Figure 4  Display overview

1   

Calibration icon

4   

Battery icon

7   

Calibration standard(s) expected

2

2   

Lock icon

5   

Parameter value

8   

Temperature

3   

Parameter

6   

Calibration standard(s) measured for
last calibration (low, medium, high)

Table 1  Display icons

Icon Description

Shows the battery power level. Flashes when the battery power is less than 10%.

Shows when the lock feature is on. When the lock feature is on, the parameter value on the display does not change.
Push   to set the lock feature to on or off.

Shows when the tester is in calibration mode or when a calibration is due. If "?" shows next to the calibration icon, the
last calibration was not successful.

Keypad description

Figure 5

 shows the keypad. 

Table 2

 gives the key descriptions.

Figure 5  Keypad overview

1   

Power key

2   

Calibration/Settings key

3   

Lock key

2

Shows during calibration

6

Summary of Contents for Pocket Pro CondLR

Page 1: ...User Manual DOC022 52 80396 Pocket Pro CondLR CondHR 1...

Page 2: ...equential damages resulting from any defect or omission in this manual The manufacturer reserves the right to make changes in this manual and the products it describes at any time without notice or ob...

Page 3: ...plier for instructions on how to return end of life equipment producer supplied electrical accessories and all auxiliary items for proper disposal Certification Canadian Radio Interference Causing Equ...

Page 4: ...tion the receiving antenna for the device receiving the interference 3 Try combinations of the above Product overview The Pocket Pro conductivityLR tester and conductivityHR tester measure the conduct...

Page 5: ...ical type and are inserted in the correct orientation Do not mix new and used batteries WA RNING Fire hazard Battery substitution is not permitted Use only alkaline batteries Install the four AAA alka...

Page 6: ...y power is less than 10 Shows when the lock feature is on When the lock feature is on the parameter value on the display does not change Push to set the lock feature to on or off Shows when the tester...

Page 7: ...standard CondLR tester One or two auto recognition calibration standards 1 Set the power to on 2 Remove the cap from the sensor 3 Push to go to calibration mode The auto recognition standard s the te...

Page 8: ...perature compensation factor linear 0 00 to 9 99 per C default 2 00 per C The correction factor may need to be identified experimentally For example the factor for ultrapure water is 4 55 per C and th...

Page 9: ...rature range of the tester Contact technical support as necessary Note The tester can still be used if a temperature sensor failure has occurred but without automatic temperature compensation Battery...

Page 10: ...ach com www hach com HACH LANGE GMBH Willst tterstra e 11 D 40549 D sseldorf Germany Tel 49 0 2 11 52 88 320 Fax 49 0 2 11 52 88 210 info hach lange de www hach lange de HACH LANGE S rl 6 route de Com...

Reviews: