Model 410
Owner’s Manual
6/24/2014
20
Service Settings, Cont.
Display
Meaning
Possible Values
Comments
Hard. Gr.
(Hard. mg/L 00300)
018
Hardness of the water that
was tested
001 to 999 Grains
(0001 to 9999 mg/L)
This is the actual hardness reading
and is not compensated for iron
Iron ppm
(Iron mg/L)
00
Amount of iron in parts per
million of the water that was
tested
00 to 99 ppm (mg/L)
This value is used to calculate
compensated hardness automatically
Mang. ppm
(Mang. mg/L 00)
00
Amount of manganese in
parts per million of incoming
water
00 to 99 ppm (mg/L)
This value is used to calculate
compensated hardness automatically
Salt =
Sodium Regenerant filling the brine
cabinet
Sodium or Potassium
See
Warning
below
Comp. Hard.
(Comp. Hard. 00300)
00018
Compensated hardness
using the hardness, iron,
and manganese settings
Cannot be set
ppm or mg/L
The formula used is:
Ha (4 x each ppm iron)+
(4 x each ppm manganese) =
compensated hardness
Capac. Gr.
(Capac. gm. 0400)
06173
The desired softening
capacity number
00000 to 99999 Grains
(0000 to 9999 gm)
72–96 hr Regen
Yes
A way to force regeneration
at regularly-scheduled
intervals
No (or Yes, for iron)
See
72–96 Hour Regeneration
Backwash 1
00.0
Number of minutes the first
backwash cycle lasts
00.0 to 99.9
Set to the nearest tenth of a minute
Brine/Rinse
09.0
Number of minutes the brine
and slow rinse cycle lasts
00.0 to 99.9
Set to the nearest tenth of a minute
Backwash 2
02.0
Number of minutes the
second backwash cycle
lasts
00.0 to 99.9
Set to the nearest tenth of a minute
Salt lbs.
(Salt kg 00.7)
01.5
Amount of salt set to be
used in each regeneration to
achieve the capacity setting
00.0 to 99.9 lb (kg)
Set to the nearest tenth
Turbine Test
No
Used by qualified personnel
for diagnostic purposes
No or Yes
WARNING: Do not engage this
feature
Reg. Tonight
No
Sets the appliance to
regenerate tonight
No or Yes
If set to Yes, it will force a
regeneration at the next set
regeneration time (such as
02:00 a.m.). After the regeneration,
the value will be set to No
RO Comp?
No
Used when an RO system is
also installed
No or Yes
If set to Yes, the capacity will be
adjusted slightly to compensate water
use from an RO system
When you press the P button at “RO Comp?,” the values are saved, and the controller returns to Normal
operating mode.
Warning:
When iron and/or manganese is present in the water supply, do not use potassium chloride as a
regenerant. Iron and/or manganese bacteria may develop and foul the conditioning media and may
void the warranty.