background image

Fact Section for Pentavalent Arsenic Treatment Appliances 

Arsenic (As) is a naturally occurring contaminant found 
in many ground waters. It generally occurs in two forms 
(valences or oxidation states): pentavalent arsenic (also 
known as As(V), As(+5), or arsenate) and trivalent 
arsenic (also known as As(lll), As(+3), or arsenite). In 
natural ground water, arsenic may exist as trivalent 
arsenic, pentavalent arsenic, or a combination of both. 
Although both forms of arsenic are potentially harmful 
to human health, trivalent arsenic is considered more 
harmful than pentavalent arsenic. More information 
about arsenic and its toxicity can be found on the U.S. 
Environmental Protection Agency Web site at 
http://www.epa.gov/safewater/arsenic.html. 

These appliances (Model Numbers; H3000 and 3500) 
are designed to remove only pentavalent arsenic. 
These appliances do not provide a feature for 
conversion of trivalent arsenic to pentavalent arsenic. 
The appliances may remove some trivalent arsenic; 
however, they have not been evaluated to remove 
trivalent arsenic. 

Trivalent arsenic is generally more difficult to remove 
from drinking water than pentavalent arsenic. Trivalent 
arsenic can be converted to pentavalent arsenic in the 
presence of an effective oxidant such as free chlorine. 
The arsenic in water containing detectable free chlorine 
or that has been treated with another effective oxidant 
will be in the pentavalent arsenic form.¹ Treatment with 
chloramines (combined chlorine) is not sufficient to 
ensure complete conversion of trivalent arsenic to 
pentavalent arsenic. 

Consumers using public water supplies can contact 
their utility to verify whether free chlorine treatment 
chemicals are being used.

¹ Laboratory Study on the Oxidation of Arsenic lll to Arsenic V, 
EPA/600/R-01/021, March 2001 available online at: 
http://www.epa.gov/ORD/publications/ordpubs.html 

Private water supplies and waters that do not have 
detectable free chlorine residuals should be analyzed to 
determine the form(s) of arsenic present and the 
potential need for oxidation of trivalent arsenic to 
pentavalent arsenic. 

Arsenic does not generally impart color, taste, or smell 
to water; therefore, it can only be detected by a 
chemical analytical test. Public water supplies are 
required to monitor treated water for total arsenic 
(trivalent arsenic plus pentavalent arsenic) and the 
results are available to the public from the utility. 
Consumers using private water sources will need to 
make arrangements for testing. A total arsenic test 
usually costs about $15-$30 and it is recommended the 
test be conducted by a certified laboratory. Local health 
departments and environmental protection agencies 
can help provide consumers with a list of certified 
laboratories. Some laboratories may also be able to 
analyze specifically for (speciate) the two forms of 
arsenic present in a water sample if requested. 

These appliances were tested under laboratory 
conditions as defined in NSF/ANSI 58 Reverse 
Osmosis Drinking Water Treatment appliance and were 
found to reduce 0.30 mg/L in the test water to less than 
0.010 mg/L, under standard testing conditions. Actual 
performance of the appliance may vary depending on 
specific water quality conditions at the consumer’s 
installation. Following installation of the appliance, the 
consumer should have the treated water tested for total 
arsenic to verify arsenic reduction is being achieved 
and the appliance is functioning properly. 

The pentavalent arsenic removal component of these 
appliances must be replaced at the end of its useful life 
(approx. 3 years). The replacement component 
#200290 can be purchased from the original source of 
this appliance (retailer or distributor), from other 
sources of these appliances, or directly from the 
manufacturer.

Hague Quality Water 

4343 S. Hamilton Rd.
Groveport, OH 43125 

WaterMax RO Owner’s Manual 

11/11/2009

12

Summary of Contents for WATERMAX H2000

Page 1: ...ER R S S M MA AN NU UA AL L A AN ND D I IN NS ST TA AL LL LA AT TI IO ON N G GU UI ID DE E M MO OD DE EL LS S H H2 20 00 00 0 H H2 25 50 00 0 H H3 30 00 00 0 H H3 35 50 00 0 L LC C3 30 0 L LC C5 50 0...

Page 2: ...y is null and void unless the Hague Appliance was purchased from an independent Hague dealer THERE ARE NO WARRANTIES OTHER THAN THOSE DESCRIBED IN THIS WARRANTY INSTRUMENT This warranty does not cover...

Page 3: ...LLATION AND MAINTENANCE INFORMATION 13 Checklist Before Installation 13 Installation Tool List 14 Installation Diagram 15 Typical Flow Diagram 16 Booster Pump Retrofit Diagrams 17 Installation Steps a...

