– 49 –
Indoor Coil
Top Cover Panel
Left Side
Panel
2. Remove top cover panel and left-side panel.
3.
The filter drier capillary tube assembly is
located on the left-side of the Zoneline.
Service Filter Drier Capillary Tube Assembly
Indoor Coil Removal
1. Remove indoor fan assembly. See
Indoor
Fan Removal
under
Indoor Fan Motor
in the
Air Flow
section of this service guide.
Indoor Coil
Check Valve
Drier