background image

Installation precautions

This description does not address to all possible cases. For new requirement and query, please
consult the regional sales center of Haier Air Conditioner General Co., Ltd.

This instruction manual must be read carefully before beginning of installation, improper ins-
tallation may cause accidents and thus bring about machine damage and personal casualty.

Installing tools

1. Screw driver                               6. Pipe cutter         10. Leakage detector or soap water

2. Hacksaw                                     7. Pipe expander    11. Measuring tape

3. Driller of 70mm diameter           8. Knife                 12. Scraper

4. Spanner (diameter 17, 27mm)    9. Pinchers             13. Refrigeration oil

        5. Spanner (14, 17, 19, 27mm)

18

!  Attention

!   Warning

Summary of Contents for AE182FCAHA

Page 1: ...AE092FCAHA AE182FCAHA 0010570925 A Household MRV Ceiling Concealed Type Room Air Conditioner...

Page 2: ...1...

Page 3: ...2...

Page 4: ...3 AE092FCAHA AE182FCAHA...

Page 5: ...T FAN For setting a desired temper ature value Power ON OFF key CLOCK key TIMER key SET key HOUR step key SLEEP key For checking the clock time For selecting timer mode TIMER ON TIMER OFF TIMER ON OFF...

Page 6: ...manual to new user if you resell this machine Warning Warning for installation l Entrusted Installation Installation of the machine should be entrusted to certified person of after service Unauthoriz...

Page 7: ...ervice Improper inst allation may cause fire hazard electric shock or damage of ma chine l Unauthorized alteration or repair work is strictly forbidden Impr oper alteration or maintenance may cause fi...

Page 8: ...NNOT be used for the purpose of prese rving food animals plants precision instruments and artwork etc which may be destroyed otherwise DON T replace fuse with ma terial other than fuse of proper capac...

Page 9: ...d i s p l a yw i l ls t o pa t A U T O o r F A N L O W M I D H I G H A U T O Fan speed adjustment Pressthe F ANSPEED keytochangethefanspeed Every p r e s s i n gw i l lc h a n g et h ef a ns p e e di...

Page 10: ...Every time pressing the key the temperature setting will decrease by 1o C Set a suitable temperature value Fan speed selection P r e s st h eF A N S P E E D k e yt oc h a n g et h ef a ns p e e d E a...

Page 11: ...w flashes 3 Set time Press TIMER SETTING step keys Every time pressing the key will increment the time setting by 10 min while kept pressing will increase quickly Every time pressing the key will decr...

Page 12: ...isplays the time setting which could be freely adjusted within 24 hours 4 Time confirming for TIMER ON After time setting press the SET key to confirm the time TIMER ON doesnt flash any longer while T...

Page 13: ...our after SLEEP mode starts temp will become 2 lower than temp setting After another 1 hour temp decreases by 1 further This temperature will be maintained for 3 hours before rising by 1 The unit will...

Page 14: ...on or cold shrinkage of plastics Sometimes there are smells in the air flow from the indoor unit This is caused by the smell of cigarettes or paint coatings inside the unit During COOL or DRY operatio...

Page 15: ...nue to run for a while to eliminate residual heat Before asking for after service to an authorized service center please check your air conditioner for the following items The system couldnt start Is...

Page 16: ...re any direct sunlight into the room Are there too many people in the room If after the above checks and the corresponding corrective actions the system remains abnormal operation or the following fac...

Page 17: ...and outdoor unit shall be 30 m l Please keep the installation instruction manual well for reference in maintenance or changing installation position After installed please follow the operational instr...

Page 18: ...accidents will happen Using the specified cable to do wiring work and connecting firmly and properly Fix the connecting part of the terminals to prevent it from the external force Improper connection...

Page 19: ...read carefully before beginning of installation improper ins tallation may cause accidents and thus bring about machine damage and personal casualty Installing tools 1 Screw driver 6 Pipe cutter 10 L...

Page 20: ...cian so as to avoid risks l Power cord plug L should be connected to the live wire N should be connected to the neutral wire and to the ground wire l Connection wire size 3 x 1 25 1 5 mm2 type of YZW...

Page 21: ...ndow in contact with high humidity external air Easy to generate dew l Locations frequently using special aerosols Indoor unit 1 Select suitable places the outlet air can be sent to the entire room an...

Page 22: ...rd down slope of at least 1 100 See Figure 2 2 Before drilling check that there is no pipe or reinforcing bar just behind the drilling position Drilling shall avoid at positions with electric wire or...

Page 23: ...not exceed 0 5 m 22 A 0 5m Installing building roof Ceiling Air supply Air outlet duct Unit Return air Return air bellows Figure 3 Detail A Figure 5 M8 broad foundation bolt M8 suspension screw M8 bro...

Page 24: ...pension screws Square wood Suspension screw Beam New concrete slab To set with embedded parts foundation bolts etc Iron reinforcement Knife embedded part Foundation bolt Guide plate embedded part Pipe...

Page 25: ...oles in the back cover of the remote controller subseque ntly plug a cork into each wall hole Align the 3 screw holes in the back cover of the remote controller with the corks and then fasten the back...

Page 26: ...care not to apply external force onto the drain pipe connection part Pipe and insulation material Rigid PVC pipe VP31 5mm internal diameter Foamed PE with thickness above 10mm Pipe Insulation Hose Dr...

Page 27: ...ant shall be R407C The adding procedure shall be aided with a measuring meter for a specified amount of supplemented refrigerant Requirement l Overfilling or underfilling of refrigerant will cause com...

Page 28: ...at if there is gas leakage at the pipe connections and bonnets Insulation treatment Conduct insulation treatment on both the gas side and liquid side of pipes respectively During cooling operation bot...

Page 29: ...ent leakage breaker shall be installed otherwise it electric shock would happen easily l If the power cord is damaged it must be replaced by the manufacturer or its service center or similar personnel...

Page 30: ...m outside the connection wire and signal transmission wire through the wall hole with pipeline already arranged l Pull out the front ends of connection wire and signal wire and make a circle on the si...

Page 31: ...e settings There is a 4 position dial switch for setting the indoor unit number on the computer board of the indoor unit Setting way is as follows Before connecting the power supply please set the ind...

Page 32: ...es E9 you may check the indoor unit main board LED1 or outdoor unit main board LED1 AU242FHAHA outdoor unit main board LED ALARMA or ALARMB AU422FIA HA AU422FIAIA Trouble description Outdoor unit defr...

Page 33: ...oor outdoor Is there any gas leakage at the pipe joints connection wire connected properly Are the wires pressed firmly Is the noise too big Do the terminal numbers of the indoor outdoor connection wi...

Reviews: