background image

1

2

ES50V-G1(H)
ES70V-G1(H)

ES100V-G1(H)

Proprietary No.

**********

V

Please read this Instruction Manual carefully before use.

Please retain this manual for future reference.

Safety Notices 

(Please read before use)

Electrical Diagram

·

Exterior and accessories

·

Technical parameters

Electrical Diagram

Troubleshooting

Symptom

Things to Check

Solutions

No water

1

Whether the water supply has 

stopped or whether the water 

pressure is too low

Check

2

Whether the water-usage 

point is blocked or whether 

the hot water valve is opened

Check and clean

Only cold water but 

the heating indica-

tor lamp is lit

1

Whether hot water outlet is 

not opened

Check and open

2

Whether the water tempera-

ture is adjusted

Increase the temperature to the 

required value. Once the water is 

heated to the pre-set temperature, 

control 

 ow volume of cold and 

hot water using the moderating 

mixing valve.

3

Heating time is too short 

and set temperature is not 

achieved

Continue heating

4

Whetehr heating pipe is   

damaged

Con

 rm this is not due to the rea-

sons 

①②③

, then contact Mainte-

nance Department

Only cold water and 

the heating indica-

tor lamp is not lit

1

Whether power is properly 

connected

Check power socket

2

Whether thermostat is out of 

control

Con

 rm that this is not due to rea-

son 

, then contact Maintenance 

Department

Heating indicator 

light is on all the 

time

1

Water has not reached the set 

temperature

Continue heating

2

Whether thermostat is out of 

control

Con

 rm it is not due to reason 

then contact Maintenance Depart-

ment

Water volume is 

sometimes large or 

small, or water is 

sometimes hot or 

cold 

Whether water pressure             

is stable

Set lower mixing valve or ensure 

water pressure is stable before 

use

Small hot water 

out

 ow volume

1

Whether the present tempera-

ture setting is too low

Calibrate using the method stipu-

lated in the Instruction Manual

2

Whether water pressure is too 

much

Set lower mixing valve

Prohibited

Compulsory 

Matters

Essential 

Matters

Immediately cut off power supply and 

contact our Service Center once the 

water heater does not work properly 

or emits burnt smell.

This icon is used by Haier 

Water  Heaters  to  indicate 

"safety warning experts". It 

indicates  that  the  product 

is  equipped  with  special 

technology that constantly 

monitors the status of your earth line, 

to ensure safety during showering. If 

the icon is lit, it means that there is 

electricity in the earth line. You should 

immediately  stop  using  the  water 

heater and disconnect the power plug. 

Do not touch the outer casing of any 

electrical  appliances  in  your  home. 

Remember to also contact the local 

After-sales  department  or  property 

management  company  in  order  for 

them to engage quali

 ed electricians 

to carry out a system check until the 

icon is no longer lit.
The product is only available for 

To  ensure  safety,  the  water  heater 

should be connected to independent 

sockets (do not use adapters), with re-

liable earthing. In addition, the power 

socket must conform to national stan-

dards.  Use  of  water  heater  without 

reliable earthing is strictly prohibited. 

Use pen multimeter to check whether 

the live line and zero line are reverse.

Do not use damaged wire and power 

socket. Promptly clean the dust on the 

power plug and socket.

Check the power meter and the elec-

tric wire's diameter to ensure that they 

comply with the rated current for the 

water heater. Where necessary en-

gage quali

 ed electrician to check the 

electric circuit.

Do not touch the plug with wet hands, 

and make sure that the water heater, 

plug socket do not come into contact 

with water. If they are accidentally wet, 

they must be checked by professions 

appointed by our company before us-

ing, in order to prevent electrocution.

Storing of inflammable and explosive 

items near the water heater is strictly 

prohibited.

Do not connect to power when install-

ing or repairing the water heater.

Non-professionals are strictly prohib-

ited from carrying out repairs, m a i n -

tenance, dismantling or revamping of 

the water heater.

Installation of water heater outdoors is 

strictly prohibited.

Do not install the water heater in an 

environment which is susceptible to 

ice-formation. Ice will cause the con-

tainer and water pipe to break, lead-

ing to scalding and water leakage.

Please take precautionary measures 

during cold weather, in order to pre-

vent  damage  to  water  heater  from 

freezing.

If the soft power cable is damaged, 

it must be replaced by professional 

staff from the manufacturers or Main-

tenance Department in order to avoid 

danger.

Take care not to be scalded by heated 

water. 

·

Touching  of  hot  water  valve  and 

pipes is strictly prohibited.

·

Make sure to check the water tem-

perature before use; use only when 

it feels suitable.

Do not use water from the water heat-

er for drinking or similar purposes.

Please cut off the power supply if the 

water heater was not used for an ex-

tended period of time. Drain the water 

heater of all water according to the in-

structions in the chapter on Cleaning 

and Maintenance.

Forbidden

Warning

Caution

Caution

6767

w

e

i

v

 

n

o

it

c

e

s

-

s

s

o

r

C

w

e

i

v

 r

a

e

R

w

e

i

v

 t

n

o

r

F

Side view

A : Hot water outlet  B : Cold water inlet  C : Inner chamber   

D : Temperature measurement pipe           E : Heating pipe 

F : Magnesium rod  G : Wall hook

 

E

BT

MT

L

N

EH

E

HL

L  : Live wire (brown) 

N  : Zero line (blue)

MT : Manual-reset thermostat

BT : Adjustable thermostat 

HL : Heating indicator light 

EH : Heating pipe

E  : Earth line (yellow-green; 

        dual color)

Haier Home Water Heater

Instruction manual

Meanings of Icons

Earthing

Warning

Warning

Warning

Warning

Warning

Caution

Forbidden

Forbidden

Forbidden

Forbidden

Forbidden

Forbidden

Forbidden

CSH10D0037_en.indd   1

0040503115

V

Exterior and accessories

ES100V-R1(H)

Technical parameters

to high respectively.

Model No.

Capacity

(L)

Net 

weight(kg)

a1

(mm)

b1

(mm)

c1

(mm)

d1

(mm)

e1

(mm)

f1

(mm)

Note:

1.

 

The margin of error for the above parameters (measurements, weight) is ±10%.

 

2. The thermometer is not a precision instrument. It consists of three areas denoted by blue; 

orange and red, which indicate the temperature of water in the inner chamber from low 

ES50V-G1(H)

Unit

Ltem

ES70V-G1(H) ES100V-G1(H)

Water pressure

2150

0.80

0.80

2150

0.80

2150

ES100V-R1(H)

0.80

2000

MPa

ES50V-G1(H)
ES70V-G1(H)

ES100V-G1(H)

50

70

100

21

26
33

410
410

420
420

410

420

775

980

1300

100

200

220

100

200

480

100

200

730

100

33

410

420

1300

100

200

730

ES100V-R1(H)

alternating current.