Entry of codes for relay switching
Start code entry
Complete code entry
and start the switching process
The direct-dial keypad module can also be used to implement code lock functions for switching applications such as opening doors.
Here, the relay built into the door module or, by status message, the RTD111X network relay is controlled.
4712
Enter code number
Enter code:
>
Enter code:
>****
Door is open!
Display with display call module
connected (not needed to ex-
ecute the function).
Defining the code function in the RTN300X/301X IP door speaker module
Code numbers to be used to
control relays must be added to
the call destination area in the
IP door speaker module. To do
this, call up the Web interface of
the device and go to the
Expert
configuration
area.
In the
Call destinations menu
,
create the code as a call desti-
nation entry.
Name of call des-
tination
and
SIP ID
are not im-
portant, but they must be filled
in with arbitrary content.
The important point is to enter
the code in
DTMF relay 1
. The
code may only consist of digits
and must be 4 digits long.
Attention:
Do not use any range
of call destinations that is read
out by a display call module.
This code switches relay 1 on
the door speaker module or
the
RTD111X IP network relay. The
code entered applies to
Relay
2
with an
offset of +2
in the
second digit.
The relays to be switched must
appear in the
Relays menu
with
function
DTMF controlled
and
will be switched for the duration
defined here after the code is
input.
Code for
Relay 2 = 4912
If necessary, multiple codes (for example, for different people) can also be created.