please check the following things about your air conditioner before making a servie call.

Unit fails to start

ON

OFF

Is the power source
switch adjust cut in?

Is city supply power in
normal?

Power
stoppage?

Isn't the signal receiving
section exposed to the
direct sunlight or strong
illumination?

Isn't the earth leakage
breaker in action?

It is dangerous. Turn off
the power supply switch
immediately and contact
the sales dealer.

Power supply switch is
not ON.

Cooling or heating is not sufficient

Is the thermostat adjust
as required?

Isn't the air filter dirty?

Isn't any doors or windows
left open?

Doesn't any obstacle
exist at the air inlet or
outlet?

Cooling  is not sufficient

Isn't sun-shine invading
direct?

Isn't any unexpected
heating load generated?

Isn't the room much
crowded?

Isn't the swing louver
horizontal?
(At HEATING mode)

If swing louver is horizontal,
the blow wind does not reach
floor.

The wind does not blow
during heating operation

Isn't it warming up?

When the air conditioner does not operate properly after you have checked the above mentioned
items or when the following phenomenon is observed, stop the operation of the air conditioner
and contact your sales dealer.

The fuse or breaker often shuts down.
Water drops off during cooling operation.
There is a irregularity in operation or abnormal sound is audible.
When the CHECK LED (red) flickers of wired controller, an irregularity has occurred in the
air conditioner.

Malfunction

7

Summary of Contents for AD182AMBEA

Page 1: ...DITIONER AD182AMEAA AD242AMEAA AD282AMEAA AD362AMEAA AD422AMEAA AD482AMEAA AD522AMEAA AD182AMERA AD242AMERA AD282AMERA AD362AMERA AD422AMERA AD522AMERA Please read this operation manual before using the air conditioner Please keep this manual carefully and safely ...

Page 2: ...unction 7 8 Care and Maintenance 9 For Preparation of Heating Hot Keep 10 Is The Unit Installed Correctly 11 Installation Manual For Indoor Unit 12 18 Safety Precautions 3 5 Parts and Functions 6 Cautions 2 Trouble Shooting 19 ...

Page 3: ... an appropriate anti pollution method of disposal Disposal of the packaging of your new air conditioner All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service The wrapping bag made of polyethylene and the polyethylene ...

Page 4: ...cident by some improper handing Do not install nearby the place where may have leakage of flammable gas Depending on the place of installation a circuit breaker may be necessary Drain pipe should be arranged to provide a positive draining If the gas leakes and gathers around it may cause the fire Unless the circuit breaker is installed it could cause elecrical shocks Where strong winds may prevail...

Page 5: ...m is operated at the vicinity of such equip ment which generates steam condensed water may drip during cooling operation or it could cause a fault current or short circuit When operating the system simultaneously with a combustion apparatus indoor air must be ventilated frequently Check occasionally the support structure of the unit for any damage after a use of long period of time Insufficient ve...

Page 6: ...should be H05RN F 4G 0 75mm2 All the cables shall have got the European authentication certificate During installation when the connecting cables break off it must be assured that the grouding wire is the last one to be broken off 6 The power cable and connect cable should be self provided 7 The breaker of the air conditioner should be all pole switch and the distance between its two contacts shou...

Page 7: ...Parts and Functions 6 Air outlet Air inlet Duct Air outlet Air inlet Duct For series 182 242 282 For series 362 422 482 522 ...

Page 8: ... at the air inlet or outlet Cooling is not sufficient Isn t sun shine invading direct Isn t any unexpected heating load generated Isn t the room much crowded Isn t the swing louver horizontal At HEATING mode If swing louver is horizontal the blow wind does not reach floor The wind does not blow during heating operation Isn t it warming up When the air conditioner does not operate properly after yo...

Page 9: ...he FAN mode during cooling To prevent frost from being accumulated on the indoor unit heat exchanger it is sometimes automatically switched to the FAN mode but it will soon return to the cooling mode Even if the operation switch is turned on cooling dehumidifying or heating is not operable for three minutes after the conditioner is stopped Because the protecting circuit is activated During this ti...

