background image

1

.  

SELECTING THE MOUNTING POSITION

(1) Decide the mounting position with the customer as follows:

NOTE: The appearance may be different from models.

For authorized service personnel only

WARNING

WARNING

CAUTION

Note: For series 36,42 no floor console type, the function below about floor console is invalid to
          the series.

Installation of Indoor Unit

12

Be careful not to scratch the room air conditioner when handing it.
After installation, explain correct operation to the customer, according to the operating manual.
Let the customer keep this installation manual because it will be used when the room air conditioner
is serviced or moved.

(1) For the room air conditioner to operate satisfactorily, install it as outlined in this installation
      manual.
(2) Connect the indoor unit and outdoor unit with the room air conditioner piping and cords available
      from our standard parts. This in stallation manual describes for the correct connections so that the
      installation set available from our standard parts should be used.
(3) Installation work must be performed in accordance with national wiring standards by authorized
      personnel only.

(4) Never cut the power cord, lengthen or shorten the cord, or change the plug.

(5) Also, do not use an extension cord.
(6) Plug in the power cord plug firmly. If the receptacle is loose, repair it before using the room air
      conditioner.
(7) Do not turn on the power until all installation work is done.

Install the indoor unit level on a strong wall, floor, ceiling which is not subject to vibration.
The inlet and outlet ports should not be obstructed: the air should be able to blow all over the room.
Install the unit near an electric outlet or special branch circuit.
Do not install the unit where it will be exposed to direct sunlight.
Install the unit where connection to the outdoor unit is easy.
Install the unit where the drain pipe can be easily installed.

Do not install where there is the danger of combustible gas leakage.
Do not install near heat sources.
If children under 10 years old may approach the unit, take preventive measures so that they
cannot reach the unit.

Install at a place that can withstand the weight of the indoor units and install positively so that
the units will not topple or fall.

Summary of Contents for AC092ACBHA

Page 1: ...HCFU 12HA03 R1 B No 0010572437 A CLIMATISEUR CONVERTIBLE APPARENT MONTAGE AU SOL PLAFONNIER Manuel d utilisation Veuillez lire attentivement ce manuel d utilisation avant d utiliser le climatiseur Ve...

Page 2: ...1 2 Pr cautions de s curit 3 Caract ristiques et Fonctions 4 Nomenclature des pi ces 5 Nettoyage et entretien 6 R solution des probl mes 7 8 Conseils pour un bon fonctionnement 9 Installation de l app...

Page 3: ...our l environnement L emballage carton peut tre d chir ou d coup en petits morceaux puis donn un service de recyclage du papier Le sac ayant servi l emballage est compos de poly thyl ne et les amortis...

Page 4: ...t des tubes quels qu ils soient ou encore en grattant les rev tements de surface Si la mati re r frig rante est ject e du tube directement dans les yeux elle peut provoquer de graves l sions oculaires...

Page 5: ...reil pendant de longues p riodes mettez hors tension la source d alimentation lectrique V rifiez l tat de l installation et l absence de dommages Ne placez pas d animaux ni de plantes sur la trajectoi...

Page 6: ...e coupe automatiquement MODE CHAUD HEATING FROID COOLING Si vous pressez le bouton SLEEP SOMMEIL au cours du mode chaud HEATING le r glage du thermostat du climatiseur baisse petit petit pendant le fo...

Page 7: ...nuterie TIMER 7 Indicateur de fonctionnement du compresseur 8 Grille d admission Fig 3 9 Filtre air 10 d flecteurs air haut bas UP DOWN 11 Volets de ventilation droite gauche RIGHT LEFT situ s derri r...

Page 8: ...sur les filtres air en aspirant ou lavant ces derniers Apr s lavage laisser s cher compl tement les filtres air dans une zone prot g e du soleil 1 2 3 Les filtres se logent sur le c t de la grille d...

Page 9: ......

Page 10: ...de l appareil du fait des changements de temp ratures Cela provient du fait que le syst me brasse les odeurs d sagr ables qui se trouvent l int rieur de la pi ce telles que l odeur de cigarette ou de...

Page 11: ...ent de l eau s chappe de l appareil en mode froid COOLING ou d shumidification DRY ou le fonctionnement est anormal ou l on entend des sons anormaux R solution des probl mes Description de la panne Fo...

Page 12: ...ra bri vement pendant environ 7 15 minutes Au cours de l op ration de d givrage automatique la DEL OPERATION EN FONCTIONNEMENT clignotera D faut d efficacit alarmant Si un probl me quel qu il soit sur...

Page 13: ...high salt content in the air c Near to hot spring with high content of sulfide gases d Area with frequent fluctuation of voltage e g factory etc e In vehicles or ships f Kitchen with heavy oil vapour...

Page 14: ...3 Installation work must be performed in accordance with national wiring standards by authorized personnel only 4 Never cut the power cord lengthen or shorten the cord or change the plug 5 Also do no...

Page 15: ...nit on the wall For series 28 36 42 no this part Name and shape Q ty Application 6 For fixing the wall bracket For series 28 36 42 no this part Tapping screw 4x20 Coupler heat insulator large 1 For in...

Page 16: ...28 36 42 have not the power plug A FLOOR CONSOLE TYPE For series 36 42 no this type 1 DRILLING FOR PIPING Select piping and drain directions Fig 2 Series14 18 24 The piping and drain can be made in t...

Page 17: ...ht A should be less than 5 mm Fig 9 Fig 9 Fig 5 Wrap the insulation drain hose around the drain hose connection Fig 7 Fig 7 Wall 10cm 6mm Indoor unit outdoor unit Fig 4 For series 14 18 24 when instal...

Page 18: ...elected drill 80mm and 50mm or 150mm dia hole on the wall so that the hole is tilted downward toward the outdoor for smooth water flow With a concrete drill drill four 12 7 mm dia Holes Fig 12 A B 40...

Page 19: ...th sides Fig 16 Bolt Bracket Indoor unit 5 INSTALL THE DRAIN HOSE Select whether the drain hose will be connected to the left or right side Fig 3 Insert the drain hose into the drain pan then secure t...

Page 20: ...INSPECTION After connecting the piping check the joints for gas leakage with gas leakage detector HOW TO CONNECT WIRING TO THE TERMINALS A For solid core wiring or F cable Fig 19A 1 Cut the wire with...

Page 21: ...eplace and tighten the terminal screw using a screw driver 19 After passing the connection cord and power cable through the insulation tube fasten it with the cord clamp as shown in Fig 20 HOW TO FIXE...

Page 22: ...mly to the terminal block Imperfect installation may cause a fire 3 Always fasten the outside covering of the connection cord with the cord clamp If the insulator is chafed electric leakage may occur...

Page 23: ...ve the four tapping screws CAUTION Do not remove the screws If the screws are removed the electric component box will fall Electric component box Base Electric component box cover Remove the three tap...

Page 24: ...s use a circuit that can trip all the poles of the wiring and has an isolation distance of at least 3mm between the contacts of each pole 4 Perform wiring work in accordance with standards so that the...

Page 25: ...and the air conditioner is difficult to start contact the power company the voltage raised CAUTION CUSTOMER GUIDANCE Explain the following to the customer in accordance with the operating manual 1 St...

Page 26: ......

Reviews: