16
5.52.179.00.01.09
irrelevant whether the 4 minutes are continuous (i.e., in case of very high lifting heights) or are made in
intervals.
The lifting tackle or the load must be securely attached to the hook and be seated at the bottom of the
hook. The safety catch must always be closed.
DANGER!
It is not allowed:
pulling loose of stuck loads, dragging of loads and inclined pulling is not allowed.
in explosive atmosphere, except the unit is especially modified for it and marked by an indication label
In reactor containment vessels.
to transport people
The device is not suitable for use on stages and in studios
persons must not stand under a suspended load
9
Commissioning
9.1
General
Should the unit be used in Germany:
Please observe the validated, national accident prevention regulations.
For other countries:
Inspections as above. Please observe the national rules and regulations and the instructions in this manual!
NOTICE!
Hoists up to 1000 kg capacity and without motor-
driven trolleys of hoisting unit must be tested by a “qualified
person” before putting into operation for the first time.
Hoists of 1000 kg capacity and up or with more than one motor-driven hoist movement; i.e. lifting and trolley
movement, must be tested by a “licensed qualified person” before putting in operation.
An exception is “hoists ready for operation” acc. validated national regulations with EU-declaration of
conformity.
Definition “qualified person” (former expert)
A “qualified person” has learned, due to occupational training and experience and the job that the person has
done, the skills needed to tests
the material for one’s work.
Definition “licensed qualified person” (former approved expert)
A “licensed qualified person” has, due through special occupational training, knowledge about testing of the
material for one’s work and knows the national accident prevention regulations and other prescriptions and
technical regulations. This person must test the material for one’s work regularly with regard to design and
kind of use. The license will be given to qualified person be the approved supervision authorities (ZÜS).
9.2
Power supply
9.2.1
Mains connection
Hoist motor technical data can be found it in the "Technical data" chapter.
The following tables show the assignment of the fuses at 400 Volt 3-phase current.
Select connection cross-sections as per VDE 0100.
Put sleeves on the ends of the cables.
Insert the connection cable into the connection plug without strain.
Secure lines as per VDE 0100.
9.2.2
Control line connection
Pendant with cable and plug-in connection. Plug-in before use.
Any changes of the power supply cable must only be effected by qualified personnel.