-------Internal training document for Haier service provider. External disclosure is prohibited --- Classification
34
34
Low Temperature Alarm Solution:
14. explosive view
Freezer display temp.≤ set temp. for
low temp. alarm (set temp. for low
temp. alarm ≤ set temp. for running
-5
℃
)
Yes
No (normal)
Check the control circuit and LED lamps on the
display panel.
The “Alarm” indicator flickers; The
“Low-temp. Alarm” indicator
flickers;
Yes
The freezer makes an acoustic
alarm after the lamp flickers and
alarms for 15min.
No
Check the buzzer and control circuit on the control
panel.
Check if low & high temp.
compressors work properly.
Yes
No
Measure the actual temperature in
the freezer
Measure the actual temperature in the freezer
Summary of Contents for DW-86L486