Battery: 
 

A 3 V Lithium Battery powers the unit.  Thanks to the exclusive APS (Automatic Power Saver) characteristics, 
the battery provides about 4 years of continuous operation (depending on the amount of alarms).  If the battery 
reaches a factory preset low level, the “Battery Low” signal will be sent and the detector will remain operational 
for 30 days; giving enough time to replace the battery. 
 

Battery Replacement: 
 

 

Remove screw at the bottom of the case to open. 

 

Take out the old battery. 

 

Using a flat head screwdriver, short the two pins located behind the positive side of the battery holder 
for 10 seconds. This monetary short will discharge all remaining power from the circuits allowing a 
‘fresh’ power up. 

 

Install a new battery according to polarity. 

 

 
CAUTION:

    

 
THERE IS A RISK OF EXPLOSION IF THE BATTERY IS REPLACED BY AN INCORRECT TYPE.  
DISPOSE OF THE USED BATTERIES ACCORDING TO THE INSTRUCTIONS.

 

 
 
Federal Communications Commission (FCC) Statement: 
 

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) 
This device may not cause harmful interference, and (2) this device must accept any interference received, 
including interference that may cause undesired operation. 

Summary of Contents for 47A00-1

Page 1: ...ovement has been detected to sustain the life of the battery Features 60 lb Pet Immune High White Light Immunity 50 x 50 Coverage Quad Element PIR Wall or Ceiling Mount Included Long Range Curtain Opt...

Page 2: ...room and return 5 minutes later the motion will trip So to reiterate after it trips it won t trip again until there has been no motion for 2 3 minutes There is no way to adjust the delay time or opera...

Page 3: ...eas where there are air ducts or substantial airflows Installation on a metal wall The 47A00 1 performs best in a constant and stable environment Mounting the Detector The 47A00 1 can be mounted in a...

Page 4: ...ner mount is desired If the back bracket was installed at the factory and a corner mount was desired the back bracket would need to be removed and 2 holes would then exist There should never be a hole...

Page 5: ...h air drafts or small animals Setting the Pet Immunity Level Slide the switch to 25Kgs for larger pets up to 60 lbs or 15kgs for smaller pets less than 30 lbs Enrolling the 47A00 1 To enroll the 47A00...

Page 6: ...wdriver short the two pins located behind the positive side of the battery holder for 10 seconds This monetary short will discharge all remaining power from the circuits allowing a fresh power up Inst...

Page 7: ...ed 0 3 1 5 m sec Lens Type Spherical Hard Lens Detection Coverage 90 5 50 x 50 Environment Condition Jumper for Normal or Harsh selection Battery Lithium 3V Type CR123A Current Consumption Standby 10...

Reviews: