![Haier Ginesis HLF103Q Service Manual Download Page 8](http://html.mh-extra.com/html/haier/ginesis-hlf103q/ginesis-hlf103q_service-manual_135845008.webp)
Power supply:
Power supply cord kit:
3 wire , 120 volt , 30 amp, 60Hz, 1 phase
(Not supplied when sold in the united states) the dryer MUST employ a 3-conductor power supply cord NEMA 10-30 type
SRDT rated at 120 Volt AC minium, 30 Amp, with 3 open end spade lug connectors with upturned ends or closed loop
connectors and marked for use with clothes dryer.
Use only 4 inch (10.2.cm) diameter (minimum) rigid or flexible
metal duct and approved vent hood which has a swing-out damper
hat open when the dryer is in operation . When the dryer stops, the
dampers automatically close to prevent drafts and the entrance of
insects and rodents . To avoid restricting the outlet, maintain a
minium of 12 inches ( 30.5 cm) clearance between the vent hood
and the ground or any other obstruction . The vent flap should be able to remove freely.
Select a suitable location for the dryer on a hard even surface away from direct sunlight or heat source
e.g. Radiators, baseboard heaters, cooking appliances etc . Any floor unevenness should be corrected
with leveling legs located on the bottom of the dryer.
1) remove all packaging material . This includes the foam base and all adhensive tape holding the dryer acessories
inside and outside.
2) inspect and remove any remains of packing, tape or printed material before using the dryer.
7
Key points in installation, adjustment and disassembly
C
C
C
C
C
T
ools and materials required
E
lectrical requirements
U
npacking your dryer
M
aterials
E
xhaust system connections
T
E
U
M
E
Measuring tape ( 12ft.min.)
Duct tape
Rigid or flexible metal 4 inch ( 10.2 cm) duct
Vent hood
Phillips head and flathead screwdrivers
Channel-lock adjustable pliers
1 2 inch open end wrench
Carpenter s level
CORRECT
INSTALL MALE FITTINGS IN CORRECT DIRECTION
INCORRECT
MAXIMUM LENGTH
of 4''(10.2cm)Dia.Rigid Metal Duct
VENT HOOD TYPE
(Preferred)
Louvered
Number
of
90
turns
0
1
2
3
4
60ft. (18.28 m)
48ft.(14.63 m)
52ft. (15.84 m)
40ft.(12.19 m)
44ft. (13.41 m)
32ft.(9.75 m)
32ft. (9.75 m)
24ft.(7.31 m)
28ft. (8.53 m)
21/2''
4''
(6.35 cm)
(10.2 cm)
16ft.(4.87 m)
MAXIMUM LENGTH
of 4''(10.2cm)Dia.Flexible Metal Duct
VENT HOOD TYPE
Louvered
(Preferred)
Number
of
90
turns
0
1
2
3
30ft. (9.14 m)
18ft.(5.49 m)
22ft. (6.71 m)
14ft.(4.27 m)
14ft. (4.27 m)
10ft.(3.05 m)
21/2''