2916 Keypad

Installation Instructions

I-EA00080

Rev 9, Rev Date: 7/9/21

Always visit www.hagerco.com for the latest Installation Instructions

HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995

The 

2916

 Indoor/Outdoor Keypad is a surface-mount digital keyless 

entry system designed for access control applications.  The backlit 
keys  are bright and easy-to-read. A heavy cast vandal resistant 
housing design with mounting plate allows the 2916  to be mounted 
on a  rugged surface or on a standard single-gang electrical box.  
  
The 2916 has a capacity of 500 users. Users can be assigned to use 
4 to 6 digit PIN codes. An authenticated access  can be programmed 
to activate one or both of the onboard relay outputs. 

The timed “anti-passback” feature prevents using the same 
credentials  twice  before a programmed waiting period has  
elapsed.

Two long lasting solid state LED indicators show the status of the 
system.  The left bi-color indicator lights red to indicate power, then 
solid green when a relay is active (access grant, etc.).  The right 
indicator flashes yellow to indicate that the keypad is in programming 
mode.

An internal sounder can be programmed to beep each time a key is 
pressed or when an output is activated.  An internal jumper sets the 
sounder volume high or low.

The 

SENSE 

input can be configured  two ways through 

programming .  When configured for “Door Sense”, the input is wired 
to a normally closed door position switch to detect when the door is 
opened or closed.  Forced entry or door ajar situations can then be 
detected. The “Auto-relock” feature can also be used  to  turn off the 
Main Relay output immediately when the door is closed after access 
has been granted to prevent “tailgating”.
When the 

SENSE 

input is configured for “Inhibit”, the input can be 

wired to a normally open “service” switch or automatic timer that will 
disable access while the switch is closed.

The 

REQUEST-TO-EXIT 

input can be wired to a normally open 

pushbutton to provide codeless activation of the Main Relay, 
Auxiliary Relay, Output #3 or Output #4 (user programmable).

The 

ALARM SHUNT 

signal is available when access is granted.  

This signal can be programmed to activate any of the relays or solid 
state outputs  to shunt alarm contacts on the access door/gate  
preventing the  triggering of an alarm when an authorized access 
occurs.

The 2916 is powered from a 12 or 24V AC or DC source. The non-
volatile EEPROM memory retains  entry codes and programming 
when power is removed.  An internal jumper is provided to reset the 
master code.  The Main Relay has a 5 Amp capacity.  The Auxiliary 
Relay has a 2 Amp capacity.  Two solid state outputs, capable of 
sinking 100 mA to common are programmable for alarm shunting, or 
to signal forced entry, door ajar, keypad lockout, request-to-exit, and 
keypad active conditions.

INSTALLATION INSTRUCTIONS

2916 Keypad

SPECIFICATIONS

Mechanical

Dimensions:   3.00" W x 5.75" H x 1.375" D

      (1.4375” wall projection)

Electrical

Input Voltage: 12/24 Volts AC or DC
Operating Current: 30 mA typical, 150 mA max

Output Ratings

   Main Relay: Form “C” 5 Amps @ 28 Volts max

     Auxiliary Relay: Form “C” 2 Amp @ 28 Volts max

Type:  Solid state outputs (Outputs #3 & #4)
Short-to-common 100 mA @ 24 VDC maximum

Environmental

Temperature: -4°F to 140°F (-20°C to 60°C)
Humidity: 5% to 95% non-condensing

FEATURES

                                                                

 

Keypad programmable

 

500 user codes

 

4 to 6 digit user codes

 

4 independent outputs

 

4 independent timers

 

2 Form C relay contacts

 

2 solid state open collector outputs

 

Program entry codes to activate one or 
two relays

 

Disable input

 

Door sense input

 

Request-to-exit/Reception input

 

Keypad tamper lockout

 

Timed anti-passback

 

Anti-tailgate

 

Two LED status indicators

 

Tactile key feel

 

Audible code entry verification

 

12V or 24V, AC or DC operation

Summary of Contents for 2916

Page 1: ...it the input can be wired to a normally open service switch or automatic timer that will disable access while the switch is closed The REQUEST TO EXIT input can be wired to a normally open pushbutton to provide codeless activation of the Main Relay Auxiliary Relay Output 3 or Output 4 user programmable The ALARM SHUNT signal is available when access is granted This signal can be programmed to acti...

Page 2: ...SALMON GREEN GRAY BLACK VIOLET BLACK BLUE DOOR POSITION SWITCH N C REQUEST TO EXIT SWITCH N O GROUND OUTPUT 4 OUTPUT 3 GROUND SENSE REQUEST TO EXIT GROUND E1 E8 E7 E6 E5 E4 E3 E2 C NO C NC NO AUXILIARY OUTPUTS 100mA MAX TO COMMON NOT USED KEYPAD POWER WIRE HARNESS E1 E8 MAIN RELAY AUXILIARY RELAY ANTI TAMPER SWITCH BACK JP1 E1 E8 JP2 Grn Wire To earth ground CAUTION IF THE UNIT IS AC POWERED MAKE ...

Page 3: ...IGGERS A NORMALLY OPEN ALARM PANEL ZONE EXAMPLE 2 BLUE PINK SALMON OUTPUT 3 COM OUTPUT 4 COM POWER SOURCE OUTPUT 3 END OF LINE RESISTOR ALARM PANEL NO ZONE COMMON LOW VOLTAGE LAMP BLACK BLACK OUTPUT 4 EACH OUTPUT 100 mA MAXIMUM Wire Pigtail Wire Pigtail Fig 4 Basic Door Installation Wiring Sense Input RE Note The SENSE input gray wire can be programmed as either a door sense or inhibit input Both ...

Page 4: ...pen Relay 2 toggled The green indicator will light momentarily when the new code is accepted The green indicator will light when the new code is accepted If the user number already exists or an entry error has been made the red indicator will light Delete the user and re enter the new information again Note Leading zeros zeros before the code number i e 0001 do not need to be entered when programm...

Page 5: ... Alarm Shunt Output Default No Output Sets which output activates during the time access is granted Use this output ot shunt alarm contacts attached to the access door This output may be timed or toggled Press 15 Output Output Output to Activate 0 4 1 Main Relay 2 Auxiliary Relay 3 Output 3 4 Output 4 0 No Output Select Request to Exit Output Default No Output Sets which output activates when the ...

Page 6: ...the keypad STEP 2 Locate Remove jumper at JP2 Reference page 2 STEP 3 Re apply power You will get a single beep and the yellow LED will flash momentarily STEP 4 Replace jumper on JP2 THE MASTER PROGRAMMING CODE IS NOW 123456 Beep Sounds During Main Relay Default No Selects whether or not the keypad beeps during Main Relay activation Press 41 Sound Sound 1 for Yes 0 for No Solid state Output 4 On t...

Page 7: ...s visit www hagerco com for the latest Installation Instructions HAGER COMPANIES 139 Victor Street St Louis MO 63104 800 325 9995 5 750 1 375 3 000 4X Mount at holes With supplied screws and hole expansion anchors SURFACE MOUNT MOUNTING TO SINGLE GANG RECESSED OUTLET BOX 2X Mount at slots ...

Page 8: ... 9 Rev Date 7 9 21 Always visit www hagerco com for the latest Installation Instructions HAGER COMPANIES 139 Victor Street St Louis MO 63104 800 325 9995 OPTIONAL SHROUD SURFACE MOUNT WITH OPTIONAL SHROUD Part 2 679 0669 4X Mount at holes POST MOUNT WITH SHROUD 4 4 ...

Reviews: