Press the 2 (DIM) key to dim the selected unit or 3 (BRT) to brighten it. Press a number, 1 - 9 to indicate how many steps you want to
dim or brighten the unit. Each step is 10% from its current level.
Press the 4 (LVL) key to set the desired lighting level of the selected unit. Enter a number (0-100) to indicate the lighting level
(intensity) of the unit.
Press the 6 (LED) key to turn “On” or “Off” the LED behind the specified button on a 6-Button or 8-Button Keypad Controller. On
the 6-Button Keypad Controller: LED 1 is behind the “On” button, LED 2 is behind the “Off” button, and LED 3-6 is behind the A-D
buttons, respectively. On the 8-button Keypad Controller: LED 1-8 is behind the E-L buttons, respectively.
Press the 9 (TIM) key to time the selected unit (On, Off, Dim, Brighten). Timed commands may be from 1-99 seconds, 1-99 minutes
or 1-18 hours.
Note:
When the House Code is configured as UPB, ALC switches may be used (they can not share the same unit number); however
the “Ramp” command cannot be used.
Status of a Unit
Press the # (STA) key to see the exact status of a UPB device. When the ' # ' key is pressed, OmniLT sends a “Status Request”
message to the selected device for its current state. The exact state is then displayed.
Entry Lights
STATUS
67%
Note:
When a UPB signal is received over the powerline, OmniLT will automatically update the status of the device.
All On / Off
UPB devices are not affected by the OmniLT “All On” or “All Off” command. To achieve this functionality, HAI suggests that you
program a Link into each device that will respond to an OmniLT “All On” and “All Off” command program. For example:
In each UPB switch that will respond to “All Off” and “All On”, program a Link (in this example, Link 50 is used) that will
go to 100% when activated (turned on). Then write the following programs in the OmniLT controller:
WHEN ALL ON: LINK 50 ON
WHEN ALL OFF: LINK 50 OFF
If the “House Code All On” or “House Code All Off” setup item is set to “Yes”, OmniLT will change the status of each unit according
to the setting. If House Code All On is set to “Yes”, OmniLT sets the status of all units to “On” (even though it doesn’t explicitly
send an All On command to those units). If the “House Code All On” or “House Code All Off” setup item is set to “No”, OmniLT
will not change the status of each unit.
Controlling Links
OmniLT can turn on (activate), turn off (deactivate), and “set” each of the 250 possible Links. To issue Link commands, from the
top-level display or from the main menu, press the 4 (ALL) key on the console keypad, and then press the 3 (LINK) key. You are
prompted to enter a Link number.
ENTER LINK: