REMOTE CONTROL FUNCTIONS
PAGE 18
ENGLISH
DIP Switch Settings
The PCB has a set of DIP switches that must be set when
replacing the PCB.
The replacement PCB is shipped with all switches set to the OFF
position.
Switch settings:
J5 Selects remote code A or B. Normally set to connection state
for code A operation. If two indoor units are used in the same area
and the user wishes to control them separately, switch J5 of the
second unit is set to the disconnected state for code B operation.
The wireless remote for the second unit is also set to code B.
J6 Selects room card able or disable. Normally set to connected
state. Set to the disconnected state when used in conjunction
with a room card interface utilized in hotel rooms.
SW-1 and SW-2 Selects EEPROM codes 23, 26, 33 and 35.
Set to identify the tonnage of the unit.
Settings:
1
ON
ON
OFF
OFF
2
ON
OFF
ON
OFF
35
33
26
23
DIP Switch
ON
OFF
J5
A
B
J6
N-RC
RC
J7
MAIN
SLAVE