8
INSTALLATION
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
RECIRCULATION VERSION AIR OUTLET
ELECTRICAL CONNECTION
•
To install a •
Ø
120 mm air exhaust connection, insert
the reducer flange 9 on the hood body outlet.
•
Fix the pipe in position using sufficient pipe clamps
(not supplied).
•
Remove possible charcoal filters.
•
Cut a hole
Ø
125 mm in any shelf that may be posi
-
tioned over the hood.
•
Insert the reducer flange 9 on the hood body outlet.
•
Connect the flange to the outlet on the shelf over the
hood by using a flexible or rigid pipe
Ø
120 mm,
•
Fix the pipe in position using sufficient pipe clamps
(not supplied).
•
Fix the air outlet grid 8 on the recirculation air outlet
by using the 2 screws 12e (2,9x9,5) provided.
•
Ensure that the activated charcoal filters have been
inserted.
•
Connect the hood to the mains through a two-pole switch having a contact gap of at
least 3 mm.
•
When opening the sliding carriage for the first time after installing the hood, pull it out
briskly until it clicks.
When installing the ducted versionm connect the hood to
the chimney using either a flexible or rigid pipe •
Ø
150 or
120 mm, the choice of which is left to the installer.