RO Specifications
Model Part #
H2000
2056U
H2500
2256U
H3000
1
3146U
H3500
1
2246U
LC 30
N/A
LC 50/50P
N/A
LC 100/100P
N/A
Membrane
CTA
CTA
TFC
TFC
TFC
TFC
TFC
Production Rates
Gallons per day
2
Liters per day
2
WQA GPD
3
WQA LPD
3
16
60.5
N/A
N/A
16
60.5
N/A
N/A
N/A
N/A
13
49
N/A
N/A
13
49
30
50
N/A
N/A
50
189
N/A
N/A
100
378
N/A
N/A
Water Pressure
(Min-Max)
40–100
40–100
40–100
40–100
40–100
40–100
40–100
Water Temperature
Degrees, F (Min-Max)
40–85
40–85
40–113
40–113
40–113
40–113
40–113
Chlorine Tolerance
(ppm)
0.5–1.5
0.5–1.5
0
0
0
0
0
Max. Hardness (Gr. pg)
10
10
10
10
10
10
10
Max. Iron (ppm)
< 0.1
< 0.1
< 0.1
< 0.1
< 0.1
< 0.1
< 0.1
Max. Mang. (ppm)
< 0.05
< 0.05
< 0.05
< 0.05
< 0.05
< 0.05
< 0.05
pH Limit
5.0–9.0
5.0–9.0
4.0–11.0
4.0–11.0
4.0–11.0
4.0–11.0
4.0–11.0
Max. TDS Limit (ppm)
1200
1200
2000
2000
2000
2000
2000
Hydrogen Sulfide (ppm)
0.00
0.00
0.00
0.00
0.00
0.00
0.00
Max. Turbidity (NTU)
1.0
1.0
1.0
1.0
1.0
1.0
1.0
TDS Rejection
Typical @ 60 psi
WQA @ 50 psi
95%-97%
N/A
95%-97%
N/A
N/A
96.7%
N/A
96.2%
97%–98%
N/A
97%–98%
N/A
97%–98%
N/A
Storage (Gal.)
3.1
3.1
3.1
3.1
3.1
Optional
Optional
Water Supply
Municipal,
Chlorinated
Municipal,
Chlorinated
Municipal,
Well, Non-
Chlorinated
Municipal,
Well, Non-
Chlorinated
Municipal,
Well, Non-
Chlorinated
Municipal,
Well, Non-
Chlorinated
Municipal,
Well, Non-
Chlorinated
Treatment Stages 3
3
5
5
5
4
4
4
4
Prefiltration
5 Micron
Sediment
5 Micron
Sediment
5 Micron
Sediment,
GAC
1 Micron
Sediment/
Carbon Block
5 Micron
Sediment,
GAC
5 Micron,
20
-inch
Sediment,
GAC
5 Micron,
20
-inch
Sediment,
GAC
PCF
N/A
N/A
Standard
Standard
Standard
N/A
N/A
Postfilter GAC
GAC
GAC
GAC
GAC
GAC
GAC
Height (inches)
15 1/4
15 1/4
16 3/4
16 3/4
16 3/4
28
28 3/4
Width (inches)
14 1/2
14 1/2
14 1/2
14 1/2
14 1/2
14 1/2
14 1/2
Depth (inches)
7
7
7
7
7
7
7
Weight
29 lb
29 lb
35 lb
35 lb
35 lb
38 lb
40 lb
Efficiency Rating
5
N/A
N/A
13% 17.9% N/A
N/A
N/A
Recovery Rating
6
N/A
N/A
24% 21.4% N/A
N/A
N/A
1
H3000 and H3500 are certified by WQA to NSF/ANSI 58 for the specific performance
claims as verified and substantiated by the test data. These are the only units certified
by WQA.
2
Product output is measured to atmosphere with feed water of 77 degrees F, 60 PSIG
and 360 ppm TDS.
3
WQA production is measured against a pressure tank @ 5 psi backpressure,
77 degrees F, 50 PSIG and 750 mg/L ± 40 mg/L TDS,
1 NTU turbidity 7.5 ± 0.5 pH, 1 US/cm.
4
LC50P and LC100P use dual function prefilter for chlorine taste and odor removal.
Note:
Actual production rates may vary depending on water temperature, pressure, TDS
level and membrane type.
5
Efficiency Rating means the percentage of the influent water to the system that is
available to the user as reverse osmosis treated water under operating conditions that
approximate typical daily usage.
6
Recovery Rating means the percentage of the influent water to the membrane portion of
the system that is available to the user as reverse osmosis treated water when the
system is operating without a storage tank or when the storage tank is bypassed.
WaterMax RO Owner’s Manual
11/11/2009
43