Page 4: ...ht to make specification and product changes without prior notice This manual is for installation operation and maintenance of the following RO appliance models x WaterMax H2000 x WaterMax H3500 x Wat...

Page 5: ...service this appliance Important Meeting operational maintenance and replacement requirements are essential for this product to perform to specifications Hague recommends that the storage tank be drai...

Page 6: ...g Water Appliances replenish at about one half gallon per hour depending on your tap water pressure and the water temperature Low water pressure and temperature will cause all RO appliances to produce...

Page 7: ...Max RO Drinking Water Appliance is designed to be used on cold water only Never run warm or hot water through your appliance Caution Connect to the cold water supply only Warning Do not allow your app...

Page 8: ...ance Models H2000 H2500 H3000 LC30 LC50 and LC100 If you are using softened water replace your Sediment Pre Filter annually If you are not using softened water the replacement interval will vary Every...

Page 9: ...monitoring devices or water check programs Note If your WaterMax RO appliance is installed on a soft water supply it will greatly increase the life of the membrane Third Stage Carbon Post Filter The A...

Page 10: ...installed where the water source is microbiologically unsafe or of unknown quality without adequate disinfection before and or after the appliance A water source that is not potable relative to waterb...

Page 11: ...ivated carbon as pretreatment for chlorine CAUTION Contaminants in excess of the established limits will require pretreatment WARNING Do not use with water that is microbiologically unsafe or of unkno...

Page 12: ...blications ordpubs html Private water supplies and waters that do not have detectable free chlorine residuals should be analyzed to determine the form s of arsenic present and the potential need for o...

Page 13: ...bing codes To prevent back siphoning provide an adequate air gap or a siphon break See Installation Steps and Start Up Procedures Water Characteristics pH The appliance requires a pH of between 5 0 an...

Page 14: ...ank for non air gap spigot Air pressure test gauge 1 20 psi 1 inch High speed drill bit with 1 2 inch shank for air gap spigot 7 8 inch chassis punch 1 2 inch Drill motor for 1 inch high speed drill b...

Page 15: ...tallation Diagram Notes 1 For maximum flow keep yellow tubing to tank and blue tubing to spigot as short as practical 2 Install feed water line on COLD WATER LINE ONLY 3 Installation procedures for th...

Page 16: ...Typical Flow Diagram Air Gap Silencer for H3500 and H2500 Figure 3 WaterMax H3500 Flow Diagram WaterMax RO Owner s Manual 11 11 2009 16...

Page 17: ...rofit Diagrams WaterMax H2000 For retrofit instructions see form F0873 Figure 4 WaterMax H2000 WaterMax H3000 For retrofit instructions see form F0874 Figure 5 WaterMax H3000 WaterMax RO Owner s Manua...

Page 18: ...ameter be free of score marks and that burrs and sharp edges be removed before inserting into fitting Insert the locking clip The locking clip secures the collet in its position to prevent an accident...

Page 19: ...ron sink A Mark the sink location for the center of the faucet Be sure the location you select is not over a reinforcing rib Check the location from below B Grind away a 1 1 4 inch diameter circle in...

Page 20: ...4 inch black tube onto the small hose barb on the base of the spigot C Slip one end of the loose 3 8 inch black tube over the large hose barb on the base of the spigot Installation Tip To make it eas...

Page 21: ...ect the riser tube to the other end of the feed water supply valve Do not overtighten Caution A longer riser tube assembly will be required if a gentle loop cannot be made See Figure 8 E Remove the re...

Page 22: ...el off the white backing from the drain gasket and apply the gasket to the port connection of the drain saddle See Figure 15 Make sure to align the drain saddle to the drilled hole Attach the drain sa...

Page 23: ...place B Turn on the feed water and check for leaks C Open the valve on top of the storage tank D The appliance is now in operation tep 9 Operation Procedure A Operation of the appliance will require t...

Page 24: ...visibly dirty discard it 6 Wash out the filter housing using warm soapy water and rinse thoroughly 7 Sanitize the appliance See Sanitizing the WaterMax RO Appliance 8 Be sure the O Ring is properly s...

Page 25: ...ater supply valve 3 Lift the black handle of the dispensing spigot and wait at least five minutes for the pressure to be relieved from the system 4 Remove the Carbon Pre Filter housing by turning it c...

Page 26: ...the O Rings on the pressure vessel end cap and lubricate with glycerin Replace if damaged or out of round 10 Replace the end cap by turning clockwise 11 Reattach the tubing to the pressure vessel end...

Page 27: ...d then rinse thoroughly with clear water to flush away any soap residue Note Be sure all carbon pre and post filters are removed during the sanitizing procedure 4 Insert the new cartridge s for the sp...

Page 28: ...bottlebrush and then rinse thoroughly with clear water to flush away any soap residue 2 Insert the new cartridge for the specified model Caution Do not touch the filter with your bare hands Peel the w...

Page 29: ...ts Feed Water Service Valve Assembly 2 1 Figure 13 Feed Water Assembly Part Description Quantity 1 200540 Feed Water Service Valve Assembly 1 2 200200 1 4 inch Locking clip 1 WaterMax RO Owner s Manua...

Page 30: ...O Air Gap Spigot Lead Free Part Description Quantity 1 202310 Filter housing wrench 1 2 200350 Air gap spigot assembly 1 3 200360 Spigot adapter 3 8 inch x 7 16 inch J G 1 4 200199 Locking clip 3 8 in...

Page 31: ...arts Cont Drain Saddle Assembly Figure 15 Drain Saddle Assembly Part Description Quantity 1 200130JG Drain saddle assembly 2 Piece Plastic 1 2 200199 3 8 inch Locking clip 1 WaterMax RO Owner s Manual...

Page 32: ...Assembly and Parts Cont RO Assembly Front View Figure 16 RO Assembly Front View WaterMax RO Owner s Manual 11 11 2009 32...

Page 33: ...12 inch H3000 H3500 LC30 1 15 200191 Inline nitrate filter Optional 1 16 201165 Pressure vessel O Ring 1 17 200300 CTA membrane 16 GPD H2000 H2500 1 18 200290 TFC membrane 24 GPD H3000 H3500 1 19 2002...

Page 34: ...Assembly and Parts Cont RO Assembly Back View Figure 17 RO Assembly Back View WaterMax RO Owner s Manual 11 11 2009 34...

Page 35: ...1 4 inch x 1 4 inch 1 9 202356 Reducing tee 3 8 inch x 3 8 inch x 1 4 inch Plastic 1 10 PAMC Mounting clip permeate pump 1 11 PAM1000 Permeate pump H2500 H3500 LC50P LC100P 1 12 200095 16 Flow restri...

Page 36: ...Assembly and Parts Cont RO Assembly Top Back View Figure 18 RO Assembly Top Back View WaterMax RO Owner s Manual 11 11 2009 36...

Page 37: ...99 Locking clip 3 8 inch 3 9 90816 Male elbow 3 8 inch x 1 4 inch Plastic 1 10 202349 Plug in elbow 1 4 inch tube x 1 4 inch Stem 3 11 200245CJG Membrane housing cap black with O Ring 1 12 201030 Male...

Page 38: ...rage Tank Assembly Part Description Quantity 1 201140 Tank shutoff valve 3 8 inch x 1 4 inch plastic 1 2 200199 3 8 inch Locking clip 1 3 200100 RO storage tank 3 1 gallon capacity black 1 4 200030 Ta...

Page 39: ...p Kit P N PAB6800KIT Figure 20 Parts Booster Pump Kit Part Description Quantity 1 PAB6800 Booster pump 1 2 PAT115 Transformer 24VAC 1 3 PAW260 Pressure switch 1 4 200910 1 4 inch x 5 foot tubing red 1...

Page 40: ...pump 1 202349 Plug in elbow 1 4 inch tube x 1 4 inch stem 4 PAMC Mounting clip permeate pump 1 200500 Screw 10 32 x 1 2 inch Phillips 2 200501 Hex nut 10 32 Nylock 2 PAMASV Permeate pump shut off valv...

Page 41: ...ater shut off Turn on your feed water valve Low feed pressure See Filter Specifications chart to verify minimum feed pressure for your model A pre filter cartridge clogged Replace the clogged pre filt...

Page 42: ...cube mold shape make cubes manually if using automatic Let water sit to release dissolved air before freezing RO membrane is bad Membrane fouled hydrolyzed ruptured or attacked by bacteria Replace mem...

Page 43: ...bon Block 5 Micron Sediment GAC 5 Micron 20 inch Sediment GAC 5 Micron 20 inch Sediment GAC PCF N A N A Standard Standard Standard N A N A Postfilter GAC GAC GAC GAC GAC GAC GAC Height inches 15 1 4 1...

Page 44: ...Certificates WaterMax RO Owner s Manual 11 11 2009 44...

Page 45: ...Certificates Cont WaterMax RO Owner s Manual 11 11 2009 45...

Page 46: ...Notes...

Page 47: ...Notes...

Page 48: ...uality Association This validation assures that all electrical components are UL or CSA listed and all components that are in contact with the treated water are FDA or NSF listed Hague Quality Water I...

Reviews: