background image

– 15 –

P

ARTS

L

IST

DESIGNATOR

VALUE

PART #

ALL RESISTORS IN OHMS

R1

1.0K OHM 1/10W 1%

RM/10-1001B

R10

47K OHM 1/10W 5%

RM/10-473B

R100

10K OHM 1/10W 1%

RM/10-1002B

R101

9.09KOHM 1/10W 1% 

RM/10-9091B

R102

1M OHM 1/10W 5%

RM/10-105B

R103

10K OHM 1/10W 1%

RM/10-1002B

R104

13K OHM 1/10W 5%

RM/10-133B

R107

10K OHM 1/10W 1%

RM/10-1002B

R109

14K OHM 1/10W 1%

RM/10-1402B

R11

1.0K OHM 1/10W 1%

RM/10-1001B

R110

14K OHM 1/10W 1%

RM/10-1402B

R111

14K OHM 1/10W 1%

RM/10-1402B

R112

13K OHM 1/10W 5%

RM/10-133B

R113

10K OHM 1/10W 1%

RM/10-1002B

R114

9.09KOHM 1/10W 1%

RM/10-9091B

R12

10K OHM 1/10W 1%

RM/10-1002B

R120

10K OHM 1/10W 1%

RM/10-1002B

R121

620 OHM 1/10W 5%

RM/10-621B

R122

620 OHM 1/10W 5%

RM/10-621B

R123

1.74K OHM 1/10W 1%

RM/10-1741B

R124

RES 0 OHM 1/4W

RMP/4-0000-03

R125

RES 0 OHM 1/4W

RMP/4-0000-03

R127

10K OHM 1/10W 1%

RM/10-1002B

R129

100 OHM 1/10W 5%

RM/10-101B

R13

470K OHM 1/10W 5% 

RM/10-474B

R130

8.25K OHM 1/10W 1%

RM/10-8251B

R132

1.74K OHM 1/10W 1%

RM/10-1741B

R136

POT 5K 

RV-502Q

R137

2.61K OHM 1/10W 1%

RM/10-2611B

R14

100 OHM 1/4W 5%

RM/4-101C

R145

10M OHM 1/10W 5%

RM/10-106B

R146

10K OHM 1/10W 1%

RM/10-1002B

R147

6.81K OHM 1/10W 1%

RM/10-6811B

R15

3.3M OHM 1/10W 5%

RM/10-335B

R156

10K OHM 1/10W 1%

RM/10-1002B

R157

1.33K OHM 1/4W 1%

RM/4-1331C

R158

1.33K OHM 1/4W 1% 

RM/4-1331C

R16

4.75K OHM 1/10W 1%

RM/10-4751B

R164

8.25K OHM 1/10W 1%

RM/10-8251B

R17

10K OHM 1/10W 1%

RM/10-1002B

R18

100K OHM 1/10W 5%

RM/10-104B

R19

604K OHM 1/10W 1%

RM/10-6043B

R2

1.0K OHM 1/10W 1%

RM/10-1001B

R20

100K OHM 1/10W 5%

RM/10-104B

R21

2.2M OHM 1/10W 5%

RM/10-225B

R22

100K OHM 1/10W 5%

RM/10-104B

R23

56K OHM 1/10W 5% 

RM/10-563B

R24

1.0K OHM 1/10W 1%

RM/10-1001B

R25

10K OHM 1/10W 1%

RM/10-1002B

R26

1M OHM 1/10W 5%

RM/10-105B

R27

121 OHM 1/10W 1%

RM/10-1210B

R278

510 OHM 1/10W 5%

RM/10-511B

R28

121 OHM 1/10W 1%

RM/10-1210B

R29

KNOB 2-3 WAY CROSSOVER KN-1824-A

R29

POT QUAD 9MM 20K 

RV-203Q

R3

1.0K OHM 1/10W 1%

RM/10-1001B

R30

100 OHM 1/4W 5%

RM/4-101C

R31

300 OHM 1/10W 5%

RM/10-301B

R32

47K OHM 1/10W 5%

RM/10-473B

R33

4.75K OHM 1/4W 1% 1206

RM/4-4751C

R34

2K OHM 1/4W 1%

RM/4-2001C

R35

820 OHM 1/4W 5% 

RM/4-821C

R36

3.3M OHM 1/10W 5%

RM/10-335B

R37

10 OHM 1/10W 5%

RM/10-100B

R38

300 OHM 1/10W 5%

RM/10-301B

R39

300 OHM 1/10W 5%

RM/10-301B

R4

47K OHM 1/10W 5%

RM/10-473B

