background image

Floor fixing dimensions

of the outdoor unit

(Unit:mm)

HSU-12LE04

Floor fixing dimensions

of the outdoor unit

(Unit:mm)

HSU-18LE04

140

500

140

256

HSU-22LE04

For 22

15.88mm(5/8")

9.52mm(3/8")

113.5

583

113.5

5.

91

3

Fixing of outdoor unit

Indoor Unit

Selection of Installation Place

Power Source

Selection of pipe

Outdoor Unit

Fix the unit to concrete or block with bolts(   10mm) and nuts firmly and horizontally.

When fitting the unit to wall surface, roof or rooftop, fix a supporter surely with nails
or wires in consideration of earthquake and strong wind.
If vibration may affect the house, fix the unit by attaching a vibration-proof mat.

Place, robust not causing vibration, where the body can be supported

sufficiently.

Place, not affected by heat or steam generated in the vicinity, where

inlet and outlet of the unit are not disturbed.

Place, possible to drain easily, where piping can be connected with the

outdoor unit.

Place, where cold air can be spread in a room entirely.

Place, nearby a power receptacle, with enough space around. (Refer

to drawings).

Place where the distance of more than lm from televisions, radios,

wireless apparatuses and fluorescent lamps can be left.

In the case of fixing the remote controller on a wall, place where the

indoor unit can receive signals when the fluorescent lamps in the room

are lightened.

Place, which is less affected by rain or direct sunlight and is

sufficiently ventilated.

Place, possible to bear the unit, where vibration and noise are

not increased.

Place, where discharged wind and noise do not cause a

nuisance to the neighbors.

Place, where a distance marked       is available as illustrated

in the above figure.

Before inserting power plug into receptacle, check the voltage without fail. The power source is the same as the corresponding name plate.
Install an exclusive branch circuit of the power.
A receptacle shall be set up in a distance where the power cable can be reached. Do not extend the cable by cutting it.

To this unit, both liquid and gas pipes shall be insulated
as they become Iow temperature in operation.
Use optional parts for piping set or pipes covered with
equivalent insulation material.

2

Floor fixing dimensions

of the outdoor unit

(Unit:mm)

HSU-09LE04

Liquid pipe ( )

For  07 09

6.35mm(1/4")

Gas pipe   (    ) 9.52mm(3/8")

For 12,18

6.35mm(1/4")

12.7mm(1/2")

140

140

415

280

FJT-12L

FJT-18L

FJT-24L

HSU-07LD03

For  24

15.88mm(5/8")

6.35mm(1/4")

Summary of Contents for HSU-09LE04

Page 1: ...Drain hose Heating insulating material Piping hole cover Arrangement of piping directions Rear left Rear right Left Below Right The marks from to in the figure are the parts numbers The distance betw...

Page 2: ...rom televisions radios wireless apparatuses and fluorescent lamps can be left In the case of fixing the remote controller on a wall place where the indoor unit can receive signals when the fluorescent...

Page 3: ...ticle When the mounting plate is first fixed for the position of wall hole Fix to side bar and lintel a mounting bar Which is separately sold and then fasten the plate to the fixed mounting bar Make a...

Page 4: ...aslant from the underside and then put it down perpendicularly Remove terminal cover at right bottom corner of indoor unit then take off wiring cover by removing its screws When connecting the cable a...

Page 5: ...e sure the cables have been properly inserted and tightened After the cable connection never fail to fasten the connected cable with the wiring cover Note When connecting the cable confirm the termina...

Page 6: ...operation can not be carried out and controller may be damaged If the drain elbow is used please attach it as figure Note Only for heat pump unit Drawing for the installation of indoor and outdoor un...

Page 7: ...onal amount 5m 7m No need 40g 10m 100g for 7k 9k 12k 18k Push the air out of the indoor unit and piping as followes 1 Remove the valve cap on 2 way valve in outdoor unit 2 Loosen by 1 2 turn the flare...

Page 8: ...nfirm that drainage is carried out surely to outdoor In case that the attached drain hose is in a room please apply heat insulation to it without fail Please kindly explain to our customers how to ope...