background image

Inductive Probe 8398 

 

 

 

17

 
 
 

Reference Material 

Immersion 

(m)

Flange 

Immersion 

setting 

Adapter required 

08335=A=5005 PP 

0.5  DN65 

PVC 

Adjustable 

08398=A=1014 

(H = 150 mm) 

08335=A=5010 PP 

DN65 

PVC 

Adjustable 

08398=A=1014 

08335=A=5015 PP 

1.5  DN65 

PVC 

Adjustable 

08398=A=1014 

08335=A=5020 PP 

DN65 

PVC 

Adjustable 

08398=A=1014 

08398=A=6005 PP 

0.5 

DN50 

PP Fixed 

08398=A=6010 PP 

DN50 

PP Fixed 

08398=A=6015 PP 

1.5 

DN50 

PP Fixed 

08398=A=6020 PP 

DN50 

PP Fixed 

08398=A=6605 PP 

0.5  DN50 

PVC 

Adjustable 

08398=A=6610 PP 

DN50 

PVC 

Adjustable 

08398=A=6615 PP 

1.5  DN50 

PVC 

Adjustable 

08398=A=6620 PP 

DN50 

PVC 

Adjustable 

08350=A=1105 PP 

0.5 

Clip  08398=C=0300 

(H = 130 mm) 

08350=A=1110 PP 

Clip  08398=C=0300 

08350=A=1115 PP 

1.5 

Clip  08398=C=0300 

08350=A=1120 PP 

Clip  08398=C=0300 

08878=A=1500 STAINLESS 

1.5 

(*) 

Adjustable  08398=C=0500 

 

(*): No flange, to be used with 08878=C=1600 support 

 
 
 
 

Summary of Contents for POLYMETRON 8398

Page 1: ...DOC024 52 93026 POLYMETRON Model 8398 Inductive Probe User Manual 06 2015 Edition 5...

Page 2: ......

Page 3: ...ring and control instruments do not fall within the scope of the RoHS Directive however Hach Lange has taken the decision to adopt the recommendations in the Directive as the target for all future pro...

Page 4: ......

Page 5: ...Compliance 7 4 PROBE START UP 7 4 1 Cable connection 7 4 2 Use with a 8921 conductimeter 8 4 3 Use with a 9125 conductimeter 9 5 PROBE CALIBRATION 9 6 INSTALLATION PRECAUTION 11 7 ACCESSORIES 13 7 1...

Page 6: ...measurements The main uses are as follows Determination of solution concentrations in place cleaning regeneration of resin in water processing plants surface treatment Accurate interface control in co...

Page 7: ...ent dependent solely upon the geometry of the probe and termed cell or K constant expressed in cm 1 R K C S cm 1 In order to allow the comparison between measurements made at different temperatures th...

Page 8: ...etic field that generates an electrical current in the solution x The secondary or receiver coil detects the size of the weak current induced by the movement of ions in the solution The absence of con...

Page 9: ...e chemical resistance is summarised in the table 9 WARNING PEEC is not resistant to high concentrations of oxidative acids nitric and sulphuric acid 70 etc In the case of probe 8398 5 one must conside...

Page 10: ...ean directives 89 336 CEE and 73 23 CEE modified by directive 93 68 CEE 4 PROBE START UP 4 1 Cable connection WARNING Fit the DN50 clamping nut or the immersion rod onto the probe before wiring Make t...

Page 11: ...he transmitter s front panel 4 screws x On the rear of the front panel there are two circuit boards Remove the first of these two circuit boards 4 screws x At the rear of this printed circuit board ca...

Page 12: ...ate your temperature sensor Submerge the probe in a solution for approximately 10 min raise the temperature of this solution using a thermometer accurate to r 0 1 C if possible Set the transmitter to...

Page 13: ...1 13 06 mS cm c f Ch 2 1 Process calibration 9125 only During the first calibration of the chain process calibration must be performed at two distinct points probe in air then in the control solution...

Page 14: ...nnelled to within less than 10 mm thus allowing measurements to be made without disturbance in DN65 conduits It is also possible to perform measurements in DN50 conduits using our DN65 DN50 converging...

Page 15: ...the conduit s flow direction thus avoiding the influence of flow rate and to perform the self cleaning of this opening For optimal operation the POLYMETRON marking should be positioned in the conduit...

Page 16: ...429 500 510 EPDM joint for 2 clamp 6 581 100 510 2 stainless steel ferrule to weld Min DN65 1 2 6 08398 A 0510 Kit with 2 stainless collar 2 EPDM joint 2 stainless ferrule Min DN65 1 2 3 08398 A 7500...

Page 17: ...Inductive Probe 8398 14 7 2 Probe 8398 3 DIN 11851 DN50 dairy connection model 08398 A 3000 APPLICATION FREE FLOW...

Page 18: ...DN65 1 7 10 08398 A 5330 Kit with DN50 stainless screw VITON DN50 joint PVDF ferrule to weld H 23 mm Min DN65 1 2 4 08398 A 6000 Kit with DN50 stainless screw EPDM DN50 joint DN65 50 T piece DN50 1 2...

Page 19: ...model specially adapted to immersion measurements it is supplied as standard with an EPDM sheet gasket an optional Viton joint ref 08398 C 3438 is also available along with the stainless steel 1 G scr...

Page 20: ...P 0 5 DN50 PP Fixed 08398 A 6010 PP 1 DN50 PP Fixed 08398 A 6015 PP 1 5 DN50 PP Fixed 08398 A 6020 PP 2 DN50 PP Fixed 08398 A 6605 PP 0 5 DN50 PVC Adjustable 08398 A 6610 PP 1 DN50 PVC Adjustable 0839...

Page 21: ...C Temperature sensor Pt100 R 3 4 1 2 Secondary coil R 5 6 1 2 Primary coil R 3 5 f Coil electrical insulation o If the checks performed do not generate any erroneous resistance values the probe can be...

Page 22: ...this symbol may not be disposed of in European public disposal systems after 12 August of 2005 In conformity with European local and national regulations EU Directive 2002 96 EC European electrical e...

Page 23: ...0 0 0 x 0 0 Sodium hydroxide 10 40 0 0 0 0 0 0 0 0 x 0 x 0 0 0 0 0 Ammonia 10 30 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Ammonium chloride Sat 0 0 0 0 0 0 0 0 0 Zinc chloride 50 0 0 0 0 0 0 0 0 Iron chloride...

Page 24: ...ium hydroxide 10 40 0 0 0 0 x x 0 0 x x 0 0 0 0 0 0 Ammonia 10 30 0 0 0 0 0 0 0 0 0 0 0 Ammonium chloride Sat 0 0 0 0 0 0 x x x Zinc chloride 50 0 0 0 0 0 0 x x x Iron chloride 50 0 0 0 0 0 0 Sodium s...

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ...32 orders hach com www hach com HACH LANGE GMBH Willst tterstra e 11 D 40549 D sseldorf Germany Tel 49 0 2 11 52 88 320 Fax 49 0 2 11 52 88 210 info de hach com www de hach com HACH LANGE S rl 6 route...