Service diagnosis
Domestic air conditioner
10.2 Problem Symptoms and Measures
e
r
u
s
a
e
M
f
o
s
li
a
t
e
D
m
e
tI
k
c
e
h
C
m
o
t
p
m
y
S
None of the units
operates
Check the power supply.
Check to make sure that the rated voltage is supplied.
Check the indoor PCB
Check to make sure that the indoor PCB is broken
Operation
sometimes stops.
Check the power supply.
A power failure of 2 to 10 cycles can stop air conditioner
operation.
Equipment
operates but
does not cool, or
does not heat
(only for heat
pump)
Check for faulty operation
of the electronic
expansion valve.
Set the units to cooling operation, and compare the
temperatures of the liquid side connection pipes of the
connection section among rooms to check the opening and
closing operation of the electronic expansion valves of the
individual units.
Diagnosis by service port
pressure and operating
current.
Check for insufficient gas.
Large operating
noise and
vibrations
Check the installation
condition.
Check to make sure that the required spaces for
installation (specified in the Technical Guide, etc.) are
provided.
31
Summary of Contents for 1U18TR4ERA
Page 11: ...Pinping diagrams Domestic air conditioner 4 Piping diagrams 9 EEV EEV ...
Page 12: ...Operation range Domestic air conditioner 5 Operation range 10 ...
Page 63: ...Domestic air conditioner Removal of procedure 1 Removal of Outdoor panel 1 ...
Page 65: ...Domestic air conditioner Loosen the screws and pull the panel Removal of procedure 3 ...
Page 66: ...Domestic air conditioner 2 Removal of Electrical Box Removal of procedure 4 ...
Page 67: ...Domestic air conditioner 3 Removal of Fan and Fan Motor Removal of procedure 5 ...
Page 69: ...Domestic air conditioner 4 Removal of Fan Motor Bracket and Partition Removal of procedure 7 ...
Page 70: ...Domestic air conditioner and remove the reactor Loosen the screw Removal of procedure 8 ...