After installation is completed, the following method must be used to determine if the exhaust system is acceptable:

Although vertical orientation of the exhaust system is acceptable, certain extenuating circumstances could affect the 
performance of the dryer:

The exhaust system should be inspected and cleaned a minimum of every 18 months with normal usage. The more the
 dryer is used, the more often you should check the exhaust system and vent hood for proper operation.

1. Connect an inclined or digital manometer between the dryer and the point the exhaust connects to the dryer.
2. Set the dryer timer and temperature to air fluff (cool down) and start the dryer.
3. Read the measurement on the manometer.
4.The system back pressure MUST NOT be higher than 0.75  inches of water column. If the system back pressure is less 
than 0.75 inches of water column, the system is acceptable. If the manometer reading is higher than 0.75 inches of water 
 column, the system is  too restrictive and the installation is unacceptable.

1. Only the rigid metal duct work should be used.
2. Venting  vertical  through  a  roof  may  expose  the  exhaust  system  to  down drafts causing an increase in vent restriction.
3. Running  the  exhaust system through an uninsulated  area  may cause condensation and faster accumulation of lint.
4. Compression or crimping of the exhaust system will cause an increase in vent restriction.

C

C

L

ocation of your dryer 

R

ough-in dimensions 

L

R

Do not install your dryer:

Installation in recess or closet:

      In an area exposed to dripping water or outside water conditions.

      Ia dryer installation in a bedroom, bathroom, recess or closet, must be exhausted outdoors.

      In an area where it will come in contact with curtains drapes, or anything that will obstruct of combustion and 
      ventilation air.

      Your dryer needs the space around it for proper ventilation.

      On carpet, floor must be solid with a maximum slope of inch (2.54 cm).

      A minimum of 120 square inches(774.2 square cm) of opening, equally divided at the top and bottom of the door, is 
required. Air openings are required to be unobstructed when a door is installed. The full length of the door is acceptable.

REAR VIEW

SIDE VIEW

DIMENSIONS

DOOR OPEN 90

28

1/4''

(71.8 cm)

50 3/5''

(128.5 cm)

Summary of Contents for Ginesis HLF103Q

Page 1: ... 1 3 Circuit diagram 2 4 Names of parts 2 5 Usage of the operation knobs 3 6 Products brief and new features 5 7 Key point in installation adjustment and disassembly 7 8 Analysis of the common breakdowns 11 1 Specification list 1 2 Dimensional drawing 1 3 Circuit diagram 2 4 Names of parts 2 5 Usage of the operation knobs 3 6 Products brief and new features 5 7 Key point in installation adjustment...

Page 2: ... to the laundries automatically the time for setting 0 180 min User s manual product registration card Rated voltage rated frequency Rated dry capacity Rated power consumption in drying Rated input consumption of motor Manual setting Automatic Accessories Dimension Weight kg 4800W 379W 1 Specification list 2 Dimensional drawing 686 718 1080 ...

Page 3: ...mes of parts control plate front plate front door control panel shutter exhaust duct back baffle nameplate cabinet adjustable foot thread protected board I thread protected board II fasten button whisk leaf barrel roll lint filter lock body ...

Page 4: ...y Cycles Touch Up Medium Low High High Medium Low High High Medium Low High High Medium Air Dry Low High High Delicate Heavy Duty Towels Cotton Cycles More Dry Less Dry Dry Cool down Cycle completed Extend trumble Customer Louder Softer Off Cycle Signal Bulky Items Casual Delicate On Off Wrinkle Care Timed Cycles More Time Less Time Auto Dry Rack Dry Timed Dry Time Remaining Min Time On Hour Delay...

Page 5: ... start of the cycle If no delay the wrinkle saver indicator is off and remaining time indicator is on The nixie display indicates remaining time of non reserved program If setting Wrinkle Saver in standby status the nixie display indicates 3 hr which will increase by 1 hr with each pressing until 24 and return to 3 If keep pressed for 1 5 s nixie display indicated value will increase continuously ...

Page 6: ...dries The air intake and exhaust system has high degree of tightness and improves the thermal efficiency 5 Heating system The electric heating thread installed on the heating plate at the rear of the cabinet is the heating source of the appliance The exchanging of cold and hot air is realized by it The heating power of the electric heating thread is about 4500W It can raise the air temperature rap...

Page 7: ...ear corners of your dryer After properly placing your dryer or by turning them counterclockwise to lower your dryer Leveling legs can be adjusted by turning them clockwise to raise your dryer or by turning them counterclockwise to lower your dryer 7 Drying Rack This drying rack is designed specially for articles like sport shoes During drying please make sure the clothes reliably stay on the rack ...

Page 8: ...orrected with leveling legs located on the bottom of the dryer 1 remove all packaging material This includes the foam base and all adhensive tape holding the dryer acessories inside and outside 2 inspect and remove any remains of packing tape or printed material before using the dryer 7 Key points in installation adjustment and disassembly C C C C C Tools and materials required Electrical requirem...

Page 9: ...eptable 1 Only the rigid metal duct work should be used 2 Venting vertical through a roof may expose the exhaust system to down drafts causing an increase in vent restriction 3 Running the exhaust system through an uninsulated area may cause condensation and faster accumulation of lint 4 Compression or crimping of the exhaust system will cause an increase in vent restriction C C Location of your d...

Page 10: ...orrect Incorrect DO DON T Correct Incorrect Correct DO DON T Incorrect C C Requirements and instructions Electrical connections R E 1 This appliance MUST be properly grounded Electrical shock can result if the dryer is not properly grounded Follow the instructions in this manual for proper grounding 3 AU L approved strain relief must be installed onto power cord If the strain relief is not attache...

Page 11: ...ighten the tension relief nut securely so that the tension relief does not turn 9 Reinstall the terminal block cover Grounding instruction This appliances must be connected to a ground metal permanent wiring system or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead on the appliance nut tighten nut to these threads p...

Page 12: ...tence is not infinite Pull the power Yes Check and replace the power down lead Check and replace the computer program panel Check if the computer program panel is on Push down the searching unit and check if the door switch is on Check if the control thermostat and high limit thermostat are good Check if the heater is good Check if the motor is good Check if the wire unit is good while pushing dow...

Page 13: ...eater Check if the sequencer plug inserts correctly Check if the control thermostat and high limit thermostat act Replace the control thermostat and high limit thermostat Measure the resistance of the heater Replace the heater The heater is off The resistance is infinite Yes Check the ventilation condition Check if the vent pipe and the vent way is blocked No ventilating No No No Yes Yes Yes Check...

Page 14: ...r in the front of the cabinet and the cabinet or the abrasion between the support wheel and the bracket of support wheel Yes Yes Yes Yes No No No Fasten the support bracket or replace the support wheel Check the tensive condition replace the tensive spring Fasten the heating ring and the fasten screw Adjust or replace the worm shell If there is a noise from the tensive spring If there is metallic ...