R40

20.0K OHM 1/10W 1%

RM/10-2002B

R41

4.75K OHM 1/4W 1%               RM/4-4751C

R42

47K OHM 1/10W 5%

RM/10-473B

R43

1.0K OHM 1/10W 1%

RM/10-1001B

R44

16.2K OHM 1/10W 1%

RM/10-1622B

R45

1.0K OHM 1/10W 1%

RM/10-1001B

R46

RES 28K OHM 1/4W 1%

RMP/4-2802-04

R47

2.2M OHM 1/10W 5%

RM/10-225B

R48

28K OHM 1/10W 1%

RM/10-2802B

R49

1.74K OHM 1/10W 1%

RM/10-1741B

R5

1.0K OHM 1/10W 1%

RM/10-1001B

R50

5.11K OHM 1/4W 1% 

RM/4-5111C

R51

1.74K OHM 1/10W 1%

RM/10-1741B

R52

3.3M OHM 1/10W 5%

RM/10-335B

R53

2K OHM 1/4W 1%

RM/4-2001C

R54

3.3M OHM 1/10W 5%

RM/10-335B

R55

300 OHM 1/10W 5%

RM/10-301B

R56

243 OHM 1/4W 1%

RM/4-2430C

R57

470K OHM 1/10W 5% 

RM/10-474B

R58

POT 2K TRIM

RV-202

R59

1.74K OHM 1/10W 1%

RM/10-1741B

R6

100 OHM 1/10W 5%

RM/10-101B

R60

300 OHM 1/10W 5%

RM/10-301B

R61

14K OHM 1/10W 1%

RM/10-1402B

R62

14K OHM 1/10W 1%

RM/10-1402B

R63

300 OHM 1/10W 5%

RM/10-301B

R64

14K OHM 1/10W 1%

RM/10-1402B

R65

10K OHM 1/10W 1%

RM/10-1002B

R66

1.74K OHM 1/10W 1%

RM/10-1741B

R67

1.0K OHM 1/10W 1%

RM/10-1001B

R68

100 OHM 1/4W 5% 

RM/4-101C

R69

2.0K OHM 1/10W 1%

RM/10-2001B

R7

100 OHM 1/10W 5%

RM/10-101B

R70

280 OHM 1/10W 1%

RM/10-2800B

R71

10 OHM 1/10W 5%

RM/10-100B

R72

100 OHM 1/4W 5% 

RM/4-101C

R73

10K OHM 1/10W 1%

RM/10-1002B

R74

4.75K OHM 1/10W 1% 

RM/10-4751B

R75

4.75K OHM 1/10W 1%

RM/10-4751B

R78

680 OHM 1/10W 5%

RM/10-681B

R8

POT 2K TRIM 

RV-202

R80

300 OHM 1/10W 5%

RM/10-301B

R81

300 OHM 1/10W 5%

RM/10-301B

R82

232K OHM 1/10W 1%

RM/10-2323B

R83

243 OHM 1/4W 1% 

RM/4-2430C

R84

100 OHM 1/10W 5%

RM/10-101B

R85

8.25K OHM 1/10W 1%

RM/10-8251B

R86

RES 10 OHM 1W

RM1-100-012

R9

POT 2K TRIM

RV-202

R98

8.25K OHM 1/10W 1%

RM/10-8251B

RV1

KNOB 2-3 WAY CROSSOVER KN-1824-A

RV1

DUAL 5K LINEAR

RV-502DPA

C1

10UF 16V

CER-106SM

C10

10PF 50V

CDS-100CAAA

C11

10UF 16V

CER-106SM

C12

.1UF 50V 

CYV-104

C13

CAP 3300UF 35V 

CERS-338B

C14

.47UF 50V 

CYV-474

C15

.1UF 50V

CDS-104CBBB

C16

.1UF 50V

CDS-104CBBB

C17

.1UF 50V

CDS-104CBBB

C18

.1UF 50V

CDS-104CBBB

C19

.1UF 50V

CDS-104CBBB

C2

CAP 3300UF 63V 

CERS-338E

C20

.1UF 50V

CDS-104CBBB

C21

10PF 50V

CDS-100CAAA

C22

.47UF 50V 

CYV-474

C25

.1UF 50V

CDS-104CBBB

C26

47PF 100V

CDS-470DAAA

C27

.1UF 50V

CDS-104CBBB

C28

10UF 16V 

CER-106SM

Summary of Contents for TRM10.1

Page 1: ......

