background image

Page 4 of 8

2916 Keypad

Installation Instructions

I-EA00080

Rev 9, Rev Date: 7/9/21

Always visit www.hagerco.com for the latest Installation Instructions

HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995

FACTORY DEFAULTS

Master Programming Code………..………………….….…...123456  
Entry Code Length……………………………………….……..4 digits
Request-to-exit Output Relay………………………..........No Output
Alarm Shunt Output….………………………………….........Disabled
Forced Entry Output……………………………..…………No Output
Door Ajar Output…………………………………..…….….No Output
Main Relay On Time…………………………………..…..02 Seconds
Auxiliary Relay On Time…………………………….....…02 Seconds
Solid State Output #3 On Time………………………......02 Seconds
Solid State Output #4 On Time…………………………..02 Seconds
Door Sense/Inhibit Input…………………………...…………....Inhibit
Keypad Lockout Output………………………………..…….Disabled
Keypad Active Output………………………………..…..…..Disabled
Beeper Sounds When Key Pressed……………………...………Yes
Beeper Sounds During Relay #1………………………..…...…….No
Beeper Sounds During Relay #2……………………………...…...No
Beeper Sounds During Output #3……………………………........No
Beeper Sounds During Output #4……………………………........No
Keypad Lockout Count……….………......….3 Tries Before Lockout
Anti-Passback Time………………..……...……….No Anti-Passback
Auto-Relock…………………………………...………….………….On

BASIC PROGRAMMING

When the 2916 is in Programming Mode the yellow indicator will 
blink slowly.  After a programming command is selected, the 
yellow indicator will flash rapidly while the keypad is waiting for 
user input data.  The green indicator will light if the data is 
accepted.  The red indicator will light if any programming data is 
entered incorrectly, and the command will have to be fully re-
entered. 

Entering Programming Mode

  

The 6-digit Master Programming Code (default = 123456) is used 
to enter Programming Mode.

Press:  # 9 # Master Code #

Master Code = the current 6-digit Master Programming Code

Setting Entry Code Length

Default: 4 digits

Press: 03 # 

Length

 

 #  

Length = 1-6 for entry code length

  

Note: 

If the Entry Code Length is going to be changed from the factory 

default of 4 digits, make this change first before programming any entry 
codes.

Adding a New User PIN Code

Press: 01 #  

Code

 #  

Code #  Relay #

Code

=The new entry code: 1-999999, depending on code length

Relay

=Relay output entry code will activate:

 

1=Main Relay   2=Auxiliary Relay   3=Both Relays
10=Relay #1, toggled  20=Relay #2, toggled  30=both Relays 
toggled
12=Relay #1 toggled; Relay #2 timed open
21=Relay #1 timed open; Relay #2 toggled

The green indicator will light momentarily when the new code is 
accepted.  The green indicator will light when the new code is 
accepted. If the user number already exists or an entry error has 
been made, the red indicator will light.  Delete the user and re-
enter the new information again.

Note:

  Leading zeros (zeros before the code number, i.e.0001) 

do not need to be entered when programming a new code.  The 
2916 will internally add any zeros to fill digits determined by the 
entry code length setting.  Leading zeros will have to be entered 
by the user when entering their code to gain access.

Erasing a Single User

Press: 02 #  

Code 

#  

Code

 

#  

Code = The PIN code to be deleted

The yellow indicator will flash quickly while the 2916 erases the 
PIN code from memory.  The green indicator will light when the 
code is erased.

Output Toggle Mode

When an output is programmed for Toggle Mode, the output 
alternates from OFF to ON or from ON to OFF each time it is 
accessed.  When an output is toggled on, the green LED remains 
solid until toggled off.

The rules for a toggle output are:

 

If the output is OFF, entering a 

toggle 

code will turn ON the 

selected relay.  The selected relay will stay ON until the next 
activation of a toggle code.

 

If the output is ON, entering a 

toggle 

code will turn OFF the 

selected relay.  The selected relay will stay OFF until the 
next activation of a toggle code.

 

*An authorized PIN or REX input programmed to 
momentarily activate that same relay 

WILL NOT

 reset the 

relay to its normal state.

Re-entering a Command After a Mistake

  

If the red indicator lights, signaling an incorrect entry, or an 
incorrect key is pressed during programming, to clear the 
keypad and re-enter the command:

Press:     

 

 9 #  

*

Exiting Programming Mode

Press:       

 

The red indicator will light after exiting Programming Mode

Note: 

 The 2916 will automatically exit Programming Mode 

after 30 seconds of inactivity

**

  
See the following example that sets entry codes 1234 for normal 
operation and 5678 for toggle operation.

Press:  01 #  1234 #  1234 #  1 #

01=Programming Step;  1234=Entry Code;  1=Main Relay

Press:  01 #  5678 #  5678 #  20 #

01=Programming Step;  5678=Entry Code;  20=Auxiliary Relay

                                                                  toggle

Once all PIN codes are programmed, it is recommended the 
default Master Programming Code be chanced using the function 
on page 5.

Summary of Contents for 2916

Page 1: ...it the input can be wired to a normally open service switch or automatic timer that will disable access while the switch is closed The REQUEST TO EXIT input can be wired to a normally open pushbutton to provide codeless activation of the Main Relay Auxiliary Relay Output 3 or Output 4 user programmable The ALARM SHUNT signal is available when access is granted This signal can be programmed to acti...

Page 2: ...SALMON GREEN GRAY BLACK VIOLET BLACK BLUE DOOR POSITION SWITCH N C REQUEST TO EXIT SWITCH N O GROUND OUTPUT 4 OUTPUT 3 GROUND SENSE REQUEST TO EXIT GROUND E1 E8 E7 E6 E5 E4 E3 E2 C NO C NC NO AUXILIARY OUTPUTS 100mA MAX TO COMMON NOT USED KEYPAD POWER WIRE HARNESS E1 E8 MAIN RELAY AUXILIARY RELAY ANTI TAMPER SWITCH BACK JP1 E1 E8 JP2 Grn Wire To earth ground CAUTION IF THE UNIT IS AC POWERED MAKE ...

Page 3: ...IGGERS A NORMALLY OPEN ALARM PANEL ZONE EXAMPLE 2 BLUE PINK SALMON OUTPUT 3 COM OUTPUT 4 COM POWER SOURCE OUTPUT 3 END OF LINE RESISTOR ALARM PANEL NO ZONE COMMON LOW VOLTAGE LAMP BLACK BLACK OUTPUT 4 EACH OUTPUT 100 mA MAXIMUM Wire Pigtail Wire Pigtail Fig 4 Basic Door Installation Wiring Sense Input RE Note The SENSE input gray wire can be programmed as either a door sense or inhibit input Both ...

Page 4: ...pen Relay 2 toggled The green indicator will light momentarily when the new code is accepted The green indicator will light when the new code is accepted If the user number already exists or an entry error has been made the red indicator will light Delete the user and re enter the new information again Note Leading zeros zeros before the code number i e 0001 do not need to be entered when programm...

Page 5: ... Alarm Shunt Output Default No Output Sets which output activates during the time access is granted Use this output ot shunt alarm contacts attached to the access door This output may be timed or toggled Press 15 Output Output Output to Activate 0 4 1 Main Relay 2 Auxiliary Relay 3 Output 3 4 Output 4 0 No Output Select Request to Exit Output Default No Output Sets which output activates when the ...

Page 6: ...the keypad STEP 2 Locate Remove jumper at JP2 Reference page 2 STEP 3 Re apply power You will get a single beep and the yellow LED will flash momentarily STEP 4 Replace jumper on JP2 THE MASTER PROGRAMMING CODE IS NOW 123456 Beep Sounds During Main Relay Default No Selects whether or not the keypad beeps during Main Relay activation Press 41 Sound Sound 1 for Yes 0 for No Solid state Output 4 On t...

Page 7: ...s visit www hagerco com for the latest Installation Instructions HAGER COMPANIES 139 Victor Street St Louis MO 63104 800 325 9995 5 750 1 375 3 000 4X Mount at holes With supplied screws and hole expansion anchors SURFACE MOUNT MOUNTING TO SINGLE GANG RECESSED OUTLET BOX 2X Mount at slots ...

Page 8: ... 9 Rev Date 7 9 21 Always visit www hagerco com for the latest Installation Instructions HAGER COMPANIES 139 Victor Street St Louis MO 63104 800 325 9995 OPTIONAL SHROUD SURFACE MOUNT WITH OPTIONAL SHROUD Part 2 679 0669 4X Mount at holes POST MOUNT WITH SHROUD 4 4 ...

Reviews: