Range Hood

Model:HIH-T895 

Summary of Contents for HIH-T895

Page 1: ...Range Hood Model HIH T895 ...

Page 2: ......

Page 3: ...hange at any time For current details about model and specification availability in your country please contact your local Haier dealer Introduction 2 Safety and warnings 3 Installation instructions 4 About your rangehood 11 Operating instructions Control panel 12 Cleaning and maintenance 13 Troubleshooting 15 Warranty 17 2 3 4 5 6 7 8 1 ...

Page 4: ......

Page 5: ...2 INTRODUCTION Thank you for purchasing a Haier range hood This user guide explains the features and functions and will help you get the most out of your range hood We hope you enjoy your new range hood ...

Page 6: ......

Page 7: ...d into a hot flue being used to vent appliances burning gas or other fuels Do not flambe directly under the range hood Children and persons with reduced physical sensory or mental capabilities shall not use the range hood without supervision This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and ...

Page 8: ...llector 1 Self tapping screw ST4 x 12 4 Duct 180 2 Expansion plug 8 x 40 7 Self tapping screw ST3 x 8 2 Cross recessed pan head screw M4 x 20 8 Mounting screw 5 x 50 7 Range hood 1 Wall plate 1 The screws and plugs are to be used in concrete or brick walls only Different fixings will be required for other types of wall construction Range Hood Model HIH T895 Haier ...

Page 9: ...TOIN INSTRUCTIONS Namesof principal components Fan Oil filter assembly Hand tightened nut Inner decorative cover Sealing ring Outer decorative cover Top cover Volute Check valve assembly Main housing LED Light 1 ...

Page 10: ...t min 610 max 990 B Overall width of product 895 C Overall depth of product 520 D Height of canopy 80 E Width of flue 375 F Depth of flue 320 G Centre of ducting to left edge of product 370 H Centre of ducting to back edge of product 170 I Outside diameter of check valve assembly 185 IMPORTANT A F E B G C H I A D max min Actual product dimensions may vary by 2 mm ...

Page 11: ... hood MINIMUM CLEARANCES mm J Height top of gas cooktop to base of rangehood min 650 max 700 K Height of rangehood installation if ducted through the ceiling if ducted through the rear min 610 min 990 L Depth of rangehood installation 533 K J L ...

Page 12: ... to prevent hazards such as electric shocks or gas leaks Temporarily mark the height of the bottom of the range hood and the centre of the cooktop on the wall according to the information given on page 8 2 Install the wall plate Fit the expansion plugs into the holes Secure the wall plate to the wall using the mounting screws 3 Install the decorative cover holder if inner decorative cover extensio...

Page 13: ...9 INSTALLATION INSTRUCTIONS 4 Install the supports Attach the supports to the back of the range hood as shown in Fig 3 Fig 2 Fig 3 ...

Page 14: ...niversal ducting hose into the recess of the check valve and secure to the check valve assembly with the self tapping screws Connect the other end of the ducting hose to a shared flue or external wall hole venting performance The number of bends should be minimised Flexible ducting should be stretched tight and trimmed to suit the installation 9 Extend the inner decorative cover if inner decorativ...

Page 15: ...e Universal Ducting Hose Net Weight Odour Removal Efficiency Grease Separation Off Power Standby Power Total Pressure Efficiency LED Lamp Technical Data Input Power 3 W Rated Voltage 12 V Cap Type Buckle Size 220 mmX58 mm 219 W 222 W 22 5 m min Rated Voltage 230V Rated Frequency 50 Hz At Air Flow of 7 m min 260 Pa Outer Diameter 180 mm Length 1500 mm 58 dB A 90 2 W 23 ...

Page 16: ...econds Function 2 This key is also for Hood Hob Connectivity function It needs to be matched up and work together with Haier Gas Hob which also has the same Hood Hob Connectivity function 1 Match up While the Range Hood is at standby state long press this button for 5 seconds after a ding dong sound the key start to blink for 15 seconds within this 15 seconds Rotate the Knob of the Hob another Din...

Page 17: ...l receptacle as necessary When the oil receptacle reaches the mark it should be removed promptly to avoid overflow Pull the oil receptacle straight out to detach r e v o C l i O e h t m o r f t i Empty the oil receptacle The oil receptacle should be washed in warm water with detergent do not use corrosive chemicals To replace the oil receptacle slide it into the slot on the and ensure it is pushed...

Page 18: ...the screws holding the main housing cover plate and remove the cover plate Loosen the screws holding the intake ring and remove the intake ring Twist the nut in a clockwise direction to remove the fan Take particular care when cleaning the fan that the clips on the blades are not moved or lost as this will imbalance the fan and cause vibration of the entire rangehood leading to increased noise To ...

Page 19: ...r sales service centre Product vibrates Main unit is not securely fastened to wall Check that the main unit is fastened securely Fan is not well fitted Fit the fan properly Fan is damaged Replace the fan please contact the service centre Hand tightened nut is loose Poor suction too wide during use or are closed Open or close doors and windows as necessary to ensure venting performance Range hood b...

Page 20: ...oblem by following the above prompts or one of the situations below occurs please unplug the range hood straight away and contact our after sales service centre 1 The range hood runs unevenly when turned on 2 The range hood makes an unusual noise during operation 3 Strange odours heat or smoke are discovered or other unusual circumstances not mentioned above occur The following phenomenon is not a...

Page 21: ...itution of original components with spurious non genuine components attacked by household pest rodents fire flood earthquake lightning and or any other act of God natural calamities c The product is shitted outside India 12 a For any service under this warranty beyond city town municipal limits from the Company authorized service center a fixed charge of Rs 100 will be collected from the customer ...