Page 2: ...er s Name ________________________________________________________ Importer s Address ________________________________________________________ Type of Equipment 2 channel Audio Power Amplifier Speaker...

Page 3: ...he same three wire grounded connection It is important that the blades of the equip ment s plug be able to fully insert into the mating receptacle Never remove the round grounding pin on the plug in a...

Page 4: ...ioente requerida pra la operaci n segura de todo el equipo conectado Aun m s las extensiones deben proveer de la misma conecci n aterrada de tres hiles Es importante que el enchufe se pueda introducir...

Page 5: ...art des util isations de ce mat riel L utilisation de rallonge t d adaptateur est d consell e moins d tre en mesure de fournir la charge lectrique requise un fonctionement sans risque de tout mat riel...

Page 6: ...meisten Anwendungen v l lig ausreicht Wenn Sie Verl ngerungskabel benutzen achten Sie darauf das dies die erforderlichen Str me bertragen k nnen Benutzen Sie immer dreiadrige Verl ngerungskable 11 ZE...

Page 7: ...i impieghi L impiego di prolunghe e adattatori sconsigliato se questi non garantiscono la potenza sufficiente per i corretto fuinzionamento degli apparati connessi E alters importante che vengano semp...

Page 8: ...s are subject to change without notice AMPLIFIER SECTION TRM10 1 Free Field Frequency Response 27Hz 110Hz 2dB 25Hz 110Hz 2dB Peak Acoustic Output 112dB w music 2m 115dB w music 2m Total Harmonic Disto...

Page 9: ...sitivity 11 Low Pass Crossover 11 Phase Control 12 AC Line 13 LED Indicator 13 Break In and Warm Up 13 Cleaning and Maintenance 13 SERVICE REFERENCE PC Board Layout 14 Parts List 15 TRM10 1 TRM12 1 Fu...

Page 10: ...result in superior sound quality The amplifier features an auto turn on off circuit that eliminates the need for a conventional power switch Input sig nals can be fed into the amplifier via Balanced X...

Page 11: ...er transistors at ultrasonic frequencies This allows amplifier performance similar to trans nova which is highly stable and linear while utilizing the advantages of a non floating power supply THE RES...

Page 12: ...power handling by efficiently dissipating heat Subsonic Filter The TRM series uses a Subsonic Filter to prevent the woofer from reproducing inaudible frequencies Subsonic frequencies known as infrason...

Page 13: ...side Heatsink Front Panel View Front Panel View Rear Panel View Rear Panel View RCA Input Gain Low Pass Crossover Bal Unbal Input Switch Phase Control XLR Input AC Line Fuse 12 Subwoofer located insid...

Page 14: ...5 SCHEMATIC DIAGRAM NOTES Unless specified otherwise 1 All resistors in ohms 2 All capacitors in microfarads...

Page 15: ...6 Qualified Service Personnel Only Input Circuit Power Supply Schematic...

Page 16: ...7 SCHEMATIC DIAGRAM NOTES Unless specified otherwise 1 All resistors in ohms 2 All capacitors in microfarads...

Page 17: ...8 Qualified Service Personnel Only Output Circuitry...

Page 18: ...ire the subwoofer downward FIG 1 or fire the subwoofer directly facing for ward FIG 2 In either application keep the subwoofer cabinet at least 5 12 7 cm away from any wall INSTALLATION FIG 1 Downward...

Page 19: ...onductor being a ground drain In this configuration noise common on both phases of the signal is effectively canceled out The second method is an XLR Unbalanced Input using 2 conductor cable with the...

Page 20: ...t level the input circuit is more sensitive to the amplitude of the input signal LOW PASS CROSSOVER The Low Pass Crossover is used to set the electrical cutoff point of the subwoofer enclosure The Cro...

Page 21: ...RM10 1 TRM12 1 and the full range speakers 4 From the listening position alternate between the TRM10 1 TRM12 1 and the full range speakers and adjust the levels until they have the same acoustic outpu...

Page 22: ...for system troubleshooting The LED will illuminate GREEN if signal is present at the subwoofer s input The LED will turn off and the amplifier will go into sleep mode if signal is not present BREAK I...

Page 23: ...14 PC B OARD L AYOUT Qualified Service Personnel Only...

Page 24: ...4 821C R36 3 3M OHM 1 10W 5 RM 10 335B R37 10 OHM 1 10W 5 RM 10 100B R38 300 OHM 1 10W 5 RM 10 301B R39 300 OHM 1 10W 5 RM 10 301B R4 47K OHM 1 10W 5 RM 10 473B R40 20 0K OHM 1 10W 1 RM 10 2002B R41...

Page 25: ...PN SS 0792 Q18 XSTR MMBT3906LT1 PNP SS 0791 Q19 XSTR NPN MPSA06 SS 102A Q2 XSTR MMBT3904LT1 NPN SS 0792 Q2 Regulator LM317 WP 2350 Q21 XSTR MPS A56 SS 101A Q23 XSTR MMBT3906LT1 PNP SS 0791 Q3 Regulato...

Page 26: ...ances Buffer U3B unloads the attenuators and provides 6dB of gain with R25 and R73 PHASE CONTROL CIRCUIT The output signal of U3B goes directly to U4B if DS2 is left open 0 degrees phase shift If onl...

Page 27: ...nd Q21 drives the negative output MOSFET Q10 Local feedback components C47 and R86 help to sta bilize this output stage At low output voltages current flows to the woofer from the lower voltage rail L...

Page 28: ...stage of the detection circuit amplifies the WOOFER signal by 40dB to ensure that even the smallest input signal is detected and high pass filters it to eliminate DC offset errors This amplified sign...

Page 29: ...s remove the jumper TP1 and connect an ammeter across the exposed pins Adjust trimpot R9 fully counter clockwise before reapplying power to the unit After the Soft Start turn on has settled note the a...

Page 30: ...connect the transformer secondary molex FIG 1 6 Follow steps 1 5 in reverse order to install amplifier CAUTION Reconnect wires as indicated in diagram WOOFER REPLACEMENT 1 Remove 8 screws from woofer...

Page 31: ...than Hafler or an Authorized Hafler service center 3 Any product purchased outside the United States please contact your local dealer 4 Shipping charges to get the unit to Hafler 5 Any product which...

Page 32: ...s product is designed developed and assembled in the USA by a dedicated group of American workers The majority of the components used in the con struction of this product are produced by American comp...

Reviews: