January 2018 | Tips & Tricks | 21
XIBU senseTOWEL
Replacing the battery tray
Fig. 2
Fig. 4
Fig. 1: battery tray
Request:
No blinking signal and/or no function!
Possible causes:
The batteries are completely empty
the battery springs are broken
the battery contacts are oxidised
Solution:
Replace the batteries and/or battery tray
Open the cover
remove the paper roll
Open the battery tray by pressing in the 2
tabs of the battery tray (see the arrow on the
battery tray)
(Fig. 2 – 3)
Fig. 3
Fig. 5
After removing the batteries, press in on the
tabs again and push the battery tray all the
way down. (Fig. 4)
Remove the batteries from the holder and re-
place them (Fig. 5)
The installation of the battery tray takes place
in the reverse order.
Spare part name:
BG HT battery case XIBU
Article no.
492011530000