XIBU senseTOWEL
Cover microswitch
Fig. 2
Fig. 4
Fig. 1
Request:
No paper is dispensed despite a green blin-
king LED (no difference whether the cover is
open or closed).
Possible cause:
Microswitch (cover) is not working!
Analysis:
Press and hold the microswitch with a finger
(Fig. 1) now check whether the dispenser is
dispensing paper?
The dispenser is dispensing paper!
Solution:
On the cover swivel joint, remove
screw 2
on
the left and loosen
screw 1
(1 rotation).
Rotate the cover upwards so that the micro-
switch becomes visible (Fig. 2).
Now gently bend the microswitch upwards
using the long nose pliers (Fig. 3 and 4).
It is put back together in the reverse order.
Fig. 3
Tools used:
Phillips screwdriver size PH1
Long nose pliers
20 | Tips & Tricks | January 2018