Page 4 of 8
2916 Keypad
Installation Instructions
I-EA00080
Rev 9, Rev Date: 7/9/21
Always visit www.hagerco.com for the latest Installation Instructions
HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995
FACTORY DEFAULTS
Master Programming Code………..………………….….…...123456
Entry Code Length……………………………………….……..4 digits
Request-to-exit Output Relay………………………..........No Output
Alarm Shunt Output….………………………………….........Disabled
Forced Entry Output……………………………..…………No Output
Door Ajar Output…………………………………..…….….No Output
Main Relay On Time…………………………………..…..02 Seconds
Auxiliary Relay On Time…………………………….....…02 Seconds
Solid State Output #3 On Time………………………......02 Seconds
Solid State Output #4 On Time…………………………..02 Seconds
Door Sense/Inhibit Input…………………………...…………....Inhibit
Keypad Lockout Output………………………………..…….Disabled
Keypad Active Output………………………………..…..…..Disabled
Beeper Sounds When Key Pressed……………………...………Yes
Beeper Sounds During Relay #1………………………..…...…….No
Beeper Sounds During Relay #2……………………………...…...No
Beeper Sounds During Output #3……………………………........No
Beeper Sounds During Output #4……………………………........No
Keypad Lockout Count……….………......….3 Tries Before Lockout
Anti-Passback Time………………..……...……….No Anti-Passback
Auto-Relock…………………………………...………….………….On
BASIC PROGRAMMING
When the 2916 is in Programming Mode the yellow indicator will
blink slowly. After a programming command is selected, the
yellow indicator will flash rapidly while the keypad is waiting for
user input data. The green indicator will light if the data is
accepted. The red indicator will light if any programming data is
entered incorrectly, and the command will have to be fully re-
entered.
Entering Programming Mode
The 6-digit Master Programming Code (default = 123456) is used
to enter Programming Mode.
Press: # 9 # Master Code #
Master Code = the current 6-digit Master Programming Code
Setting Entry Code Length
Default: 4 digits
Press: 03 #
Length
#
Length = 1-6 for entry code length
Note:
If the Entry Code Length is going to be changed from the factory
default of 4 digits, make this change first before programming any entry
codes.
Adding a New User PIN Code
Press: 01 #
Code
#
Code # Relay #
Code
=The new entry code: 1-999999, depending on code length
Relay
=Relay output entry code will activate:
1=Main Relay 2=Auxiliary Relay 3=Both Relays
10=Relay #1, toggled 20=Relay #2, toggled 30=both Relays
toggled
12=Relay #1 toggled; Relay #2 timed open
21=Relay #1 timed open; Relay #2 toggled
The green indicator will light momentarily when the new code is
accepted. The green indicator will light when the new code is
accepted. If the user number already exists or an entry error has
been made, the red indicator will light. Delete the user and re-
enter the new information again.
Note:
Leading zeros (zeros before the code number, i.e.0001)
do not need to be entered when programming a new code. The
2916 will internally add any zeros to fill digits determined by the
entry code length setting. Leading zeros will have to be entered
by the user when entering their code to gain access.
Erasing a Single User
Press: 02 #
Code
#
Code
#
Code = The PIN code to be deleted
The yellow indicator will flash quickly while the 2916 erases the
PIN code from memory. The green indicator will light when the
code is erased.
Output Toggle Mode
When an output is programmed for Toggle Mode, the output
alternates from OFF to ON or from ON to OFF each time it is
accessed. When an output is toggled on, the green LED remains
solid until toggled off.
The rules for a toggle output are:
If the output is OFF, entering a
toggle
code will turn ON the
selected relay. The selected relay will stay ON until the next
activation of a toggle code.
If the output is ON, entering a
toggle
code will turn OFF the
selected relay. The selected relay will stay OFF until the
next activation of a toggle code.
*An authorized PIN or REX input programmed to
momentarily activate that same relay
WILL NOT
reset the
relay to its normal state.
Re-entering a Command After a Mistake
If the red indicator lights, signaling an incorrect entry, or an
incorrect key is pressed during programming, to clear the
keypad and re-enter the command:
Press:
9 #
*
Exiting Programming Mode
Press:
#
The red indicator will light after exiting Programming Mode
Note:
The 2916 will automatically exit Programming Mode
after 30 seconds of inactivity
**
See the following example that sets entry codes 1234 for normal
operation and 5678 for toggle operation.
Press: 01 # 1234 # 1234 # 1 #
01=Programming Step; 1234=Entry Code; 1=Main Relay
Press: 01 # 5678 # 5678 # 20 #
01=Programming Step; 5678=Entry Code; 20=Auxiliary Relay
toggle
Once all PIN codes are programmed, it is recommended the
default Master Programming Code be chanced using the function
on page 5.