RE 15345-WA, Version 11.2022, Bosch Rexroth AB
Installation |
Drive system Hägglunds Fusion 31/72
Table 11: External forces torque arm valid for delta pressure 400 bar (5800 psi) static
Hydraulic motor
Electric motor
Force Fb
Force Fr
1)
kN
lbf
kN
lbf
CA 50-50 S
15 kW
10
2250
21
4725
75 kW
10
2250
28
6300
CA 70-70 S
15 kW
14
3150
25
5625
75 kW
14
3150
32
7200
CA 100-100 S
15 kW
20
4500
32
7200
75 kW
20
4500
39
8775
CA 140-140 S
15 kW
28
6300
40
9000
75 kW
28
6300
48
10800
CA 210-210 S
15 kW
42
9450
55
12375
75 kW
42
9450
63
14175
CB 280-280 S
15 kW
56
12600
72
16200
75 kW
56
12600
80
18000
CB 400-400 S
22 kW
80
18000
101
22725
75 kW
80
18000
107
24075
CB 560-560 S
30 kW
113
25425
134
30150
75 kW
113
25425
140
31500
CB 840-840 S
37 kW
169
38025
193
43425
75 kW
169
38025
199
44775
CA 50-50 C
15 kW
10
2250
21
4725
75 kW
10
2250
28
6300
CA 70-70 C
15 kW
14
3150
25
5625
75 kW
14
3150
33
7425
CA 100-100 C
15 kW
20
4500
32
7200
75kW
20
4500
39
8775
CA 140-140 C
15 kW
28
6300
41
9225
75 kW
28
6300
48
10800
CA 210-210 C
15 kW
42
9450
56
12600
75 kW
42
9450
63
14175
CB 280-280 C
15 kW
56
12600
73
16425
75 kW
56
12600
81
18225
CB 400-400 C
22 kW
80
18000
102
22950
75 kW
80
18000
108
24300
CB 560-560 C
30 kW
113
25425
135
30375
75 kW
113
25425
141
31725
CB 840-840 C
37 kW
169
38025
195
43875
75 kW
169
38025
201
45225
1)
The Force Fr is calculated including the total weight of the Fusion unit.