INSTALLATION

PAGE 3

ENGLISH

2.1

 

Step 2.1

 

Using a stud sensor, locate and mark the stud positions in the 
wall where the indoor unit is to be mounted. 

2.2

 

Step 2.2

 

Place the mounting plate on the wall in the desired location 
taking into account the minimum clearances necessary for 
proper operation.

Using a level, verify the mounting plate is horizontal and mark 
the screw locations.

2.3

 

Step 2.3

 

Screw the mounting plate to the wall.

The piping for the indoor unit may be routed to the unit from 
one of several directions. Left, Left Rear, Right, Right Rear, or 
Below (Illustration 1).

2.4

 

Step 2.4

 

Knockouts are provided on the case for Left, Right, and Right 
Below.

Drilling the hole through the wall for left rear or right rear 
installation

2.5

 

Step 2.5A & 2.5B

 

Measure and mark the location where the piping hole is to be 
drilled.

2.6

 

Step 2.6

 

Drill the piping hole using a hole saw of the correct diameter.
Angle the drill with a downward pitch to the outside wall so 
that the outside hole will be ¼” lower than the inside hole, 
giving the hole the proper angle for condensate drainage.

2.7

 

Step 2.7

 

=  3Y  
inside wall. 
/Z[<\[ 3YA *]  ]
properly behind the wall unit housing.

2.8

 

Step 2.8A & 2.8B

 

Bundle the refrigerant piping, drain piping and wiring with 
tape and pass the bundle through the piping hole.
/Z[<\"* "3^
available in the indoor unit to make the connections to the 
terminal block. 

Step 2.1

Step 2.3

Step 2.2

Step 2.4

Step 2.5B

Step 2.7

Step 2.8B

Step 2.5A

Step 2.6

Step 2.8A

Illustration 1

Piping Exit Options

Rear left

Left

Rear
right

Right

Below

Step 2 - Installation of the Indoor Unit

Attaching the Mounting Plate to the Wall  

Summary of Contents for 1U09ES2VHA

Page 1: ...VHA 1U18TE2VHA 1U24TE2VHA Installation Manual Step 1 Preparation 2 Step 2 Installation of the Indoor Unit 3 Step 3 Installation of the Outdoor Unit 4 Step 4 Interconnecting the Indoor and Outdoor Units 5 n o i t a u c a v E d n a t s e T k a e L 5 p e t S 6 Step 6 Char ging 7 Section 7 Explaining Operation to the End User 8 8 Section 9 S 0010586612 eacoast Application 8 Table of Contents ...

Page 2: ...ation proof mat The marks from to in the gure are the name of the parts The distance between the indoor unit and the oor should be more than 6 feet The models adopt HFC free refrigerant R410A more than 4in more than 4in more than 4in more than 4in more than 4in more than 24in more than 6in A G Arrangement of piping directions Rear left Left Rear right Right Below G Attention must be paid to the pi...

Page 3: ...ear or right rear installation 2 5 Step 2 5A 2 5B Measure and mark the location where the piping hole is to be drilled 2 6 Step 2 6 Drill the piping hole using a hole saw of the correct diameter Angle the drill with a downward pitch to the outside wall so that the outside hole will be lower than the inside hole giving the hole the proper angle for condensate drainage 2 7 Step 2 7 3 Y inside wall Z...

Page 4: ...w to the outdoor unit do so prior to attaching the refrigerant lines and wiring B Step 3 2 Step 3 1 Mounting the Indoor Unit Onto the Wall Plate Electrical Connections for the Indoor Unit 2 11 Step 2 11A 2 11B To make the electrical connections for the indoor unit two cover plates must be removed Raise the front cover to access the screws to remove these covers 2 13 Step 2 13 Access the four condu...

Page 5: ...andard lineset length is 25ft If the installation length is oz ft for the 9K 12K 18K and 24K model Illustration 4 Cut the to lineset to the outdoor unit valves to chart 4 1 Step 4 1 Refrigerant piping connections for the mini split system are use caution to prevent dirt or debris from entering the tubing Remember to place the nut on the pipe before creating the 4 2 Step 4 2 To join the lineset pip...

Page 6: ... no leaks are detected proceed to evacuate the system Step 5 1 Step 5 3 Step 5 2 Step 5 4A Step 5 5A Step 5 6 Step 5 4B Step 5 5B Illustration 5 Leak Test System Evacuation Step 5 Leak Test and Evacuation 5 2 Step 5 2 Attach a manifold gauge micron gauge and vacuum pump Illustration 5 Evacuate the system to 350 microns Close the vacuum pump valve and check the micron gauge If the gauge rises above...

Page 7: ...he atmosphere Refrigerant type R410A GWP value 1975 GWP global warming potential A label supplied with the product B A product charging port e g onto the inside of the stop valve cover Y 3 A Kyoto Protocol B factory refrigerant charge of the product see unit name plate 7 D total refrigerant charge E outdoor unit F refrigerant cylinder and manifold for charging Refrigerant Charge Label System Test ...

Page 8: ... Supply Voltage Cycle P hase V Hz 208 230 60 1 208 230 60 1 208 230 60 1 208 230 60 1 Electrical Data y r a t o R n e v i r D r e t r e v n i C D e p y T r o s s e r p m o C Maximum F use Size A 15 15 30 30 Minimum Circuit Amp A 15 15 18 21 R efriger ate Line Connections Flare Flare Flare Flare Liquid O D in 1 4 1 4 1 4 1 4 Suction O D in 3 8 3 8 1 2 1 2 Factory Charge O z 38 8 38 8 52 2 74 1 Maxi...

Page 9: ... This page intentionally left blank ...

Page 10: ...07470 2017 Haier America Trading LLC 1U18ES2VHA 1U24ES2VHA 1U09ES2VHA 1U12ES2VHA Model AW09ES2VH AW12ES2VH AW18ES2VH AW24ES2VH AW09TE1VH 1U09TE1VHA AW12TE1VH 1U12TE1VHA AW18TE2VH 1U18TE2VHA AW24TE2VH 1U24TE2VHA Issued Date Jan 2017 Update ...

Reviews: