10
5.52.194VA.00.01.03
8.2 Load
chain
Before commissioning the load chain must be aligned and oiled.
For the first commissioning of motorized hoists, chain oil is supplied with the delivery.
Move safety note and fixing wire away from the chain.
CAUTION!
Do not use grease for lubrication of load chain.
Without lubrication, manufacturer's warranty and/or liability will be void.
NOTICE!
Continuous, thorough lubrication will increase the life of the chain considerably.
9 Safety
check
Before putting into service initially or when putting back into service, it must be checked whether:
All fastening screws (if existent), socket pins, flap socket and safety devices are tightened and secured.
The chains are correctly placed, oiled and in good condition.
10 Functional
test
10.1
Checks before the initial start-up
Lifting gear
Load chains must not be twisted.
Lubricate the load chain with gear oil or suitable chain lubricant before first loading.
Trolley drive
The open-lying teeth of the trolley drive must be lubricated.
Hand gear for hand geared trolley
Ensure correct fit of the hand chain, it must not be twisted and must hang freely.
10.2 Functional
test
Lifting gear
Check lifting and lowering functions, initially without a load.
Then check the brake function under load. The load must be securely held.
Trolleys
Carefully move the trolley to the end positions and check the positions of the end stops.
11 Maintenance
11.1 General
All monitoring, servicing and maintenance operations are to ensure correct functioning of the equipment;
they must be effected with utmost care.
Only “qualified persons” may do this work.
Servicing and maintenance work must only be done when the hoist is not loaded.
Records must be kept of all test results and measures taken.
11.2 Monitoring
The monitoring and servicing intervals stated are valid for operation under normal conditions and single-shift
operation. In case of severe operating conditions (e.g. frequent operation with full load) or special
environmental conditions (e.g., heat, dust, etc.), the intervals must be shortened correspondingly