Esento Marine 8-12 Installation, Commissioning & Operating Manual
Approved Document Ref: UI-ESEN12MAR-01 Issue 8.0
19
SETUP & PROGRAMMING
PROGRAMMING OPTIONS INDEX
Option/Setting
Description
Code(s)
Page
View History
View the last 40 events
1111
20
Set Fault Buzzer Volume
Set the fault buzzer volume to high or low
2224
21
Clear All Disablements
Remove all disablements which have been set for any zone,
sounder circuit, output or delay
1121
21
Initialise Factory Settings
Restores all programming, test modes and disablements back to
factory default settings
1113
21
Muster Alarm Signal / VDR card
Set zones and RESOUND button to activate a muster alarm,
Muster alarm Synchronisation,Set presence of VDR card
1222
22
Panel Wide Settings
• Change/remove keypad access code
•
Set number of repeater panels on system
•
Set time for panel delay timer
•
Disable battery monitoring/UPS mode
•
Setup internal PCB config (add/remove zone cards)
• Change network/repeater comms monitoring type
•
Set number of output cards
•
Inhibit muted tone beeps
•
Inhibit network alarms & faults for panel
•
Set number of network slave panels on system (Master Panel
only)
•
Inhibit network slave panel fire & fault buzzer
2123
24
Zone Function Settings
•
Set zone to latching or non latching
•
Set zone to old B.S (short circuit = fire)
•
Set zone for use with MTL5061 I.S. barrier
•
Set zone to silent mode (provides visual & audible indication at
the panel but no sounder operation)
• Turn off priority alarm feature for zone
• Turn off detector removal monitoring for zone
•
Set detector removal monitoring type for zone (Schottky or
Zener diode detector bases)
3121
30
Dependancy Modes (False Alarm
Management)
Set panel & zones to dependancy mode A, B or C
2124, 2114, 2134
32
EN54 Sounder Resound Options
Set zones to not resound alarms after an initial fire condition
1114
34
Delays to Outputs
Apply delays to outputs in response to selected zones
2323
35
Input Functions
Change the default functions of the Class Change and Alert inputs 4141
36
Output Programmability &
Miscellaneous
Set panel outputs to be programmable, switch on fault latching,
invert fault output
4142
37
Panel Output Zonal Responses
Set how each output and sounder circuit responds for each zone
(off, continuous or pulsing)
4242, 4342
38
Panel Output Functional Options
Change the default panel output & sounder circuit responses to
‘Silence Alarms’, ‘Evacuate’, ‘Class Change’, ‘Alert’ and ‘Delay’
4244, 4344
40
Network Output Responses
Set local output & relay responses to network fires
4224
42
Network Sounder Responses
Set local sounder cct responses to network fires
4324
43
Comms PCB Output Functional
Options
Change the default comms PCB o/p responses to ‘Silence
Alarms’, ‘Evacuate’, ‘Class Change’, ‘Alert’ and ‘Delay’
4343
44
System Diagnostics Mode
Tests system PCB config setup for fault diagnosis
3114
45
Repeater Programming
Repeater panel setup & programming
4443