20
• For any outage, the fully-charged controller could keep working for sending alarm
for 24h. For initial start of freezer or after a long time of outage, you should fi rstly
charge the battery fully, and keep the freezer under operation for continuous 12h.
• When the sensor fails, the system will enter into a self-protecting operation status,
the refrigerating system will automatically run for 8min by default, and then cease
for 9min, which will become a cycle operation until the fault is eliminated.
• For the function above mentioned, some differences might appear on different
models, so please subject to the machine you have bought.
Alarms
Symptom
Alarm indicator
the buzzer alarms
High
temperature
alarm
If the inner temperature sensed
by the sensor is higher than
-15
℃
or the setting high-
temperature alarm value,
The alarm light will fl ash and
"Hi" and inner temperature
will be alternately shown on
the temperature display area.
Alarm will be initiated
by impulsive sound
immediately
Low
temperature
alarm
If the inner temperature
sensed by the sensor is lower
than-35
℃
or the setting low-
temperature alarm value,
The alarm light will fl ash and
"Lo" and inner temperature
will be alternately shown on
the temperature display area.
Alarm will be initiated
by impulsive sound
immediately
Higher limit alarm
for temperature
If the temperature sensed by
the sensor is higher than 85
℃
The alarm light will fl ash and
"EHi" will be shown on the
temperature display area.
Impulsive sound
alarm
Lower limit alarm
for temperature
If the temperature sensed by
the sensor is lower than-50
℃
The alarm light will fl ash and
"ELo" will be shown on the
temperature display area.
Impulsive sound
alarm
Power failure
alarm
Power failure of the freezer
The inner temperature will be
shown for 0.5s and disappear
for 0.5s on the temperature
display area by turns for 24h
(when the battery is fully
charged)
Buzzer for 2 min
Sensor exception
Short circuit or open circuit of
temperature sensor
The alarm light will fl ash and
"Err" will be shown on the
temperature display area.
Impulsive sound
alarm
DW-30L278FL/278SF
9
Leveling leg
5. Install the brackets(DW-30L278FL/SF)
Remove bolts from the back of cabinet, and then fi x the back
bracket for rear wall distance with the removed bolts.
1.Taking of the packaging materials and the packing tape
Take off all packing materials and packaging tapes for transportation.
2.Ckeck of accompanying accessories
Please check the box contents as per the packing list. If there is any mistake, please contact the
aftersales department timely.
3.Storage condition
At least a 10cm gap shall be left around the storage box, to ensure the
well air ventilation and to facilitate the heat radiation.
4. Adjustment of leveling leg
Please use a wrench to turn the horizontal leveling leg clockwise so that
the horizontal leveling leg are extended outwards and suppoted on the
ground. Make sure that the freezer is not movable in time of use.
Keep the plastic bag away from the children.
Suffi cient sapce shall be kept at the engine-room grilling,
to facilitate maintenance and ventilation.
Summary of Contents for DW-25L92FL