H
D
E
1
1
/2
018
73
2.2
9
.1
28
42
If no return or disposal agreement exist, recycle disassembled components:
• Scrap metals.
• Recycle plastic components.
• Dispose of other components sorted by nature of the material.
See chapter "2.8 Environmental protection" on page 30.
9. Storage
9.1 Storage of
packages
Store packages under the following conditions:
• Do not store outdoors.
• Store in a dry and dust-free place.
• Do not expose to aggressive media.
• Protect against sun exposure.
• Avoid mechanical vibrations.
• Storage temperature: –25 – +70 °C
• Relative humidity: max. 90 %, not condensed.
10. Technical data
10.1 Connection and
power values
10.2 Ambient
conditions during
operation
In some cases, instructions for storage may be located on
the package, which go beyond the requirements listed here.
Follow these accordingly.
Specification
Value
Unit
Voltage
12 – 24
V DC
Tolerance
±
15
%
Current consumption, maximum
(with 12 V)
0,2
A
Power consumption, maximum
3
W
Safe-keeping
1
A
Lead type (all terminals)
0.13 – 0.52
mm
2
Specification
Value
Unit
Operating temperature
-25 – +70
°C
Relative humidity, maximum
(not condensed)
10 – 95
%
Degree of protection (front)
IP 65
Degree of protection (rear)
IP 44
ins-src-732.29.128.book Seite 42 Dienstag, 20. November 2018 10:27 10