Press the 2 (DIM) key to dim the selected unit or 3 (BRT) to brighten it.  Press a number, 1 - 9 to indicate how many steps you want to 
dim or brighten the unit.  Each step is 10% from its current level. 
 
Press the 4 (LVL) key to set the desired lighting level of the selected unit.  Enter a number (0-100) to indicate the lighting level 
(intensity) of the unit. 
 
Press the 6 (LED) key to turn “On” or “Off” the LED behind the specified button on a 6-Button or 8-Button Keypad Controller.  On 
the 6-Button Keypad Controller: LED 1 is behind the “On” button, LED 2 is behind the “Off” button, and LED 3-6 is behind the A-D 
buttons, respectively.  On the 8-button Keypad Controller: LED 1-8 is behind the E-L buttons, respectively. 
 
Press the 9 (TIM) key to time the selected unit (On, Off, Dim, Brighten).  Timed commands may be from 1-99 seconds, 1-99 minutes 
or 1-18 hours. 
 

Note:

 When the House Code is configured as UPB, ALC switches may be used (they can not share the same unit number); however 

the “Ramp” command cannot be used.  
 

 

Status of a Unit 

 
Press the # (STA) key to see the exact status of a UPB device.  When the ' # ' key is pressed, OmniLT sends a “Status Request” 
message to the selected device for its current state.  The exact state is then displayed. 
 

 

 

Entry Lights   

 

  STATUS 

67%

 

  

Note: 

When a UPB signal is received over the powerline, OmniLT will automatically update the status of the device. 

 
 

All On / Off 

 
UPB devices are not affected by the OmniLT “All On” or “All Off” command.  To achieve this functionality, HAI suggests that you 
program a Link into each device that will respond to an OmniLT “All On” and “All Off” command program.  For example: 
 

In each UPB switch that will respond to “All Off” and “All On”, program a Link (in this example, Link 50 is used) that will 
go to 100% when activated (turned on).  Then write the following programs in the OmniLT controller: 

 

WHEN ALL ON: LINK 50 ON 

 

 

WHEN ALL OFF: LINK 50 OFF 

 
If the “House Code All On” or “House Code All Off” setup item is set to “Yes”, OmniLT will change the status of each unit according 
to the setting.  If House Code All On is set to “Yes”, OmniLT sets the status of all units to “On” (even though it doesn’t explicitly 
send an All On command to those units).  If the “House Code All On” or “House Code All Off” setup item is set to “No”, OmniLT 
will not change the status of each unit.   
 
 

Controlling Links

 

 

OmniLT can turn on (activate), turn off (deactivate), and “set” each of the 250 possible Links.  To issue Link commands, from the 
top-level display or from the main menu, press the 4 (ALL) key on the console keypad, and then press the 3 (LINK) key.  You are 
prompted to enter a Link number. 
 

 

 

ENTER LINK: 

  1-250 

Summary of Contents for OmniLT

Page 1: ...Temperature sensors can be used for outdoors or in attics garages greenhouses basements wine cellars coolers and freezers The temperature can be displayed on the console or spoken over the telephone...

Page 2: ...Page 2...

Page 3: ...multiple RadioRA Switches and Dimmers with one command To control more than one device at one time Phantom Buttons are recommended A Zone is any individual RadioRA Switch or Dimmer A RadioRA System h...

Page 4: ...such as X 10 RadioRA devices can share the same House Code with ALC devices Any unit number that is not being used for an ALC Switch Module may be used for a RadioRA device ALC Switch Modules and Radi...

Page 5: ...n t explicitly send an All On command to those units If the House Code All On or House Code All Off setup item is set to No OmniLT will not change the status of each unit on the House Code Executing P...

Page 6: ...default setting for HC 1 Format is 1 House Code 1 All Off This feature allows you to choose if House Code 1 will respond to the All Off command The default setting for HC 1 All Off is Yes HC 1 ALL OFF...

Page 7: ...ctivated event Additionally you can specify that the event will only activate when a RadioRA Switch or Dimmer is turned on or off or if a button is pressed on a Master Control You are first prompted t...

Page 8: ...Controlling RadioRA Units in this document Program Phantom Button Commands 4 ALL OmniLT can execute a Phantom Button command to set a lighting scene Press the 4 ALL key to execute a Phantom Button com...

Page 9: ...rk ID that serves to link all of the switches modules and keypad controllers to each other and to the OmniLT controller Under the Network ID each device has a unique address The address is used to sen...

Page 10: ...PB UPStart for optimal communications with the OmniLT controller Note Although the UPB protocol is extremely robust and less susceptible to powerline conditions for professional installations HAI reco...

Page 11: ...tate is then displayed Entry Lights STATUS 67 Note When a UPB signal is received over the powerline OmniLT will automatically update the status of the device All On Off UPB devices are not affected by...

Page 12: ...de rate and Wall Switch 2 to go to a different level at a different fade rate The ability to send more than one device to its preset level at a preset fade rate with a single command is known as activ...

Page 13: ...Switch Off 2 242 Switch On 3 243 Switch 1 On 4 244 Switch 2 Off 5 245 Switch 3 A 6 246 Switch 4 B 7 247 Switch 5 C 8 248 Switch 6 D 9 249 Switch 7 10 250 Switch 8 For each UPB Wall Switch Select a wa...

Page 14: ...ontrol settings For complete control of the LEDs by the OmniLT controller select Do Nothing under When this indicator comes on for each Indicator and uncheck all Group options For the 6 Button Keypad...

Page 15: ...Null Null Null No Command Null K Switch 7 Custom Button Null Null No Command Null Null Null No Command Null L Switch 8 Custom Button Null Null No Command Null Null Null No Command Null Transmit Type L...

Page 16: ...pose Mode and UPB transmission format HC 1 FORMAT 1 1 EXTENDED CHNG To change format for House Code 1 press the key then use the arrow keys to scroll through the list of formats Press the key to selec...

Page 17: ...presses and receive Links press the key to bring up a menu of event button types BUTTON TYPE 1 CTRL 2 SEC 3 ZONE 4 ALL 5 ALARM 6 X 10 7 MISC 8 MSG Control Unit Event UPB Switch Press Event Buttons 1...

Page 18: ...roller 8 Button Keypad Controller 1 2 On Button E 2 3 Off Button F 3 4 A G 4 5 B H 5 6 C I 6 7 D J 7 8 K 8 9 L Receive Link Event 4 ALL OmniLT can receive arbitrary Links from devices on the UPB netwo...

Page 19: ...er when the A button on that keypad controller is pressed This program can also be used to illuminate the G button on an 8 Button Keypad Controller when the G button is pressed Program Status Request...

Page 20: ...of units 1 4 WHEN LINK 1 ON RUN GROUP 1 WHEN LINK 2 ON RUN GROUP 1 WHEN LINK 3 ON RUN GROUP 1 WHEN LINK 4 ON RUN GROUP 1 When Link 1 4 On is received on the UPB network the Group 1 button macro is exe...

Reviews: