– 36 –
6. Remove all harnesses from the left side going
through the harness guides towards the back.
Disconnect both thermistor connectors, both
fan motor connectors and reversing valve
connector form the main board. Then break
zip tie holding the indoor coil thermistor in
place and pull it out of its holder.
7. Lift indoor fan assembly straight up.
Harness
Guides
Zip Tie
Indoor Coil Thermistor
Thermistors
Reversing
Valve
Fan Motors
8. Set indoor fan assembly to the right of the
Zoneline. Notice the compressor is still
connected.
9. Remove fan shroud by removing a 13-mm
nut. The nut can be accessed with the heater
assembly installed, or remove the heater
assembly to gain easier access.
13-mm nut
(
Continued next page
)