![HADEF EEE Installation, Operating And Maintenance Instructions Download Page 15](http://html1.mh-extra.com/html/hadef/eee/eee_installation-operating-and-maintenance-instructions_4425412015.webp)
5.52.707.00.01.02
15
12.3.2
Disassembly of the brake
Disassembly is performed in reverse order to the assembly.
12.3.3
Adjusting the air gap
View "X" on the brake.
1 Loosen the locking screws (6) by half a turn.
2 Turn the cap screws (8) into the magnetic body
(9) anti-clockwise.
3 By turning the locking screws (6) clockwise,
move the magnetic body (9) towards the
anchor plate (10) using a feeler gauge until
nominal air gap “a” is reached (see table).
4 Unscrew the cap screws (8) from the magnetic
body clockwise.
5 Tighten the locking screws (6).
6 Check the air gap again and re-adjust if
necessary.
Illustration 14
Pos: 17.1 /1_HADEF/13-PRÜFUNG/*Ü1*/#. Kapitel - Prüfung @ 0\mod_1173264087196_52.docx @ 507 @ @ 1
13 Inspection
Pos: 17.2 /1_HADEF/13-PRÜFUNG/Wiederkehrende Prüfung/00.GÜ (nur motorische Geräte) @ 2\mod_1276587258148_52.docx @ 14490 @ @ 1
13.1
General Overhaul for motor-driven units
The validated, national accident prevention regulations must be observed and the measures to reach "safe
working periods (S.W.P.)" according to FEM 9.755.
After the "theoretical working time D" has been elapsed, the owner/user must take motor driven devices out
of operation and effect a General Overhaul.
Further use of the equipment is only allowed after a licensed qualified person has proofed
that further use is possible without doubt
and
the conditions for further use have been determined
These conditions have to be written down in the test book.
The owner/user is responsible to make sure that these conditions are observed.
Pos: 17.3 /1_HADEF/13-PRÜFUNG/Wiederkehrende Prüfung/01.Wiederkehrende Prüfung @ 0\mod_1175675257580_52.docx @ 3164 @ @ 1
13.2 Periodic
checks
Independently from the regulations of the individual countries, lifting devices must be checked at least yearly
by a qualified person or licensed qualified person regarding its functional safety.
Pos: 17.4 /1_HADEF/13-PRÜFUNG/Krane/Krane/Inspektionsintervalle @ 2\mod_1287564895035_52.docx @ 16488 @ @ 1
13.3 Inspection
intervals
at
putting into
operation
daily
checks
Inspection
every
3 months
Inspection
every
12 months
Check screw connections.
X
X
check socket pins and plugs
X
Check the wheels for wear
X
Check the function of the brake (electric and pneumatic
cranes)
X X
lubricate the teeth of the wheels
X
Gear
see chapter "maintenance"
inspection of the equipment by an expert
(periodic inspection)
X
Pos: 18.1 /1_HADEF/14-WARTUNG/*Ü1*/#. Kapitel - Wartung @ 0\mod_1172647693186_52.docx @ 409 @ @ 1