background image

HAGOR Products GmbH | Oberbecksener Straße 97 | D-32547 Bad Oeynhausen | Telefon: +49(0)57 31-7 55 07-0 | Mail: [email protected]

Tastbedienung | Remote control

Hand control function: 
 

UP key

: Press the button, the column rises, press the button again to stop the column or stop at 

the upper limit; 

 

DOWN key

: Press the button, the column descends, press the button again to stop or stop at the 

lower limit;  

 

Upper  limit  setting

: Simultaneously press and hold the UP key + STUDY key. After the red 

indicator light starts to flash rapidly for 3 seconds (the blinking interval is about 0.5s), the column 
starts to rise. The red indicator flashes quickly (the blinking interval is about 0.25s). Release the 
button. Stop the red indicator light to stop flashing, the position where the column stops is set to 
the upper limit;  

Lower limit setting

: Simultaneously hold down the DOWN key +STUDY key, the red indicator light starts to flash rapidly 

after 3 seconds 0.5s), the column starts to fall and the red indicator flashes quickly (the blinking interval is about 0.25s), 
release the button to stop the red indicator to stop flashing, and the position where the column stops is set to the lower 
limit;  

The upper and lower limit settings are cancelled

: Press and hold the STUDY button for 5 seconds. After the red indicator 

light flashes twice quickly (the flashing interval is about 0.25s), the upper and lower limit set manually will be cancelled. 
The upper and lower limit settings can be remembered after power-off, that is, after setting, power-off and power-on 
remain.  

Reset function

: If the red indicator light on the hand controller flashes quickly (the flashing interval is about 0.5s, which 

is different from the slow flashing every 3S during working protection), the system is in the reset state and needs to 
complete the reset operation to move up and down. The specific operation is as follows: press and hold the RESET button 
of the hand control, the push rod descends, and runs to the bottom, then the push rod is raised 7mm, and the small light 
goes out, the reset action is completed. During the entire reset process, the RESET key must be kept pressed. At the same 
time, the LED light on the hand controller flashes quickly during the entire reset process. When the LED light is off, it 
indicates that the reset is complete.  

Remarks:  
1).

 When the system enters the reset state, that is, during the reset process, all buttons except the "RESET" button on the 

hand controller will not work. 

 

2).

 When the push rod enters the abnormal state, the red indicator light is always on. Press and hold the RESET key for 

5s. The push rod enters the reset state (if the RESET key is pressed and held for less than 5s, it will not work). 

 

3).

 During normal operation of the push rod, pressing the RESET key will stop the push rod; if the RESET key is pressed at 

the lower limit for more than 5s, the push rod will request an active reset.  

 
Working  system  protection:

  The column will continue to work for 3 minutes to protect the working system. After 

protection, all keys will not work, and normal operation can only be restored after a 16-minute rest. After the system 
enters the working system protection, the indicator on the hand controller flashes slowly every 3 seconds to indicate the 
status.  

Back-off function in case of resistance:

 When the system is operating normally, the column will stop when it encounters 

a foreign object during the lifting process, and will perform the reverse movement opposite to the movement direction. 
This function is still effective during the upper and lower limit setting process. 5. Battery function no.  

Overcurrent protection: 

The column overcurrent protection value is 10

±

1A. 7. Overheat protection Overheat protection 

value: 75

; recover when it is lower than 45

UP-Taste: 

Drücken Sie die Taste, der Lift fährt hoch, drücken Sie die Taste erneut, um den Lift zu stoppen oder an der oberen Endposition anzuhalten.

DOWN-Taste:

 Drücken Sie die Taste, der Lift fährt runter, drücken Sie die Taste erneut, um anzuhalten oder an der unteren Endposition anzuhalten.

Einstellung der oberen Endposition: Halten Sie gleichzeitig die UP-Taste + die STUDY-Taste gedrückt. Nachdem die rote Anzeigelampe 3 Sekunden lang schnell 
zu blinken beginnt (das Blinkintervall beträgt ca. 0,5 s), beginnt der Lift hochzufahren. Die rote Anzeige blinkt schnell (das Blinkintervall beträgt ca. 0,25 s). Lassen 
Sie den Knopf los. Stoppen Sie die rote Anzeigelampe, um das Blinken zu beenden. Die Position, an der der Lift stoppt, ist auf asl oberere Endposition eingestellt.

