7
A BDE
F G
struction, RF remote system
Installation
o
connect the power supply and
the motor unit to the remote re-
ceiver. 2 different plug sizes
make this connection only possi-
ble to make in the right way
o
after having connected the plugs,
the blue light will be lit
o
push the emitter buttons and the
motor unit will move up and
down
o
for stopping the motion one of
the buttons need to be pushed
Learning
o
if the remote receiver does not respond when pushing the emitter buttons, reset the
receiver. After that, code the emitter and receiver together again
Coding
o
push the learner button on the receiver for less than 1 sec.
o
push one of the emitter buttons
o
the red light will start flashing
o
push one of the emitter buttons again and the red light will turn off
o
the units now are coded together with a unique code
Reset
o
push and hold down the learner button on the receiver for 10 sec. (will be reset when
the red light turns off).
External rocker switch
o
the external rocker switch can be connected to the receiver, if a fixed operation unit is
required.
Trouble shooting
o
check the plug connections
o
check whether the blue light is on
o
reset the receiver and make a new coding
o
always test the lift on the manual rocker switch
o