Page 10: ... no obstacles blocking the air inlet and air outlet of both indoor and outdoor units Make sure that the air filter is not dirty Cut in the power supply switch 12 hours before starting run Post Season Care Operate the unit with FAN mode on a fair day for about half a day to dry the inside of the unit well Stop operation and turn off the power supply switch Electric power is consumed even the air co...

Page 11: ...over to ordinary heating operation WARMING OPERATION Heat pump type warming Defrosting operation Atmospheric temperature and warming capacity Period of warm up With the heat pump type warming the mechanism of heat pump that concentrate heat of outdoor air with the help of refrigerant to warm the indoor space is utilized When a room is warmed with a heat pump type air conditioner frost accumulates ...

Page 12: ...gas generates Hot spring area etc The place where salt breeze blows Seaside etc The place where dense soot smoke exists The place where humidity is extraordina rily high The place where near the machine which radiates the electromagnetic wave The place where voltage variation is con siderably large For details consult your sales dealer The electric work must be burden on the authorized engineer wi...

Page 13: ...When strength is insufficient injury can result from a falling of the unit Execute the prescribed installation construction to prepare for earthquakes and the strong winds of typhoons and hurricanes etc Improper installations can result in accidents due to a violent falling over of the unit For electrical work please see that a licensed electrician executes the work while following the safety stan...

Page 14: ...t of your client user a Places where chilled or heated air circulates freely When the installation height exceeds 3m warmed air stays close to the ceiling In such cases suggest your client users to install air circulators b Places where perfect drainage can be prepared and sufficient drainage c Places free from air disturbances to the suction port and blowout hole of the indoor unit places where t...

Page 15: ...tallation Manual For Indoor Unit For series 362 422 482 522 For series 182 242 282 3 Avoid installation and use at those places listed below a Places exposed to oil splashes or steam e g kitchens and machine plants Installation and use at such places incur deteriorations in the performance or corrosion with the heat exchanger or damage in molded synthetic resin parts b Places where corrosive gas s...

Page 16: ... drain pipe to unit pay suffcient attention not to apply excess force to the piping on the unit side Also fix the piping at a point as close as possible to the unit For drain pipe use hard PVC general purpose pipe VP 25 I D 1 which can be purchased locally When connecting insert a PVC pipe end securely into the drain socket before tightening securely using the attached drain hose and clamp Adhesiv...

Page 17: ...h for the needed height is higher than 500 mm the back flow quantity of drain at the event of interruption of the operation gets too much and it may cause overflow at the drain pan Therefore make the height of the drain pipe within the distance given in the sketch below Avoid positioning the drain piping outlet at a place where generation of odor may be stimulated Do not lead the drain piping dire...

Page 18: ... duct flange Conduct the duct installation work before finishing the ceiling 8 Connection of suction exhaust ducts a Duct connection position i Fresh air inlet Inlet can be selected from the side or rear faces depending on the working conditions Use the rear fresh air inlet when the simultaneous intake and exhaust is conducted Side inlet cannot be used ii Exhaust Make sure to use also the suction ...

Page 19: ...unit so that the power for the outdoor unit is supplied by terminals Item Model Phase Switch breaker A Circuit breaker Overcurrent protector rated capacity A Power source wire size minimum mm2 30 20 2 5 Switch breaker A Earth leakage breaker Leak current mA 30 Installation Manual For Indoor Unit 30 1 40 26 2 5 40 For series 242 282 3 L N 1 2 3 Y G INDOOR UNIT TERMINAL BLOCK POWER 1PH 220 230V 50Hz...

Page 20: ...usly Sensor broken down or short circuit for more than 2m continuously Sensor broken down or short circuit for more than 2m continuously CT check abnormal 3 times in 30m High pressure switch acts 3 times in 30m Fault phase short of phase out of balance greatly Communication abnormal for more than 4m continuously Communication abnormal for more than 4m continuously Float switch broken down for more...

Page 21: ...HAIER GROUP Qingdao Haier Air Conditioner Electric Co Ltd Address Haier Garden Qianwangang Road Economic Development Zone Qingdao Shandong 266500 P R China Web Site http www haier com ...

Reviews: