ENGLISH
PAGE 6
INSTALLATION REQUIREMENTS
IMPORTANT:
e
v
r
e
s
b
O
all governing codes and ordinances. Check the location where the air
conditioner will be installed. Make sure you have everything necessary for correct
installation.
THE LOCATION SHOULD PROVIDE:
•
A
grounded electrical outlet within 6 ft. (183 cm) of where the power supply cord exits the air
conditioner, for models:
HWR05XCM ESA405N ESA406N ESA408N
•
A
grounded electrical outlet within 4 ft. (122 cm) of where the power supply cord exits the air
conditioner, for models:
ESA410N ESA412N
NOTE:
o
D not use an extension cord, plug adapter, surge protector or multi-outlet adapter.
• Free movement of air in the room to be cooled.
• A large enough window opening for the air conditioner.
(See Fig.2)
• T
installed in a double-hung window.
he air conditioner must not be installed in a through-the-wall sleeve or in a wall. It can only be
NOTE:
The outside cabinet louvers and air discharge must not be obstructed by bushes, trees, etc.
Air must be able to pass freely through the cabinet louvers.
(See Fig.1)
WINDOW INSTALLATION
Window opening measurements:
(See Fig.2)
LOCATION REQUIREMENTS
CABINET LOUVERS
Fig. 1
AIR DISCHARGE
HWR05XCM
ESA408N/ESA410N
ESA405N/ESA406N
A. Width Min/Max
22"-36"
24-1/2" - 36"
25" - 36-21/32"
26-1/8" - 37-25/32"
B. Height Min
13-3/8"
13-3/8"
14-9/16"
14-9/16"
ESA412N
A-WIDTH
B-HEIGHT
Fig. 2