.10 The communication fault between indoor and outdoor
Indoor display E7
outdoor display LED1 flash 15 times
Communication is detected by checking the indoor PCB and the outdoor PCB.
■
The outdoor PCB broken leads to communication fault.
■
The indoor PCB broken leads to communication fault.
■
Communication wiring disconnected.
■
The indoor PCB is broken.
■
The outdoor PCB is broken.
■
The Module PCB is broken.
* Caution
Be sure to turn off power switch before connect or disconnect connector, or else
parts damage may be occurred.
NO
˄
A
˅
Yes
NO
Yes
No
YES
Restart the a/c and it
becomes normally.
If starting up normally, but
malfunction occurs again after a
while
Check whether the linking cable
between the indoor and outdoor is well
connected or whether its core wires are
well insulated.
The outdoor mainboard needs
dehumidification.
The outdoor mainboard needs
dedust.
1. Reconnect the linking cable;
2. Replace the linking cable with new
one.
Service diagnosis
Domestic air conditioner
Conditions
Supposed
Causes
Troubleshooting
Method of
malfunction detection
Malfunction detection
conditions
Summary of Contents for 2U14CS4ERA
Page 10: ... Pinping diagrams Domestic air conditioner 4ˊPinping diagrams 8 ...
Page 11: ... Operation range Domestic air conditioner 5ˊOperation range 9 ...
Page 15: ...PCB 2 CN1 CN5 CN6 CN7 CN10 CN11 CN8 CN9 CN2 CN3 CN4 Domestic air conditioner Wiring diagram ...
Page 16: ...0 Wiring diagram Domestic air conditioner ...
Page 35: ...WARNING CAUTION Installations Domestic air conditioner 33 ...
Page 36: ...Installations Domestic air conditioner 34 ...
Page 37: ...Installations Domestic air conditioner 35 ...
Page 38: ...Installations Domestic air conditioner 36 ...
Page 39: ...Installations Domestic air conditioner 37 ...
Page 40: ...Installations Domestic air conditioner 38 ...
Page 41: ...Installations Domestic air conditioner 39 ...
Page 85: ...1 Removal Procedure 1 Domestic Air Conditioner p ...
Page 87: ...Loosen the screws and pull the panel Removal Procedure 3 Domestic Air Conditioner ...
Page 89: ...Removal Procedure 5 Domestic Air Conditioner 2 ...
Page 90: ...Removal Procedure 6 Domestic Air Conditioner 3 ...
Page 91: ...2 Loosen the fixing screws and remove the motor Removal Procedure 7 Domestic Air Conditioner ...
Page 92: ...Removal Procedure 8 Domestic Air Conditioner 4 F M P B ...
Page 93: ...and remove the reactor Loosen the screw Removal Procedure 9 Domestic Air Conditioner ...