The M5 enclosure is a textured black vinyl clad 

5/8

” thick  MDF cabinet with an internal volume of

5.3 liters and a front firing slotted port tuning the system to 70Hz. The low frequency character of the
M5  follows a classic 4th order Butterworth vented alignment with smooth response extending down
well below system tuning. Small panel size and strategically placed internal bracing reduces wall flex-
ing and mid-band resonance. High cabinet rigidity also improves low frequency mid-bass coupling.

The M5 tweeter uses a proprietary 25mm silk dome and exponential horn waveguide combination.
The 133mm (5

1/4

”) M5 mid-bass driver is a custom designed and manufactured speaker specific to

this new Hafler monitor. This woofer uses a polypropylene cone with a nitrile rubber edge for fast,
efficient low frequency damping and uniform piston control. The cone’s polypropylene material is
mineral loaded and adds the required stiffness to maintain a smooth response character well past the
system’s crossover point. The increased cone rigidity also helps minimize inter-modulation distortion
(IMD) components. IMD at normal playback levels is not just an audible distraction it’s a contributor
to listening fatigue. 

The linear characteristic of the multi-rolled flat spider and the nitrile rubber edge also ensures low lev-
els of harmonic distortion (THD). High magnetic linearity is achieved by using a long 32mm (1

1/4

”)

diameter voice coil set in a computer optimized magnet structure. The 4.2 lb magnet assembly is
completely shielded for use near video monitors or other CRT devices. The M5 mid-bass driver is
carefully designed and constructed to be both thermally and mechanically capable of handling the
200-watt system power rating.

Design Features

Summary of Contents for M5

Page 1: ...51 4 Reference Monitor 51 4 Reference Monitor...

Page 2: ...h frequencies to the tweeter and low frequencies to the woofer The circuit also incorporates optical protection for overload protection and a 0dB 3dB tweet er pad to match the tweeter level to the mid...

Page 3: ...ICATIONS 3 PERFORMANCE SPECIFICATIONS 4 Frequency Response Graph 4 Horizontal Polar Response Graph 4 Impedance Graph 5 Impulse Graph 5 Cumulative Spectral Decay Plot 5 TECHNICAL DESIGN FEATURES 6 INST...

Page 4: ...er Surround Full Magnetic Shielding Cabinet 0 19 cu ft 5 3 liters Black Textured Vinyl on 5 8 MDF Front Firing Vent Power Rating 20 200 Watts Program Sensitivity 89dB w 2 83 vrms 1m Nominal Impedance...

Page 5: ...4 Frequency Response 1m on axis Horizontal Polar Response Performance Specifications...

Page 6: ...5 Impedance Graph Impulse Graph Cumulative Spectral Decay Plot Performance Specifications...

Page 7: ...edge for fast efficient low frequency damping and uniform piston control The cone s polypropylene material is mineral loaded and adds the required stiffness to maintain a smooth response character we...

Page 8: ...resulting in inadequate stereo imaging Aiming the monitors toward you and spaced equally like a triangle Fig 2 provides the best imaging and produces the flattest fre quency response If you frequentl...

Page 9: ...e center 3 Any product purchased outside the United States please contact your local dealer 4 Shipping charges to get the unit to Hafler 5 Any product which has had the serial number defaced altered o...

Page 10: ...e used in or around water such as a bathtub sink or swimming area Also the equipment should not be used in areas prone to flooding such as a basement 8 CLEANING The equipment should be cleaned only as...

Page 11: ...OS QUE REQUIEREN DE SERVICIO Los equipos Hafler deben ser llevados a servicio por personal califi cado cuando A Objetos l quido hayan sido introducidos der ramado en el equipo B El equipo haya sido e...

Page 12: ...ON Le mat riel Hafler devrait tre r vis par des personnes qualif es de service apr s vente lorsque A De objets sont tomb s sur le mat riel ou des liquides s y son dispers s ou B Le mat riel a t expos...

Page 13: ...sollte nur von qualifizierten Service Technikern instand gesetzt werden wenn A Eine Fl ssigkeit in das Ger t eingedrimgem ist B Das Ger t Regen ausgesetzt wurde C Das Ger t nicht mehr ordnungsgem b fu...

Page 14: ...zionato in aree convenienti per una corretta ventilazione Prestare attenzione che sia consentita circo lazione d aria attorno e dentro il cabinet 7 ACQUA E POLVERE L apparato deve essere posizionato l...

Page 15: ...14 Notes...

Page 16: ...This product is designed developed and assembled in the USA by a dedicated group of American workers The majority of the components used in the construction of this product are produced by American co...

Reviews: