background image

 Part number 20073, Rev 0 

 

 

 

 
 
 

 

 
 
 
 
 
 
 
 
 
 

UNDERCOUNTER BUILT IN PLUS SERIES FREEZERS 

SCUCBI-0420, SCUCBI-0420SS, SCUCBI-0420AD 

OWNER’S INSTRUCTIONS 

This manual describes how to operate and care for your appliance to get the best, most efficient, performance. 

READ THIS BOOK! 

Note to Customer: 

This  merchandise  was carefully packed and thoroughly inspected  before leaving our plant.  Responsibility for its 
safe  delivery  was  assumed  by  the  carrier  upon  acceptance  of  the  shipment.    As  directed  on  the  side  of  your 
packing carton, claims for loss or damage sustained in transit must be made on the carrier as follows: 
 
A.)

 

Visible Loss, Damage, Shortage External Evidence of Loss or Damage: 

This type of damage 

must

 be noted on 

the freight bill and acknowledged by the carrier’s agent (driver) at time of delivery. Make sure you get a signed 
copy. Send a written request for an inspection to the carrier.  

B.)

 

Concealed  Damage

:  This  type  of  damage  may  not  be  discovered  until  the  unit  is  being  unpacked.  When 

concealed  damage is discovered, stop unpacking immediately  and contact the carrier immediately to report 
the claim and request an inspection. This should be done as soon as possible and, in any case, must be done 
within 15 days or receiving the merchandise. If at all possible, do not  move the item and save all packaging 
material for carrier’s inspection.  

C.)

 

FAILURE  TO  FOLLOW  THESE  INSTRUCTIONS  MAY  RESULT  IN  THE  CARRIER  REFUSING  TO  HONOR  YOUR 
COMPANY’S  CLAIM.  UNDER  NO  CIRCUMSTANCES  SHOULD  THE  MERCHANDISE  BE  RETURNED  TO  THE 
MANUFACTURER. NO RETURNS WILL BE ACCEPTED WITHOUT PRIOR AUTHORIZATION. 

 
 

 

Horizon Scientific 

125 Varnfield Drive 
Summerville, SC 29483 
Phone:  800-648-4041 
Fax:      843-821-8051 

Warranty: 

Two-Year Parts and Labor 
5 Years Compressor Parts 

Revision Date 

08/23/2012 

 

 

 

 

 

Summary of Contents for SCUCBI-0420

Page 1: ...f delivery Make sure you get a signed copy Send a written request for an inspection to the carrier B Concealed Damage This type of damage may not be discovered until the unit is being unpacked When concealed damage is discovered stop unpacking immediately and contact the carrier immediately to report the claim and request an inspection This should be done as soon as possible and in any case must b...

Page 2: ... SERVICE please have the unit s model and serial number ready as well as the problem description The model and serial number is located on the serial tag which can be found on the interior left OR right upper wall of the unit For convenience you may want to record the following information here for easy access in the future Model number __________________________________ Serial number ____________...

Page 3: ...ry receipt acknowledging the damage This has to happen at the time of delivery or it won t happen at all Keep a copy for your records and send another to the carrier s damage claims department along with a formal request for an inspection report Follow up with a phone call Their contact information can be found on the carrier s web site The second type of shipping damage is concealed damage This t...

Page 4: ...his cabinet must conform to all National and Local Electrical Codes Consult the cabinet Serial Data plate for voltage cycle phase and amp requirements before making connection VOLTAGE SHOULD NOT VARY MORE THAN 5 FROM SERIAL PLATE RATINGS A separate circuit is recommended to prevent possible loss of product due to over loading or failure of other equipment on the same circuit PROTECT THE CIRCUIT WI...

Page 5: ...pecially if the weather is very hot This is normal The motor compressor will cycle normally as soon as the excess heat has been removed TEMPERATURE CONTROL NOTE The control is preset at the factory to provide the desired air and product temperatures inside of the unit and requires no further adjustment Please contact the manufacturer s Technical Service Department before making any adjustments to ...

Page 6: ...anged through the bottom front grill Please ensure the bottom front grill is free from dust or any object that may block the airflow When loading the top shelf avoid blocking the evaporator fan s if installed There should be at least 4 inches of clearance around the fan to allow proper air flow Do not overload the unit Maximum suggested load is about 75 of the chamber volume Additionally the load ...

Page 7: ...vides the following functions Red LED for visual indication of an alarm condition Beeper for audible indication of an alarm condition A preprogrammed 5 minute delay from the time a set point is attained until an alarm condition is declared This prevents spurious alarms for things like door openings Operating Mode The Electronic Temperature Control normally displays the current interior temperature...

Page 8: ...w Pon The control keys are now unlocked and you can perform the programming functions below Adjusting the temperature control set points NOTE The temperature control set points are preset at the factory to provide the desired air and product temperatures inside of the unit and require no further adjustment Please contact the manufacturer s Technical Service Department before making any adjustments...

Page 9: ...display Press the UP or DOWN keys several times to cycle through the parameters until CF is displayed Press SET to display the current setting either C for Celsius or F for Fahrenheit Use the UP or DOWN key to choose the desired setting Press SET again to lock it in Press SET and UP to return to Operating Mode To change the Hi or Low Alarm set points press SET and DOWN keys for 3 seconds to enter ...

Page 10: ...ed the proper refrigerator air circulation For the proper air circulation place the products evenly on each shelf Do not push against the refrigerator s rear or side walls Evaporator is blocked by frost or ice Remove the products unplug the refrigerator or freezer power and allow the unit to defrost If the problem still exists call for service Appliance runs too long Prolong door openings Control ...

Page 11: ...above 40C 104F Stop using immediately The display shows LL and the compressor does not run The ambient temperature is below 40C 40F Stop using immediately MOISTURE DURING THE SUMMER SEASON The amount of moisture condensation or high humidity related issues increase during the summer and in most cases will self resolve when the weather cools down Please note a refrigeration system does NOT generate...

Page 12: ... not use commercial household cleaners ammonia or alcohol to clean handles Use a soft cloth to clean smooth handles Do not use a dry cloth to clean smooth handles STAINLESS STEEL CARE AND CLEANING Use the proper tools When cleaning stainless steel surfaces take care to use non abrasive tools Soft cloths and plastic scouring pads will not harm the steel s passive layer Stainless steel pads may be u...

Page 13: ...t removal on all finishes Grease oil Any good commercial detergent Apply with a sponge or cloth Restoration Passivation Benefit Super Sheen Passive Film Breakdown Corrosion on metals is everywhere We recognize it quickly on iron and steel as unsightly yellow orange rust Such metals are called active because they actively corrode in the natural environment Contrary to popular belief Stainless Steel...

Page 14: ...gging to avoid electrical hazard DO NOT ADJUST THE TEMPERATURE CONTROL Remove the product and leave the door open while defrosting the freezer Place towels in the bottom of the freezer to catch the frost When all frost has fallen remove the towels Defrosting tips If the frost is soft remove it with a plastic scraper If the frost is glazed and hard fill deep pans with hot water and place them insid...

Page 15: ...be paid by the customer ADDITIONAL THREE YEAR COMPRESSOR WARRANTY In addition to the two 2 year warranty stated above Horizon Scientific Inc warrants its hermetically and semi hermetically sealed compressors to be free from defects in both material and workmanship under normal use and service for a period of three 3 additional years from the end of the initial two 2 year warranty period but not to...

Page 16: ...nt damage during transit or installation fire flood or other external causes It does not apply to defects resulting from failure to properly install operate or maintain the product in accordance with the printed instructions provided or damage caused by the storage of any corrosive material that comes in contact with the interior or exterior portions of the cabinet or the use of spark producing eq...

Reviews: