Remedy
36
5.52.541.00.01.01
16 Remedy
Pos: 20.2 /1_HADEF/16-ABHILFE/Kettenzug/02.Tabelle - Standard - P @ 1\mod_1193297520879_52.docx @ 8195 @ @ 1
Problem
Cause
Remedy
Pneumatic air motor is not running
Operating pressure/quantity of air is too low
Check connection to mains supply
After prolonged standstill
see maintenance of the pneumatic motor
Motor runs, load is not lifted
Slipping clutch is slipping through (overload)
Reduce the load to nominal load
Slipping clutch is slipping through (at < rated
load)
Adjust the slipping clutch
Hoist motor is running – chain does not lower
Blockage due to chain link pointing sideways in
the chain container
Select larger chain container so that the chain
can be properly arranged before the inlet
Lubricate the chain.
motor does not brake or has excessive after-
running*
brake linings are worn
exchange complete brake lining carrier
*some trolleys have got self-locking gears and no brake that may be the cause for mistakes
Pos: 21.1 /1_HADEF/17-AUßERBETRIEBNAHME/*Ü1*/#. Kapitel - Außerbetriebnahme @ 0\mod_1172648336045_52.docx @ 417 @ @ 1