Einstellung der unteren Endposition: 

Halten Sie gleichzeitig die Taste DOWN + STUDY gedrückt, die rote Anzeigelampe beginnt nach 3 Sekunden (0,5 Sekun-

den) schnell zu blinken, der Lift fährt runter und die rote Anzeige blinkt schnell (das Blinkintervall beträgt ca. 0,25 Sekunden). Lassen Sie die Taste los, um die rote 
Anzeige zu stoppen und das Blinken zu stoppen. Die Position, an der der Lift stoppt, wird als untere Endposition eingestellt.

Die Einstellungen für die obere und untere Endposition aufheben: 

Halten Sie die STUDY-Taste 5 Sekunden lang gedrückt. Nachdem die rote Anzeigelampe 

zweimal schnell blinkt (das Blinkintervall beträgt ca. 0,25 s), werden die manuell eingestellten Endpositionen aufgehoben. Die Einstellungen für die obere und 
untere Endposition können nach dem Ausschalten gespeichert werden, d.h nach dem Abschalten bleibt die Posiotn gespeichert.

Reset-Funktion: 

Wenn die rote Anzeigelampe der Tastbedienung schnell blinkt (das Blinkintervall beträgt ca. 0,5 s, was sich vom langsamen Blinken alle 3 Sekun-

den während des Arbeitsschutzes unterscheidet), befindet sich das System im Reset-Zustand und muss den Reset abschließen Bedienung zum Auf- und Abbewe

-

gen. Die spezifische Operation ist wie folgt: Halten Sie die RESET-Taste der Tastbedienung gedrückt, die Schubstange senkt sich und läuft nach unten, dann wird 
die Schubstange um 7 mm angehoben und das kleine Licht erlischt, der Rücksetzvorgang ist abgeschlossen. Während des gesamten Rücksetzvorgangs muss die 
RESET-Taste gedrückt gehalten werden. Gleichzeitig blinkt die LED an der Tastbedienung während des gesamten Rücksetzvorgangs schnell. Wenn die LED nicht leuchtet, zeigt dies an, dass 
der Reset abgeschlossen ist.

Bemerkungen:

1). Wenn das System in den Reset-Zustand wechselt funktionieren alle Tasten außer der Taste „RESET“ auf der Tastbedienung nicht.
2). Wenn die Schubstange in den abnormalen Zustand übergeht, leuchtet die rote Anzeigelampe immer. Halten Sie die RESET-Taste 5 Sekunden lang gedrückt. Die Schubstange geht in den 
Reset-Zustand über (wenn die RESET-Taste weniger als 5 Sekunden lang gedrückt gehalten wird, funktioniert sie nicht).
3). Während des normalen Betriebs der Schubstange stoppt das Drücken der RESET-Taste die Schubstange. Wenn die RESET-Taste länger als 5 Sekunden an der unteren Grenze gedrückt 
wird, fordert die Schubstange einen aktiven Reset an.

Schutz des Arbeitssystems: 

Der Lift arbeitet 3 Minuten lang weiter, um das Arbeitssystem zu schützen. Nach dem Schutz funktionieren nicht alle Tasten und der normale Betrieb kann erst nach einer Pause von 16 Minuten 
wiederhergestellt werden. Nachdem das System in den Schutz des Arbeitssystems eingetreten ist, blinkt die Anzeige auf der Handsteuerung alle 3 Sekunden langsam, um den Status anzuzei

-

gen.

Rückschaltfunktion bei Widerstand: 

 

Wenn das System normal arbeitet, stoppt der Lift, wenn sie während des Hebevorgangs auf einen Widerstand trifft, und führt die entgegengesetzte Bewegung entgegen der Bewegungsrichtung 

aus. Diese Funktion ist während des Einstellvorgangs für die obere und untere Endposition weiterhin wirksam. 5. Batteriefunktion Nr. 

Überstromschutz: 

Der Wert für den Überstromschutz der Säule beträgt 10 ± 1A. 

Überhitzungsschutz: 

Überhitzungsschutzwert: 75°C; Wiederaufnahme des Betriebs wenn die Temperatur wieder niedriger als 45°C ist.

---

UP key: 

Press the button, the column rises, press the button again to stop the column or stop at the upper limit;

DOWN key: 

Press the button, the column descends, press the button again to stop or stop at the lower limit;

Upper limit setting: 

Simultaneously press and hold the UP key + STUDY key. After the red indicator light starts to flash rapidly for 3 seconds (the blinking interval is about 0.5s), the column 

starts to rise. The red indicator flashes quickly (the blinking interval is about 0.25s). Release the button. Stop the red indicator light to stop flashing, the position where the column stops is set to 

the upper limit;

Lower limit setting: 

Simultaneously hold down the DOWN key +STUDY key, the red indicator light starts to flash rapidly after 3 seconds 0.5s), the column starts to fall and the red indicator 

flashes quickly (the blinking interval is about 0.25s), release the button to stop the red indicator to stop flashing, and the position where the column stops is set to the lower limit;

The upper and lower limit settings are cancelled: 

Press and hold the STUDY button for 5 seconds. After the red indicator light flashes twice quickly (the flashing interval is about 0.25s), the 

upper and lower limit set manually will be cancelled. The upper and lower limit settings can be remembered after power-off, that is, after setting, power-off and power-on remain.

Reset function: 

If the red indicator light on the hand controller flashes quickly (the flashing interval is about 0.5s, which is different from the slow flashing every 3S during working protection), the 

system is in the reset state and needs to complete the reset operation to move up and down. The specific operation is as follows: press and hold the RESET button of the hand control, the push 

rod descends, and runs to the bottom, then the push rod is raised 7mm, and the small light goes out, the reset action is completed. During the entire reset process, the RESET key must be kept 

pressed. At the same time, the LED light on the hand controller flashes quickly during the entire reset process. When the LED light is off, it indicates that the reset is complete.

Remarks:

1). When the system enters the reset state, that is, during the reset process, all buttons except the „RESET“ button on the hand controller will not work.

2). When the push rod enters the abnormal state, the red indicator light is always on. Press and hold the RESET key for 5s. The push rod enters the reset state (if the RESET key is pressed and 

held for less than 5s, it will not work).

3). During normal operation of the push rod, pressing the RESET key will stop the push rod; if the RESET key is pressed at the lower limit for more than 5s, the push rod will request an active 

reset.

Working system protection: 

The column will continue to work for 3 minutes to protect the working system. After protection, all keys will not work, and normal operation can only be restored after a 16-minute rest. After the 

system enters the working system protection, the indicator on the hand controller flashes slowly every 3 seconds to indicate the status.

Back-off function in case of resistance: 

When the system is operating normally, the column will stop when it encounters a foreign object during the lifting process, and will perform the reverse movement opposite to the movement 

direction. This function is still effective during the upper and lower limit setting process. 5. Battery function no.

Overcurrent protection: 

The column overcurrent protection value is 10±1A. 

Overheat protection: 

Overheat protection value: 75°C; recover when it is lower than 45°C.

Summary of Contents for Mobile Lift Pro Light

Page 1: ...07 0 Mail hagor hagor de Installationsanleitung Mobile Lift Pro Light Floorstand Lift Pro Light Wall Lift Pro Light II DE Installationsanleitung ES Gu a de instalaci n GB Installation manual FR Guide...

Page 2: ...setzen Sie diese bei Bedarf durch geeignete Materialien Falls Sie Bez glich der Installation des Produkts unsicher sind oder noch Fra gen haben wenden Sie sich an uns oder anderes ausgebildetes Fachpe...

Page 3: ...OR Products GmbH Oberbecksener Stra e 97 D 32547 Bad Oeynhausen Telefon 49 0 57 31 7 55 07 0 Mail hagor hagor de Bitte beachten Please note MONTAGE ZU ZWEIT DURCHF HREN DO THE INSTALLATION WITH 2 PERS...

Page 4: ...07 0 Mail hagor hagor de Mobile Lift Pro Light M Floorstand Lift Pro Light F M8x12 4x M6x12 4x M6x8 M 10x F 10x W 12x M8 4x M6 M 4x W 8x M6 M 4x M10 M 4x 6 1x 5 1x 1x Wall Lift Pro Light II W Nicht en...

Page 5: ...HAGOR Products GmbH Oberbecksener Stra e 97 D 32547 Bad Oeynhausen Telefon 49 0 57 31 7 55 07 0 Mail hagor hagor de 1 M 2 M S D E A P T...

Page 6: ...HAGOR Products GmbH Oberbecksener Stra e 97 D 32547 Bad Oeynhausen Telefon 49 0 57 31 7 55 07 0 Mail hagor hagor de 1 M 2 M 2 W 2 F G D A J G D A J G D...

Page 7: ...HAGOR Products GmbH Oberbecksener Stra e 97 D 32547 Bad Oeynhausen Telefon 49 0 57 31 7 55 07 0 Mail hagor hagor de Auf beiden Seiten verschrauben Screw on both sides 3 M 3 F L L L L R...

Page 8: ...HAGOR Products GmbH Oberbecksener Stra e 97 D 32547 Bad Oeynhausen Telefon 49 0 57 31 7 55 07 0 Mail hagor hagor de Auf beiden Seiten verschrauben Screw on both sides 3 W 4 M F W L R K M B...

Page 9: ...HAGOR Products GmbH Oberbecksener Stra e 97 D 32547 Bad Oeynhausen Telefon 49 0 57 31 7 55 07 0 Mail hagor hagor de 5 W L WAND WALL...

Page 10: ...97 D 32547 Bad Oeynhausen Telefon 49 0 57 31 7 55 07 0 Mail hagor hagor de 6 M F W Stellen Sie alle ben tigten Steckverbindungen her aber schalten Sie diese noch nicht ein Make all the necessary plug...

Page 11: ...O A A C O A A Schalten Sie das System ein und fahren Sie es mit Hilfe der Tastbedienung in die oberste Position Pr fen Sie die Verkabelung und befreien Sie ggf verknotete oder eingeklemmte Kabel Switc...

Page 12: ...W 1 2 3 1 2 3 1 2 3 L sen Sie auf beiden Seiten die Schrauben und schieben Sie die Sicherung nach unten um den Bildschirm einh ngen zu k nnen Loosen the screws on both sides and slide the lock down t...

Page 13: ...h das System im Reset Zustand und muss den Reset abschlie en Bedienung zum Auf und Abbewe gen Die spezifische Operation ist wie folgt Halten Sie die RESET Taste der Tastbedienung gedr ckt die Schubsta...

Page 14: ...Sicherheitshinweise f r die Wandmontage des Ger ts Verwenden Sie bitte ausschlie lich geeignetes Befestigungsmaterial Bitte benutzen Sie nur Schrauben die f r die jeweilige Wandbeschaffenheit ausgeleg...

Page 15: ...HAGOR Products GmbH Oberbecksener Stra e 97 D 32547 Bad Oeynhausen Telefon 49 0 57 31 7 55 07 0 Mail hagor hagor de 1299 5 200 2277 5 745 1154 2624 550 613 Mobile Lift Pro Light M...

Page 16: ...HAGOR Products GmbH Oberbecksener Stra e 97 D 32547 Bad Oeynhausen Telefon 49 0 57 31 7 55 07 0 Mail hagor hagor de 7 100 2165 236 700 1043 Floorstand Lift Pro Light F...

Page 17: ...HAGOR Products GmbH Oberbecksener Stra e 97 D 32547 Bad Oeynhausen Telefon 49 0 57 31 7 55 07 0 Mail hagor hagor de 2 25 2160 244 710 285 Wall Lift Pro Light II W...

Page 18: ...HAGOR Products GmbH Oberbecksener Stra e 97 D 32547 Bad Oeynhausen Telefon 49 0 57 31 7 55 07 0 Mail hagor hagor de Optionales Zubeh r Optional accessories...

Page 19: ...HAGOR Products GmbH Oberbecksener Stra e 97 D 32547 Bad Oeynhausen Telefon 49 0 57 31 7 55 07 0 Mail hagor hagor de...

Page 20: ...HAGOR Products GmbH Oberbecksener Stra e 97 D 32547 Bad Oeynhausen Telefon 49 0 57 31 7 55 07 0 Mail hagor hagor de...

Reviews: