![background image](http://html1.mh-extra.com/html/haier/hrf328w2/hrf328w2_service-manual_4726817025.webp)
SERVICE MANUAL
Model: HRF328\368
25
Issue 2015-7-18
Rev.
Ref 1507S002V1
Check if each connector of starter
overload protector, run capacitor is
in good condition?
Check each connectors of the starter overload
protector and run capacitor, ensure each contact is
in good condition, then power on and retest the
machine.
YES
Check if the compressor is normal?
Test the resistance parameter of the compressor; if it is
ZERO, inner winding is short circuit, if it is infinite, inner
winding is break circuit
Compressor
accessories
failure
NOT
NORMAL