The cabinet and outer tub component
1) Method of disassembling
A.Loosen the two motor bolt unit to dismantle the motor. To adjust the
tension of the belt, loosen the bolts and move the motor left and right.
B.Loosen the four fastening screws to dismantle the delivery shield.
C.Loosen the three fastening bolts to dismantle the drain motor.
D.In dismantling the drain valve, first loosen the screws, then rotate
combination part with the drain hose, overflow hose and outer tub
slowly to make it loose. Then dismantle the drain valve.
E.In dismantling the inner tub, first take off the outer tub cover, then
dismantle the pulsator, finally dismantle the inner tub. Handle with care
when taking the inner tub off from the outer tub.
2) Points of attention in assembly
In installation of the drain valve, please smear a piece of 801 glue at
the connection part between the drain valve and outer tub and between
the overflow hose and drain hose to guarantee that the drain valve will
not leak.
In fastening the screws, make it tight without sliding.
Take care not to scratch the cabinet and influence the appearance of
the Machine.
4-8-2 Points of attention in assembly
Fix the wiring in the control panel seat to its original position. Do not
make it touch sharp corner and mobile position. The space surrounding
the computer sequencer is rather narrow. Please dispose it carefully
and do not make the transformer press the wires.
Confirm that the control panel seat is installed to proper position of
the cabinet. Pay attention on the adjusting of the gap between the
control panel seat and the cabinet.
Service Manual
Model No: HLP21N
Issue
Rev.
-15-