RE 15345-WA, Version 11.2022, Bosch Rexroth AB
Installation |
Drive system Hägglunds Fusion 29/72
7.5.3 Mounting the reaction point (articulated connection)
DANGER
Articulated connection rotates with the motor!
Risk to life and risk of injury or serious
injuries and risk of damage to equipment!
f
Make sure the foundation
and the customer machine can
withstand the forces from the
torque arm. See
f
Do not stand in the danger zone.
WARNING
Heating of material (welding).
Risk of fire, health hazard, damage to equipment, environmental pollution!
f
Only perform welding work when the machine/system is depressurized.
f
The product is painted with thermosetting plastic paint containing an isocyanate
component. When a thermosetting plastic paint is heated to over 150-175°C,
gases are emitted that can cause serious health risk. If hot work (e.g. welding)
is done on the product, protective breathing equipment must be used.
f
Never
use motor as grounding point.
Articulated connection in general
1.
x ≤ ± 2 mm (0,079 inch) misalignment in installation.
x ≤ ± 15 mm (0,59 inch) movement when in use.
2.
The articulated connection and the spherical plain bearing must be dismounted
during welding. See
3.
Steel: EN 10025-3 – S355N (1.0545), shall be protected against corrosion after
welding.
42635
Fig. 10: Installation instruction for articulated connection
2
3
1
Fb
Alternative position
DD00079192
Note!
Grounding
point for
welding