background image

 

Before First Use

 

Please read through the instructions 
carefully  before  using  the  unit  and 
carefully  note  the  safety  advice. 
Always keep this manual accessible 
to any users of the drill. 
 

Area of Application 

The  control  unit  can  be  set  up  in  a 
cabinet  or  can  be  used  as  a 
portable unit (e.g. in a carry case). It 
is suitable for the following scopes: 
 

 

foot care/manicure

 

(milling, trimming and polishing)

 

Attention:  Additional  spray  or 
suction  might  have  to  be  in 
operation  during  foot  care  in  your 
country. 

 

 dental technique/dental laboratory 

(Milling,  trimming  and  polishing 
work at plaster casts and models) 

Do  not  use  this  unit  for  dentist 
purposes,  i.e.  working  directly 
on the patient. 

 

 industry 

(grinding,  milling  and  polishing 
works) 

Installation Site 

The  installation  of  the  workroom 
must correspond to any regulations 
according to your country laws. Set 
up  the  control  unit,  so  that  the 
ventilation  slits  are  not  covered  or 
blocked,  and  the  exhaust  air  can 
escape well.  
 
The  drill  and  the  charging  unit  may 
only  be  operated  in  confined 
spaces.  Temperature  rising  of  the 
housing is normal during operation. 
Although  the  unit  should  never  be 
covered,  nor  be  located  near 
heating  devices  or  in  direct  sun 
impact. 
 

Summary of Contents for Xantos-Nail 0872

Page 1: ...art 0872 FB 04 182 Rev 5 Date 21 01 2019 Manual Xantos Nail ...

Page 2: ...g to Know the Unit 8 Before First Use 9 Area of Application 9 Installation Site 9 Application 10 Starting up and Operating the Unit 10 Clamping the Bur Tool 10 Setting up the Speed 10 Maintenance Care 11 Handling Instructions 12 Troubleshooting 13 Technical Data 15 ...

Page 3: ... not blocked and the extracted air can escape well Only switch on the unit if the handpiece rests secured in the handpiece holder or if you hold it safely in your hand To avoid the risk of electrocution only connect the device to the mains power supply If you pull the power plug it will stop the connection to the mains power supply Set up the unit so that the power plug is always accessible The po...

Page 4: ...illing unit with suction or spray technique Wear a nose and mouth protection Always follow the safety instructions provided by the manufacturer of the materials being formed and used For safety reasons wear goggles during the treatment Ensure that the patient s foot and the handpiece are held firmly in place during the operation To prevent injury work with extreme caution on the foot of the patien...

Page 5: ...y with the appliance Before using the equipment assure that the tool can be pushed far enough into the chuck Test this with a dipstick and clean the handpiece if necessary the inserted tool sits properly in the chuck and will not cant jam while clamping it the tool is approved for using it at the max speed see manufacturer s instructions or only use the speed required by the instrument the tool is...

Page 6: ... yourself This is only to be accomplished by an authorized specialist The mains cable may also only be changed by the manufacturer or an authorized specialist Never remove the housing especially not while the equipment is plugged into the socket since some components are under electric voltage Any unauthorized or improper handling e g trying to repair the unit of the equipment will immediately nul...

Page 7: ...ting tool e g bur capper etc first Then handle the cleaning of the tool according to the instructions of its manufacturer Remove tissue remains by wiping off the unit with a mildly moistened paper cloth Afterwards clean all surfaces with disinfection cloth e g Mikrozid AF Tücher of Schülke and Mayr ...

Page 8: ...8 Getting to Know the Unit 1 speed display 2 LED 3 increase speed 4 change direction of rotation 5 decrease speed 6 ON OFF button 8 ...

Page 9: ...ry dental technique dental laboratory Milling trimming and polishing work at plaster casts and models Do not use this unit for dentist purposes i e working directly on the patient industry grinding milling and polishing works Installation Site The installation of the workroom must correspond to any regulations according to your country laws Set up the control unit so that the ventilation slits are...

Page 10: ...e hand Turn the ring spot B clockwise with your free hand until it snaps Now the chuck is opened Insert the bur until the end of the chuck Screw the ring B counter clockwise until it snaps Check if the bur sticks well It sticks well when you cannot pull it out Please do not turn on the unit while the chuck is opened This can damage the motor and the electronic devices For security reasons only cha...

Page 11: ...eekly cleaning every 20 working hours Screw off the top pg 10 and brush off the loose parts with the added brush Hold the handpiece that way that the top points downward the table to avoid that more dirt can enter the inside of the handpiece ...

Page 12: ...e when you not working with the handpiece always remove the bur tool from it Always make sure that you do not let the handpiece fall down or exposes it to any shocks The ball bearings and the motor could be damaged by this Only work with tools which are flawless Do not work with tools which are bent or out of balance whose shaft is worn out or are rusty Working with faulty tools will cause a stron...

Page 13: ...ck the position of the spring on the carbon The spring should be in the middle of the carbon The carbon is a wearing part and has to be replaced after it is worn out A pair of carbons was added to your delivery Then also check the second carbon If the handpiece becomes hot In case the handpiece should become hot or the noise level extraordinary loud apparently the ball bearings of the front part o...

Page 14: ...14 Troubleshooting Assembly Drawing More manuals for repair workshops you will find at http hadewe online de guides index htm Attend to fitting position ...

Page 15: ...e in household refuse Respect your local disposal regulations Declaration of Conformity We declare under our sole responsibility that the products 0872 and to which this declaration relates are conform to the following standards or normative documents 2014 30 EU directive EMC 2014 35 EU low voltage directive hadewe GmbH Grambartstraße 10 30165 Hannover Germany Safety Check A safety check must be d...

Page 16: ...hadewe GmbH Grambartstraße 10 30165 Hannover Germany info hadewe de www hadewe de ...

Reviews: