the body To prevent breeding mold or bad smell be sure to operate at the designated tem...

Page 26: ...g insert the plug of the power supply cord into the outlet completely In case of suing exclusive circuit breaker switch on the circuit breaker NO WET HAND EARTHING Operation without filter may cause t...

Page 27: ...ve elapsed to protect the system When the electric plug is pulled out and reinserted the protection circuit will work for 3 minutes to protect the air conditioner During unit operation or at stop a sw...

Reviews: