![Hagie SmarTrax 2100 Series Installation Manual Download Page 9](http://html1.mh-extra.com/html/hagie/smartrax-2100-series/smartrax-2100-series_installation-manual_3201653009.webp)
7
CABLE ROUTING
START-UP PROCEDURES
Check the S.P.S. stroke length to be sure it is not over compressed or over extended.
Turn steering wheel full left and right to purge system of air.
Set valve timing for a left to right and right to left time of 12 to 13 seconds. Use controller to
pulse valve left and right.
Adjust pressure switch to most responsive setting. For additional information, refer to
Universal kit manual.
Access
Hole
Connect wire harness to SPS, left and right valve coils, and pressure switch. Left coil is outer
one, right coil is inner one.
Run harness into cab through access hole at right rear of floor cab.